ELECTRICAL
INSTALLATION INSTRUCTIONS BUILT-IN MODULAR WARMERS
MOD-100 SERIES (T, TD)
PHASEMODELS WATTSVOLTS AMPS
MOD-100
MOD-100 900208 4.3 SINGLE
MOD-100
MOD-100T 1650120 13.8 SINGLE 14 AWB Cu
MOD-100T
MOD-100T 1650240 6.9 SINGLE 12 AWB Cu
MOD-100EUT 220-240 1650 6.9 SINGLE 1.5 mm
ALL MODELS WITH A "D" SUFFIX HAVE THE SAME ELECTRICAL SPECIFICATIONS AS THE STANDARD MOD-100 AND MOD-100T MODELS
120
240
208
1200
1200
1240
10.0 SINGLE
5.0 SINGLE 12 AWB Cu
6.0 SINGLE 12 AWB Cu
FIELD WIRING GAUGE
14 AWB Cu
12 AWB Cu
CUTOUT DETAILS
3 1/8
20 3/4
4 1/8
(105)
12 3/4
(324)
TOP CUTOUT FRONT PANEL CUTOUT
(527)
(79)
4 7/8
(124)
5
(127)
CLEARANCES
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE.
FRONTBOTTOMSIDEBACK
4 1/86 3/411 (105)(171)(25)(25)
TEMP.
RATING
90°C
75°C
75°C
90°C
75°C
75°C
2
90°C
INCHES
(MM)
6 7/8
(175)
13 3/4
(349)
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
1. Required Installation Clearances: Wooden and Metal Installation: DO NOT install closer than 4 1/8 inches to front wall, 1 inch to back and side walls, and 6 3/4 inches to a surface below the unit. If the control box is located below the unit, the front clearance may be 1 inch.
2. Unit shall be accessible for servicing from the bottom.
3. If storage is to be used underneath the unit, it is recommended that a baffle be placed 8 1/2 inches below the unit to avoid contact with elevated temperatures.
TO FABRICATE:
1. Layout "cutout" dimensions on countertop and front apron.
2. Layout and fabricate control panel holes in counter apron using the control box as a template.
3. Cut out holes.
4. Unit shall be accessible for servicing from the bottom.
TO INSTALL: IMPORTANT - DO NOT disconnect "lead wires" from the Master Control Panel when making installation.
1. Tilt and pass Control Panel and electrical box through the countertop cutout, then through the apron cutout. Lower modular section into countertop cutout and position. RECOMMENDATION: Before final seating of modular section to countertop, apply a bead of silicone adhesive/sealant to underside of gray gasket material supplied on the mounting flange.
2. From underneath, insert screwdriver into "slots" in Wellslok frame and twist "ears" outward (clockwise) as required to secure flange tightly to countertop.
3. Mount Control Box to apron cutout as shown in drawing.
4. Mount Control Panel onto electrical box using the screws supplied.
TO PLUMB:
1. Warmers with a 'D' suffix are supplied with individual 1/2'' female N.P.T. drains.
2. Connect to suitable drain line.
TO WIRE:
1. Final connection is accomplished by bringing proper power supply leads (see 'wiring requirements' label) through conduit knockout to wire leads supplied within the Master Control Panel. Check nameplates for voltage and phase.
2. Do not connect to a circuit operating at more than 150 volts to ground. (240 volt models only).
NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND
ELECTRICAL CODES.
WARMER FLANGE
GASKET
WELLSLOK
SCREWDRIVER
COUNTERTOP
WELLS/BLOOMFIELD * VERDI, NV
21 3/4
(552)
2 1/4
(57)
6 1/4
(159)
9 3/4
(248)
1/2 INCH
5 7/8
(149)
IMPORTANT: MOUNT APPLIANCE SO THAT THE CONTROL PANEL IS LOCATED TO THE FRONT OF THE FIXTURE.