Wells MOD-100TD-AF Installation Manual

ELECTRICAL
MODELS VOLTS WATTS AMPS PHASE WIRING
MOD-100TD/AF MOD-100TD/AF 240
208 1240
1650
6.0
6.9 SINGLE
SINGLE 12 AWG Cu
FIELD
GAUGE
12 AWG Cu 75°C
TEMP.
RATING
75°C
INCHES
(MM)
CUTOUT DETAILS PRODUCT DIMENSIONS
14
(356)
23 1/2
22
(559)
2 1/4
4 1/8 (105)
(57)
(597)
INSTALLATION INSTRUCTIONS
BUILT-IN FOOD WARMERS
WITH AUTO WATER FILL
MOD-100TD/AF
TOP CUTOUT
12 7/8
(327)
3 1/8 (79)
FRONT PANEL CUTOUT
5
(127)
CLEARANCES
MINIMUM CLEARANCE REQUIRED
UNIT TO THE NEAREST SURFACE
BACK SIDE BOTTOM FRONT
1 1
(25)
(25) (171)
6 3/4
4 1/8
(105)
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
1. Required installation clearances: Wooden and Metal Installation: DO NOT install closer than 4 1/8 inches to front wall, 1 inch to back and side walls, and 6 3/4 inches to surface below the unit. If the control box is located below the unit, the front clearance may be 1 inch.
2. Unit shall be accessible for servicing from the bottom.
3. If storage is to be used underneath the unit, it is recommended that a baffle be placed 8 1/2 inches below
the unit to avoid contact with elevated temperatures.
4. For water and waste connections: This appliance is to be installed to comply with the applicable federal, state, or local plumbing codes.
TO FABRICATE:
1. Lay out cutout dimensions on countertop and front apron.
2. Lay out and fabricate control panel holes in counter apron using the control box as a template.
3. Cut out holes.
TO INSTALL: IMPORTANT - DO NOT disconnect lead wires from the
Master Control Panel when making installation.
1. Tilt and pass Control Panel and electrical box through the countertop cutout, then through the apron cutout. Lower modular section into countertop cutout and position. RECOMMENDATION: Before final seating of modular section to countertop, apply a bead of silicone adhesive/sealant to the underside of gray gasket material supplied on the mounting flange.
2. From underneath, insert screwdriver into slots in Wellslock frame and twist ears outward (clockwise) as required to secure flange tightly to countertop.
3. Mount Control Box to apron cutout as shown in drawing.
WELLS/BLOOMFIELD * VERDI, NV
1/4 INCH EXTERNAL NPT WATER LINE CONNECTION
4. Mount Control Panel onto electrical box using the screws supplied.
TO PLUMB:
1. Connect 1/2" drain connection to suitable drain line.
2. Connect 1/4"NPT water supply to Solenoid valve in Outlet Box. Note: Maximum pressure 120 psi, maximum temperature 120°F. A backflow preventor is incorporated in the unit, between the water fill solenoid and pan. Local codes may require an additional vacuum break device. (Not provided by Wells). Device must be installed in accordance with local codes and authorities having jurisdiction.
TO WIRE:
1. Final connection is accomplished by bringing proper power supply leads (see 'WIRING REQUIREMENTS' label) through conduit knockout to terminal block supplied within the Master Control Panel. Check nameplates for voltage and phase.
NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND
WARMER FLANGE
GASKET
SOLENOID
WATER SUPPLY 1/4 NPT
7 3/8 (187)
14 3/4
(375)
14
(356)
6 1/4 (159)
1/2 INCH INTERNAL NPT
ELECTRICAL CODES.
WELLSLOK
SCREWDRIVER
COUNTERTOP
9 3/4
(248)
1 3/4
(44)
MASTER CONTROL
IMPORTANT: MOUNT APPLIANCE SO THAT THE CONTROL PANEL IS LOCATED TO THE
PANEL
FRONT OF THE FIXTURE.
303438-1 REV (-)