Wayne-Dalton AKBAR 89 User Manual

0 (0)
Wayne-Dalton AKBAR 89 User Manual

AKBAR 89SERIES UL-LABELED* FIRE DOORS

For easier door specifications or product questions call our Consulting Service 1-866-499-6781.

Akbar 89 fire doors are a convenient and practical solution to safety and protection. Designed to accommodate optional operation methods including powered closing and testing. Akbar 89 fire doors have a 3 or 4-hour label rating for masonry and steel (minimum 316") jambs. Also available are the 34 hour and 112 hour label ratings for non-masonry walls with fire rated drywall over minimum 16 guage steel or wood studs.

For use on interior openings and recommended for use on exterior openings which may later become interior in future building expansion.

Original counterbalance spring tension is maintained up to 85% after automatic closure; if the door is raised for any reason, it will automatically close again.

Safety governor retards the speed of automatic closing to under 2' per second. Minimizes possibility of accidents and prevents impact on sills, rebound or jamming of slats—a UL requirement for automatic fire doors.

WayneGuardFire Door Release Systems (optional) provide the ideal protection you want—and need—for both people and property.

Optional Operation Methods:Manual Lift-Up—Curtain is raised or lowered via lift handles mounted on curtain bottom bar. Interchangeability—All Akbar 89 manually operated fire doors are designed to accommodate future motor, chain or crank operation.

Recommended Options For Fire Doors Larger Than 80 Sq. Ft.:

Chain Hoist—Curtain is raised or lowered by hand chain through reduction gearing on end of counterbalance assembly.

Crank—Curtain is raised or lowered via awning-type crank and operates through shaft and reduction gearing on end of counterbalance assembly.

Motor—Curtain is raised or lowered by operators, which are activated by conveniently located pushbuttons and other devices. Motor operators can be field applied to any existing Akbar 89 door.

Available with Standard (curved) or Optional (flat) 2" slats or 3" slats.

Fire Lites: For situations where visibility and/or light are required. Not available on F.M. rated fire doors.

Optional Welded Guides: As a matter of convenience and/or to speed up installation of the Akbar 89 fire door, the guides may be welded to steel jambs. This eliminates the need to drill and tap mounting holes, saving installation time and cost. Not available on F.M. rated fire doors.

Approval/Standard Compliances

• FM-Factory Mutual

 

Standard 4100 (1990).

• NFPA 252

• ANSI/ASTM A526

• ULC-S104

• ASTM A229

• UL-10(b)

• ASTM A480

• NFPA 80

• ASTM A525

• ASTM E152

 

 

 

 

Rolling fire doors up to 162 sq. ft and

C

 

S

 

13'6" in width or 12' in height will bear

*

AS IFI

 

 

L

 

ED

the 4-hour, 3-hour, 1 ⁄2-hour, or ⁄4 hour U.L.

 

 

 

 

 

 

 

 

1

3

R

label as required. Rolling fire doors over 162 sq. ft., and up to 38'1" in width or 28' height, with a maximum area of 576 sq. ft., will receive an oversized fire door label. Factory Mutual (FM)

Listing is available on 3-hour fire doors.

Face-of-Wall Mounting

 

 

 

 

 

 

 

Face-of-Wall Mounting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual Push-Up*, Model FDGF1

 

 

 

 

 

 

 

 

 

Chain Hoist*, Model FDGF2

 

 

 

 

Common Guide Mounting Details

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7"

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Opening

 

 

 

 

 

 

Opening

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Width

 

 

 

 

 

 

Width

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31/2"

 

 

 

 

 

 

31/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Std.

 

 

 

 

 

 

 

B

 

 

 

 

A

 

 

 

 

 

Std.

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

1/4"

 

3"

 

 

1/4"

 

3"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Opening

 

8"

 

 

 

8"

 

 

 

 

 

 

 

 

 

 

Opening

 

 

11"

 

A

 

8"

 

 

Steel-Face-of-wall

Masonry Face-of-wall

 

 

 

 

 

 

 

 

 

Height

 

 

 

Opening Width

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Opening Width

 

 

 

 

mounting

 

 

 

 

 

 

mounting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Consult factory for 34 hr., 112 hr., 3 hr. and 4 hr. mounting details.

*Left-hand operation shown, right-hand is standard

Standard Clearance Area; X = 1612" Y = 15" W = 2012"

Note: Headroom “W” includes a 2" vertical return on the top of the hood where applicable and a 2" standard bracket set up.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

®

 

 

®

 

 

 

 

 

 

 

 

 

 

 

 

Typical Fire Labels applied to AKBAR 89, AKBAR,

and ATLER products.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASSIFIE

ROLLING FIRE

 

 

 

 

 

ASSIFIE

OVERSIZE ROLLING

 

EXCEPT FOR SIZE ANDTEMPERATURE RISE,THIS

 

 

UNDERWRITERS' LABORATORIES OF CANADA

®

 

 

 

 

®

DOOR HAS BEEN MANUFACTURED IN

 

 

 

LISTED

HOMOLOGUE

CL

D

DOOR NO.

 

 

 

 

 

 

 

CL

D

FIRE DOOR NO.

 

COMPLIANCE WITH UL LISTING FILE R107 AND

 

 

ULC

FIRE DOOR DUREE: 3 HR. PORTE COUPE-FEU

C

U® L US

 

 

 

 

 

 

 

 

 

C

U® L US

 

 

 

 

 

CLASS ANDTYPE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOTHE REQUIREMENT FOR DOORS OFTHIS

 

 

RATING

 

 

 

 

 

 

 

SERIAL NUMBER:

 

 

 

 

 

 

 

 

 

SERIAL NUMBER:

 

 

 

 

 

NO.

 

FIRE RATING:

 

 

HRS

 

 

 

FIRE RATING:

 

 

HRS

 

 

 

 

 

ROLLING DOOR DIVISION 14512 LINCOLN WAY E. DALTON, OH 44618

028-0110-04

ROLLING DOOR DIVISION 14512 LINCOLN WAY E. DALTON, OH 44618

028-0109-04

 

 

 

INDUSTRIES CORPORATION LIMITED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAMBRIDGE

ONTARIO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The American Rolling Door Institute supports periodic inspection of Fire Door assemblies as stated in the National Fire Protection Association Standard 80.