Weber 42390 User Manual

®
SUMMIT
BUILT-IN LP TANK ENCLOSURE KIT
SILVER A - SILVER D - GOLD D
#
42390
Summit® Built-In LP Tank Enclosure Kit
(Model #: 21287)
THESE ACCESSORIES MAY BE PURCHASED SEPARATELY.
YOU MUST READ THIS OWNERS GUIDE
BEFORE OPERATING YOUR GAS GRILL
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open fl ames.
3. Open lid.
4. If odor continues, keep away from the appliance and immediately call your gas supplier or your fi re department.
Leaking gas may cause a fi re or explosion which can cause serious bodily injury or death, or damage to property.
WARNING
1. Do not store or use gasoline or other fl ammable liquids or vapors in the vicinity of this or any other appliance .
2. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
WARNING: Follow all leak-check
procedures carefully in this manual prior to barbecue operation. Do this even if the barbecue was dealer-assembled.
NOTICE TO INSTALLER: These instructions must be left with the owner and the owner should keep them for future use.
THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.
WARNING: Do not try to light this
appliance without reading the “Lighting Instructions” section of this manual.
42390 US 10/01/05
LP
2
Failure to follow the Dangers, Warnings and Cautions contained in this Owner’s Manual may result in serious bodily injury or death, or in a fi re or an explosion causing damage to property.
Do not store a spare or disconnected liquid propane cylinder under or near the barbecue.Improper assembly may be dangerous. Please carefully follow the assembly instructions in this
manual.
Do not operate the Weber® gas barbecue if there is a gas leak present. Do not use a fl ame to check for gas leaks.Combustible materials should never be within 24 (60.96cm) inches of the top, bottom, back or sides of
your Weber® gas barbecue.
Do not put a barbecue cover or anything fl ammable on, or in the storage area under the barbecue.Your Weber® gas barbecue should never be used by children. Accessible parts of the barbecue may be
very hot. Keep young children away while it is in use.
You should exercise reasonable care when operating your Weber® gas barbecue. It will be hot during
cooking or cleaning and should never be left unattended, or moved while in operation.
Liquid propane gas is not natural gas. The conversion or attempted use of natural gas in a liquid
propane unit or liquid propane gas in a natural gas unit is dangerous and will void your warranty.
Do not attempt to disconnect any gas fi tting while your barbecue is in operation.Keep any electrical supply cord and the fuel supply hose away from any heated surfaces.Do not use this Weber® tank enclosure kit unless all parts are in place. The unit must be properly
assembled according to the instructions outlined in the “Assembly Instruction” section of the Owner’s Guide.
DANGERS & WARNINGS
DANGER
WARNINGS
LIQUID PROPANE GAS UNITS ONLY:
Use the regulator that is supplied with your Weber® Tank Enclosure Kit. Do not attempt to disconnect the gas regulator or any gas fi tting while your barbecue is in operation. A dented or rusty liquid propane cylinder may be hazardous and should be checked by your liquid
propane supplier. Do not use a liquid propane cylinder with a damaged valve.
Although your liquid propane cylinder may appear to be empty, gas may still be present, and the
cylinder should be transported and stored accordingly.
If you see, smell or hear the hiss of escaping gas from the liquid propane cylinder:
1. Move away from liquid propane cylinder.
2. Do not attempt to correct the problem yourself.
3. Call your fi re department.
WARRANTY
3
OPERATING
WARNING: Only use the Weber® Tank Enclosure Kit outdoors in a well-ventilated area. Do not use in a garage, building, breezeway or any other enclosed area.
®
WARNING: Your Weber
Tank Enclosure Kit shall not be used under an unprotected combustible roof or overhang. WARNING: Your Weber
®
Tank Enclosure Kit is not intended to be installed in or on recreational vehicles and/or boats. WARNING: Keep any electrical supply cord and the fuel supply hose away from any heated surface. WARNING: Never store an extra (spare) LP cylinder under or near the Weber® gas barbecue. WARNING: Keep the ventilation openings of the cylinder enclosure free and clear of debris. WARNING: Turn off the gas at the LP gas supply cylinder when the outdoor cooking gas appliance is not in use. WARNING: Never store an outdoor cooking gas appliance indoors unless the LP cylinder is disconnected and removed from the outdoor cooking gas appliance. WARNING: LP Cylinders must be stored outdoors out of the reach of children and must not be stored in a building, garage, or any other enclosed area. WARNING: The LP pressure regulator and hose assembly supplied with the Weber® Tank Enclosure Kit must be used. Replacement LP pressure regulators and hoses must be obtained from Weber-Stephen Product Co.
