Wayne-Dalton C-2400 User Manual

S E C T I O N A L D O O R S Y S T E M
C-2400
W A Y N E - D A L T O N C O M M E R C I A L D O O R S Y S T E M S
C-2400
SECTIONAL DOOR SYSTEMS
STRONG,VISUALLY APPEALING DOORS FOR MODERATE COMMERCIAL APPLICATIONS
The Wayne-Dalton C-2400 steel sectional door, available in a variety of sizes, is an excellent value. Featuring nominal 24-gauge ribbed steel sections, the C-2400 is available with a number of lite and insulation options.
• NOMINAL 24-GAUGE STEEL CONSTRUCTION
• STANDARD SIZES UP TO 20'2"WIDE & 16'1"HIGH
• VALUE PRICED CHOICE
• DESIGNED FOR MODERATE COMMERICAL APPLICATIONS
SECTIONAL DOOR SYSTEMS
C-240 0
TheWayne-Dalton C-2400 Steel Sectional Door is designed and built to ensure an economical, trouble-free long life for moderate commercial use. Available with an embossed finish in white or brown or a white smooth finish, the exterior of the C-2400 features a ribbed surface for increased strength and added visual appeal. Unique box-stile design with full 2" thickness and 3" width, plus tongue-and-groove construction, add vertical stability and strength. The stiles are continuously bonded to the skin surface with high strength adhesive, resulting in the strongest possible unit.
Materials & Construction
Wayne-Dalton's C-2400 steel sectional doors feature pre-finished interior and exterior skins on nominal 24-gauge hot-dipped galvanized steel sections roll-formed to a full 2" thickness for ultimate strength and durability. 3" wide fully­fitted boxed stiles are adhered with adhesive, preventing rust and leakage associated with rivets. Standard bottom door seal along with optional seals on the perimeter and between sections greatly reduce air leakage, adding to the thermal efficiency of the building.
Additional options include insulation and weather stripping that provide a U-value of 0.13 and an R-value of 7.60; factory installed vision lites or aluminum full view sections; electric operator; and special engineering to meet windload requirements.
Contact Wayne-Dalton for additional sizes and colors.
Color and Finish Options
White Smooth FinishBrown Smooth Finish*
Operation Options
• Chain Hoist Operation
• Motor Operation
Performance Options
• High Cycle Spring (25K,50K,100K)
• 3"Track Option
• Solid Shafts
• PerimeterWeatherseal
Window Options
Safety Options
• Broken Cable Devices
• Safety Edges
• Safety Photo Eyes
Special Application Options
• SpecialTrack Designs
• Mullions
Brown Embossed Stucco Finish*
*Note: Portland plant only offersWhite Smooth Finish. Contact your customer ser vice rep for availability to your location.
White Embossed Stucco Finish*
Vision Lites allow for visibility while maintaining security
www.wayne-dalton.com/commercial
Aluminum full view sections allow for maximum natural light and visibility
STANDARD SIZES UP TO:
20' 2" WIDE & 16' 1" HIGH CALL FOR ADDITIONAL SIZES
ENERGY EFFICIENCY VALUES:
U = 0.13 R = 7.60
WINDLOAD:
MEET OR EXCEED ANSI/DASMA 102-2003 IN ACCORDANCE WITH ASTM E-330-70.
