Installation
Dressing Nook and 34" Integrated Panel
With Diagnostic System
Unpacking Notes
• Concealed Damage. If there should be damage of
such nature that it could not be detected until the
goods were unpacked, have the Transportation
Company's Agent come AT ONCE and inspect them.
Require them to give you a "concealed" bad order
report stating the condition of the goods when examined. It is their duty to do this and you should INSIST
upon it.
• If the Above Instructions are Complied With, we
shall cheerfully render all possible assistance in
establishing claims against the Transportation Company for loss and damage in transit.
• We Do Not Accept Goods Returned For Credit,
Exchange, Repairs, or for any other reason, unless
you have first communicated with us and secured our
written permission.
Installation
NOTE
The Dressing Nook and Integrated Panel are mounted to
the wall using steel mounting brackets (provided with
units). Wall anchors and drywall screws are also provided
to secure the mounting brackets to the wall. Figures 1
thru 5 are suggested mounting configurations and
locations only.
1. Using the customer or room layout drawing, determine
where the Dressing Nook and / or Integrated Panel are
to be located. See Figure 1 for the suggested room
layout.
2. Check clearance required for placing a side chair
beside the Dressing Nook. A minimum of 24 in. (61
cm) is required for the Midmark 429 or Ritter 129 Side
Chair. See Figure 2.
¨
NOTE
This note applies to steps 5 thru 7. When securing
mounting brackets to a wall with metal studs, use sheet
metal screws in place of drywall screws and when
securing mounting brackets to a masonry / concrete block
wall, use masonry screws in place of drywall screws and
wall anchors.
5. Place the mounting bracket in position on wall and
6. Install a wall anchor in each hole. Install a screw in
mounting brackets is critical for installation.
7. Attach mounting brackets to the wall using wall anchor
8. Test each mounting bracket for strength.
9. Mount the instruments to the Integrated Panel as
Instructions
mark the locations of all fasteners. Remove the
mounting bracket and drill a 3/8 in. hole where all wall
anchors are to be used; four holes per mounting
bracket if a wall stud is not located and three holes per
mounting bracket if a wall stud is located.
each wall anchor and tighten far enough to secure the
wall anchor in place. Then, remove all screws from the
wall anchors.
EQUIPMENT ALERT
The 61-7/16 in. (156 cm) minimum
dimension between the Dressing Nook
screws. Level each mounting bracket before securing
to the wall.
follows using Figure 4 or 5 to properly position the
instruments:
Position the Aneroid Blood Pressure Unit on the single
screw provided and then secure top of unit in place
using two additional screws provided. Install (hang)
the remaining instrument assemblies on the preinstalled mounting screws.
NOTE
If the locations of the units differ from what is shown in
Figure 2, then bracket locations shown in Figure 3 must be
changed accordingly.
3. Measure and mark the mounting locations of the
mounting brackets on the wall. See Figure 3.
4. Locate and mark the location of studs in reference to
mounting bracket; an electronic stud finder may be
useful.
© Midmark Corporation - 1997
10. Lift the Dressing Nook and / or Integrated Panel onto
their mounting brackets.
Sheet 1 of 2
EXAM
26 3/4"
10 7/16"
67 7/8"
INTEGRATED
PANEL
DRESSING
NOOK
FLOOR
WALL
61 7/16"
71 7/8"
56 1/4"
12"
34"
TABLE
INTEGRATED
PANEL
DRESSING
NOOK
STOOL
CASEWORK
SIDE
CHAIR
8'-0"
10'-0"
FIGURE 1. SUGGESTED ROOM LAYOUT
4"
INTEGRATED
PANEL
DRESSING
NOOK
12"
24"
Min.
MA318401
FIGURE 3. MOUNTING BRACKET
POSITIONING ON WALL
Wall Transformer For
Otoscope/Ophthalmoscope
1
6
0
0
4
1
1
8
0
0
2
1
2
Tycos
0
0
0
0
1
0
8
2
4
0
2
0
6
0
6
0
2
8
4
0
0
2
3
0
0
0
1
WALL
Aneroid Blood
Pressure Unit
FIGURE 4. INSTRUMENT LOCA TION FOR A
76792 INTEGRA TED PANEL
KleenSpec
Dispenser
MA318301
MA417800
FLOOR
FIGURE 2. DRESSING NOOK / INTEGRATED
PANEL POSITIONING ON WALL
For questions or information regarding the medical
instruments on the Integrated Panel, contact Welch
Allyn, Inc. at 4341 State Street Road, Skaneateles
Falls, NY 13153. [Tel: 315-685-4560]
© Midmark Corporation - 1997
Midmark Corporation, Versailles, Ohio 45380 U.S.A.
937-526-3662 TELEX 288007 FAX 937-526-5542
MA318501
Wall Transformer For
1
6
0
0
4
1
1
8
0
0
2
1
Tycos
0
0
1
0
8
0
6
0
8
4
0
0
2
3
0
0
0
1
Aneroid Blood
Pressure Unit
Otoscope/Ophthalmoscope
2
0
0
2
4
0
2
6
0
2
Sure Temp 4
Unit
FIGURE 5. INSTRUMENT LOCA TION FOR A
76791 INTEGRA TED PANEL
R
Sheet 2 of 2
003-0898-00 Rev . C (9/00)
KleenSpec
Dispenser
MA417700