WARRANTY
Weber-Stephen Products Co. (Weber) hereby warrants to the ORIGINAL PURCHASER of this Weber® gas grill that it will be free of defects in material and workmanship from the date of purchase as follows:
when assembled and operated in accordance with the printed instructions accompanying it. Weber may require reasonable proof of your date of purchase. THEREFORE, YOU SHOULD RETAIN YOUR SALES SLIP OR INVOICE. This Limited Warranty shall be limited to the repair or replacement of parts that prove defective under normal use and service and which on examination shall indicate, to Weber’s satisfaction, they are defective. Before returning any parts, contact the Customer service representative in your region using the contact information sheet provided with your manual. If Weber and approves the claim, Weber® will elect to replace such parts without charge. If you are required to return defective parts, transportation charges must be prepaid. Weber® will return parts to the purchaser, freight or postage prepaid. This Limited Warranty does not cover any failures or operating diffi culties due to accident, abuse, misuse, alteration, misapplication, vandalism, improper installation or improper maintenance or service, or failure to perform normal and routine maintenance, including but not limited to damage caused by insects within the burner tubes, as set out in this owner’s manual. Deterioration or damage due to severe weather conditions such as hail, hurricanes, earthquakes or tornadoes, discoloration due to exposure to chemicals either directly or in the atmosphere, is not covered by this Limited Warranty.
There are no other express warrants except as set forth herein and any applicable implied warranties of merchantability and fi tness are limited in duration to the period of coverage of this express written Limited Warranty. Some regions do not allow limitation on how long an implied warranty lasts, so this limitation may not apply to you. Weber® is not liable for any special, indirect or consequential damages. Some regions do not allow the exclusion or limitation of incidental or consequential damages, so this limitation or exclusion may not apply to you. Weber® does not authorize any person or company to assume for it any other obligation or liability in connection with the sale, installation, use, removal, return, or replacement of its equipment; and no such representations are binding on Weber®. This Warranty applies only to products sold at retail.
WEBER-STEPHEN PRODUCTS CO. Customer Service Center 1890 Roselle Road, Suite 308 Schaumburg, IL 60195 USA
www.weber.com
®
®
confi rms the defect
All Parts, 5 years
4
ASSEMBLY
TYPICAL 20 LP PROPANE GAS SUPPLY INSTALLATION
We strongly recommend that you use the Summit® Built-In Tank Cabinet (#21280) for installations using a 20 lb LP cylinder, mounted remotely in an “island” structure. The Summit® Built-In Tank Cabinet is a CSA listed accessory for installing a remote mounted 20 lb LP cylinder, in an “island” structure. Summit® Built-In Tank Cabinet has a hose and regulator assembly and gas connections, for connecting a remote mounted LP cylinder to the Summit® Built-In gas grill. The hose and regulator is listed as a required part of the CSA listed Summit® Built-In gas grill.
The Summit® Built-In Tank Cabinet also meets the requirements for venting, tank retention and separation of the LP cylinder from a heat source as outlined in the ANSI Standard for Outdoor Cooking Gas Appliances, Z21.58/ CSA 1.6 for LP enclosures. The Summit® Built-In Tank Cabinet has its own installation guide. If you do not use the Summit® Built-In Tank Cabinet, you need to hire a licensed contractor or licensed plumber and they need to follow the requirements described in the ANSI Standard for Outdoor Cooking Gas Appliances, Z21.58/CSA 1.6 for LP enclosures. The requirements described in the Standard for Outdoor Cooking Gas Appliances, Z21.58/CSA 1.6. are as follows; A remote enclosure for an LP gas cylinder shall be ventilated by openings at both the upper and lower levels of the cylinder. This shall be accomplished by one of the following:
a). One side of the remote LP cylinder enclosure shall be completely
open; or
b). If the remote LP cylinder enclosure is designed to have four sides,
a top and a bottom, ventilation is required for the remote LP cylinder enclosure;
1). There should be at least two ventilation openings, (a hole or group of holes, for the purpose of ventilation) in the sidewalls of the island structure. The openings should be located within 5 inches (127mm) of the top of the enclosure. The ventilation openings should be equally sized and spaced at a minimum of 90 degrees, and be unobstructed. The openings shall have a total free open area of not less than 20 square inches. (This relates to1 square inch of ventilation area, per pound of stored fuel capacity).