BEST APPLICATIONS:
- Economy
- Windload performance
General Operating Clearances
Headroom*** Sideroom** Depth Into Room Center Line of Springs
Type 2" track 3" track 2" track 3" track 2" & 3" track 2" track 3" track
Standard Lift Manual12"R 121⁄2-17" NA Opening Height +12" NA
Standard Lift Manual15"R 141⁄2-20" 151⁄2-21" Opening Height +13" Opening Height +14"
Standard Lift Motor Oper. 12"R 15-191⁄2" NA 41⁄2"5
Standard Lift Motor Oper. 15"R 15-191⁄2" 18-231⁄2" Opening Height +13" Opening Height +14"
High Lift Manual
High Lift Motor Oper. 24" One Side
Vertical Lift Manual 12"R 41⁄2"5
Vertical Lift Motor Oper. 12"R 24" One Side
Low Headroom Manual* 6-141⁄2" 6-141⁄2" Opening Height +20" - 26"
Low Headroom Motor Oper.* 81⁄2-17" 81⁄2-17" Opening Height +66"
Door Height
+12"
Door Height
+20"
6" 9"
Opening Height +18"
1
2" Opening Height +12" NA
Opening Height +66"
Opening Height – Lift +30"
1
2"
Opening Height +18"
Opening Height
1
2"
+Lift +6
Double Door Height
Opening Height
+Lift +7
+13"
Does Not Apply
1
2"
Panel/Section Selection Guide
Door Section and Lite Selection Door Height and Section Selection
DoorWidth No. Panels Max. No.Windows Door Height No.Sections
Up to 9'2" 22Up thru 8'1" 4
9'3" to 12'2" 338'2" thru 10'1" 5
12'3" to 16'2" 4410'2" thru 12'1" 6
16'3" to 19'2" 5512'2" thru 14'1" 7
19'3" to 20'2" 6714'2" thru 16'1" 8
For Larger Sizes – See Model C-24
Track Selection Guide
Standard Lift High Lift
(break-away is standard, straight incline is available)
Roof Pitch (standard or high lift)
*Note: Rear mount torsion requirements shown on chart.See
drawings for front mount torsion clearances.
**Note: 8” sideroom required,one sidefor doors having chain
hoist. 24" side room required,one side for doors having jackshaft operators.
***Note: Clear headroom is based on cable size so please contact
factory for specific headroom for your door.
Vertical Lift Low Headroom
(rear mount torsion)
Low Headroom (front mount torsion)
www.wayne-dalton.com/commercial
SECTIONAL DOOR SYSTEMS
C-240 0
PART I – GENERAL
1.01 Section Includes
1.02 RelatedWork
1.03 Reference Standards
1.04 Quality Assurance
1.05 Systems Description
1.06 Submittals
1.07 Delivery, Handling, Storage
Note to specifiers: Words in parentheses indicate frequently specified and highly recommended options.
A. Sectional overhead doors [manually] [motor] operated
with accessories and components.
A. Opening preparation,miscellaneous or structural
steel work,access panelsfinish or field painting are in the scope of work of other trades and divisions of these specifications.
A. ANSI/DASMA 102 – American National
Standards Institute [A216.1] Specifications for sectional overhead doors published by Door & Access Systems ManufacturersAssociation International in bulletin102-1990.
B. ASTM A123 – Zinc [hot-dipped galvanized]
coatings on iron and steel products.
C. ASTM A216 – Specifications for sectional
overhead type doors.
D. ASTM A229 – Steel wire, oil-tempered for
mechanical springs.
E. ASTM A-653-94– Steel sheet,zinc-coated
[galvanized] by the hot-dipped process, commercial quality.
F. ASTM E330 – Structural performance of
exterior windows,curtain walls,and doors by uniform static air pressure difference.
G. ASTM E413-87 – Sound transmission class.
Acoustical performance value = 23 per. J.
H. ASTME1332-90– Outdoor-indoor
transmission class. Acoustical performance value = 19.
A. Sectional overhead doors and all accessories and
components required for complete and secure installations shall be manufactured as a system from one manufacturer.
A. Sectional Overhead Door:Type:
Model C-2400
B. Mounting:Continuous angle mounting for [steel]
[wood] jambs [bracketmounting for wood jambs]
C. Operation:[manual push-up][chain hoist] [motor]
[motor withchain hoist] D. Material:Galvanized steel withpolyester finish paint E. Insulation:Optional [polystyrene] [polyurethane]
A. Shop Drawings:Clearly indicate the following:
1. Design and installation details to withstand standard windload.
2. All details required for complete operation and installation.
3. Hardware locations.
4. Type of metal and finish for door sections.
5. Finish for miscellaneous components and accessories.
B. Product Data:Indicating manufacturer’s product
data,andinstallation instructions.
A. Deliver products in manufacturer’s original
containers,dry, undamaged,seals and labels intact.
B. Store and protect products in accordance with
manufacturer’s recommendations.
1.08 Warranty
A. Standard manufacturer’sTENYEAR warranty
againstcracking,splitting or deterioration due to rust-through.
PART I I – PRODUCTS
2.01 Manufacturer
A. Wayne-Dalton or approved equal Model C-2400
insulated sectional overhead doors of steel construction complete as specified in this section and as manufactured by Wayne-Dalton Corp.