2). Ventilation openings (a hole or group of holes, for the purpose of ventilation) should be provided at fl oor level. The ventilation openings should have a total free area of not less than 10 square inches. (This relates to 1/2 square inch of ventilation area, per pound of stored fuel capacity). There should be at least two ventilation openings if the ventilation openings at fl oor level are in the sidewall. The ventilation openings should be within 5 inches (127mm) of the fl oor. The ventilation openings should be of equal size and be spaced at a minimum of 90 degrees, and should be unobstructed.
3). The minimum size of the ventilation hole (s) should not be less than 1/4 inch.
4). The ventilation openings in the sidewalls should not allow venting into the empty or “hollow” area of the “island”. If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure, the gas should not be allowed to vent or migrate into the empty or “hollow” area of the “island”. Ventilation openings in the sidewalls of the enclosure should only communicate with the outside of the “island” structure, so
c). If the remote LP cylinder enclosure has four sides, a top and a
2). At least one ventilation opening (a hole or group of holes, for the
d). The remote LP cylinder enclosure should be constructed with non-
e). There should be a minimum of 2 inches (50.8mm) between the
f). The LP cylinder valve should be readily accessible for hand
If your, licensed contractor or licensed plumber, builds an LP cylinder enclosure following the guidelines in the ANSI Standard for Outdoor Cooking Gas Appliances, Z21.58 CSA 1.6, you need to order kit number (#21287), which will contain the hose and regulator assembly, mounting bracket for the regulator, connection fi ttings and LP tank bracket for retaining the LP cylinder that must be used with the Summit hose and regulator in the kit (#21287) is listed as part of the CSA listed Summit® Built-In gas grill.
that the gas can dissipate outside of the “island” structure.
bottom, and is intended for installation in a built-in “island” enclosure;
1). At least one ventilation opening (a hole or group of holes, for the purpose of ventilation) needs to be on one side of the enclosure that communicates with the outside of the “island” structure. If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure, the gas should not be allowed to vent or migrate into the empty or “hollow” area of the “island”. Ventilation openings should only communicate with the outside of the “island” structure, so that the gas can dissipate outside of the “island” structure. The ventilation opening should be located within 5 inches (127mm) of the top of the enclosure, and should have a total free area of 20 square inches. (This relates to 1 square inch of ventilation area, per pound of stored fuel).
purpose of ventilation) needs to be on one side of the enclosure that communicates with the outside of the “island” structure, at the bottom. If a gas leak should occur or the LP cylinder should vent in the LP cylinder enclosure, the gas should not be allowed to vent or migrate into the empty or “hollow” area of the “island”. Ventilation openings should only communicate with the outside of the “island” structure, so that the gas can dissipate outside of the “island” structure. The ventilation opening should be located within 5 inches (127mm) of the bottom of the enclosure, and should have a total free area of 10 square inches. (This relates to 1/2 square inch of ventilation area, per pound of stored fuel).
3). The minimum size of the ventilation hole (s) should not be less than 1/4 inch.
combustible materials. The remote LP cylinder enclosure should isolate the LP cylinder from the burner compartment, so that it provides shielding from radiation, be a fl ame barrier and provide protection from foreign material such as hot drippings.
ground and the fl oor of the remote LP cylinder enclosure.
operation. A door on the remote LP cylinder enclosure to gain access to the LP cylinder valve is acceptable, provided it is non­locking and can be opened without the use of tools.
®
Built-In gas grill. The
Loading...
+ 8 hidden pages