2.02 Materials
A. Door Sections:Shall be ofroll formed steel typewith
box shaped 20 ga.[intermediate and end stile construction] and calculated materials“R”- value of
7.60 [optional] in accordance with industry guidelines.
1. Exterior Skin:Structural quality,hot-dipped galvanized steel, with [embossed stucco] [smooth] finish nominal 24 ga.with baked-on polyester primer and [white] [brown] polyester finishcoats with [smooth][non-repeating randomstucco texture] and 4 deep pinstripes.
2. Insulation:Cavity shall be filled withlaid-in-place [polyurethane] [expanded polystyrene] and covered with [vinyl] [ 0.015” minimum embossed steel] heldin place with polymer clips.
B. Track:Track design shall be [standard lift] [high lift]
[vertical lift] [low headroom].Vertical mounting angles shall be hot-dipped galvanized.Track size shall be [2"] [3"].Vertical track shall be graduated to provide wedge type weathertight closing with continuous angle mounting for [steel] [wood] jambs,andshall be fully adjustable to seal door at jambs [bracket mount for wood].Horizontal track shall be reinforced with continuous angle of adequate lengthand gauge to minimize deflection.
Note: Horizontal track applies to standard lift,high lift, low
headroom and follow-the-roof designs only.
C. Hardware:Hinge and RollerAssembly:
1. Hinges and brackets shall be made from hot­dipped,galvanized steel.
2. Track rollers shall be case-hardened inner steel races with 10-ball [2"][3"] rollers.
3. All factoryauthorized attachments shall be made at locations indicated.
D. Counterbalance:
1. Springs shall be torsion type,low-stress,helical wound,oil-tempered spring wire to provide minimum [10,000 standard] [25,000] [50,000] [100,000] cycles of use,on continuous steel [solid].
2. Spring fittings and drums madeof die cast,high strength aluminum.
3. Pre-formed galvanizedsteel aircraft cable shall provide a minimum of a 5:1safety factor.
2.03 Operation
A. Operation shall be [manual push-up] [chain hoist]
[motor][motor with chain hoist].
Note: Manufacturer does not recommend chain hoists or
jack shaft operators on the following track applications.
• 15" radius standard lift with roof pitch less than2:12
• Hi-lift less than 24"
• Hi-lift between 12" – 23" withroof pitch
less than1:12
• Low headroom track
Specialchain hoist assemblies (usinga trolley rail) are available for the above track systems.
2.04 Locks
A. Locks shall engage the right-hand vertical track
and utilize [an interior side lock] [standard size rim cylinder].
2.05 Weatherstripping
A. Doors shall be equippedwith vinylbulb shaped astragal
as standard on the bottom section. Optional joint,top head,and jambseals are available.
2.06 Glazing
A. Optional.
2.07 Windload
A. Windload – per DASMA 102-2003 and as required by
local codes.
PART III – EXECUTION
3.01 Installation
A. General:
1. Install doorsin accordance withmanufacturer’s instructions and standards.Installation shall be by an authorizedWayne-Daltonrepresentative.
2. Verify that existing conditions are ready to receive sectional overhead door work.
3. Beginning of sectional overhead door work means acceptance of existing conditions.
B. Install door complete with necessary hardware, jamb
and head mold strips,anchors,inserts,hangers,and equipment supports in accordance with final shop drawings,manufacturer’s instructions,and as specified herein.
C. Fit,align and adjust sectional overhead door assemblies
level and plumb for smooth operation.
D. Upon completion of final installation,lubricate,test and
adjust doors to operate easily, free from warp,twist or distortion and fitting for entire perimeter.
Note: Architect may consider providing a schedule when
more than one sectional overhead door or opening type is required.
3.02 Materials (See note above.)
Specifications and technical information also available at www.arcat.com, SpecWizard™, and Sweets.com®.
Distributed By:
For technical information, visit:
www.wayne-dalton.com/commercial
© 2007 Wayne-Dalton Corp. • One Door Drive • Mt. Hope, Ohio 44660 • 800-764-1457
Mt. Hope, OH • Dalton, OH • Trail, OH • Pensacola, FL • Portland, OR
Printed in U.S.A. Item #332545 Revised 9/2007