Wavetek LP25A, LP10A User Manual

®
TM
iii
WARRANTY
The LP10A and LP25A Logic Probes are warranted against any defects of material or workmanship within a peri od of one (1) year following the date of pur cha s e of the Logic Probe by the original purchaser or original user. Any Logic Probe claimed to be defective during the warranty period should be returned with proof of purchase to an authorized Wavetek Meterman Service Center or to the local Wavetek Meterman dealer or distri bu tor wh er e your Lo gi c Prob e w as purc has ed. See maintenance section for details. Any implied warranties arising out of the sale of a Wavetek Meterman Logic Probe, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to the above stated one (1) year period. Wavetek Meterman shall not be liable for loss of use of the Logic Probe or other incidental or consequential damages, expenses, or economical loss or for any claim or claims for such damage, expenses or economical loss. Some states do not allow limitations on how long implied warranties last or the exclusion or limitation of incidental or consequential damages,
iv
so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
CERTIFICATIONS AND PRECAUTIONS
This instrument is EMC/EMI certified. All inputs are protected against continuous overload conditions up to the limits of each function’s stated input protection (see specifications). Never exceed these limits or the ratings marked on the instrument itself. Always inspect your Logic Probe, test leads and accessories for signs of damage or abnormality before every use. If an abnormal condition exists (broken or damaged test leads, cracked case, display not reading, etc.), do not use. Never ground yourself when taking measurements. Do not touch exposed metal pipes, outlets, fixtures, etc., which might be at ground potential. Keep your body isolated from ground and never touch exposed wiring, connections, test probe tips, or any live circuit conductors. Do not operate instrument in an explosive atmosphere
v
(flammable gases, fumes, vapor, dust.) Do not use this or any piece of test equipment without proper training.
CAUTION: To avoid damaging the instrument, do not use it in a place where ambient temperature exceeds 40°C.
CAUTION: To avoid damaging the instrument, do not input more than 40 VAC or VDC.
CONTENTS Page CONTENTS Page
Warranty ii Certifications and Precautions iii Preparation for use 1 Introduction 1
Control descriptions 3 Operation 3 Maintenance and Repair 4 Specifications 7
1
PREPARATION FOR USE – UNPACKING
Your shipping carton should include the Logic Probe with 0.5 meter long cable with a mini-alligator clip for the ground connection and a mini-grabber for the Vcc connection and this manual. If any of the items ar e dam ag ed or missing, immediately return the complete package to the place of purchase for an exchange.
INTRODUCTION
The LP10A and LP25A Logic Probes are logic troubleshooting instruments that give
visual (LED’s) and audio indications (LP25A only) of logic levels and pulses. They will also capture positive or negative events as short as 30 nanoseconds. The probe is powered by the circuit under test.
2
TTL
HI
LO
TTL
CMOS
MEM
PULSE
LP25A
HI
LO
CMOS
MEM
PULSE
LP10A
LP25A
LP10A
3
CONTROL DESCRIPTIONS
TTL/CMOS – set for logic family of the circuit under test. PULSE/MEM
PULSE – normal operation mode for pulse or level detection. MEM – pulse capture or memory.
OPERATION Setup: Connect the black alligator clip to ground or common of the circuit under
test. Connect the red mini-hook clip to Vcc of the circuit under test. Select TTL or CMOS with the TTL/CMOS switch depending upon the type of logic
being tested. TTL level is nominal 0 to 5 VDC and CMOS levels are 0 to 5 – 15 VDC. The PULSE/MEM switch should be in PULSE for Pulse or Logic level testing.
4
Using the Logic Probe
Touch the LP10A or LP25A probe tip to the circuit point under test. The probes
LED’s indicate the logic level or signals present when the circuit
node is probed.
The LED’s response is noted on page 11.
MAINTENANCE
If there appears to be a malfunction during the operation of the Logic Probe, the following steps should be performed in order to isolate the cause of the problem:
Review the operating instructions for possible mistakes in operating procedure. Inspect and test the Test Cables for a broken or intermittent connection. Any
repair of the Logic Probe shoul d be pe rfo rm ed only by a Factory Authorize d Servi ce Center or by other qualified instrument service personnel. The probe case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow the Logic Probe to dry completely before using. Do not use aromatic hydrocarbons or chlorinated solvents for cleaning.
5
REPAIR
Read the warranty located at the front of this manual before requesting warranty or non-warranty repairs. For warranty repairs, any probe claimed to be defective can be returned to any Wavetek Meterman authorized distributor or to a Wavetek Meterman Service Center for an over-the-counter exchange for the same or like product. Non-warranty repairs should be sent to a Wavetek Meterman Service Center. Please call Wavetek Meterman or enquire at your point of purchase for the nearest location and current repair rates. All probes returned for warranty or non­warranty repair or for calibration should be accompanied by the following
information or items: company name, customer’s name, address, telephone number, proof of purchase (warranty repairs), a brief description of the problem or the service requested, and the appropriate service charge (for non-warranty repairs). Please include the test leads with the meter. Service charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Wavetek Meterman or to the specific service
6
center. For minimum turn-around time on out-of-warranty repairs please phone in advance for service charge rates. The probe should be shipped with transportation charges prepaid to one of the following addresses or to a service center:
in U.S.A. in Canada in Europe
Wavetek Meterman Wavetek Meterman Wavetek Meterman 1420 75th Street SW 400 Britannia Rd. E.Unit #1 52 Hurricane Way Everett, WA 98203 Mississauga, ON L4Z 1X9 Norwich, NR6 6JB, U.K. Tel: 1-877-596-2680 Tel: (905) 890-7600 Tel: int + 44-1603-404824 Fax: 425-446-6390 Fax: (905) 890-6866 Fax: int + 44-1603-482409
7
SPECIFICATIONS
Input signal Levels LED’s BEEPER(LP25A) Logic “1” TTL: > 2.3 V ± 0.2 VDC HI (Red) ON Fixed Tone
CMOS: >70 % Vcc ± 10% HI (Red) ON
Logic “0” TTL: < 0.8 V ± 0.2 VDC LO (Green) ON Fixed Tone
CMOS: <30 % Vcc ± 10% LO (Green) ON Bad Logic Level or Open circuit none No Tone Square Wave < 200 Hz HI and LO blinking Variable Tone
at frequency rate at frequency rate
Square Wave > 200 Hz HI and LO may or Variable Tone
may not be ON at frequency rate
8
Input signal Levels LED’s BEEPER(LP25A)
Narrow Hi Pulse LO (Green) blinking Variable Tone Low with POS pulse intensity depends on at frequency rate
pulse duty cycle
Narrow Lo Pulse HI (Red) blinking Variable Tone High with NEG pulse i nte nsit y depen ds on at frequency rat e
pulse duty cycle
PULSE/ PULSE uses the pulse detection modes listed above. MEMory MEM allows the probe to capture a positive or negative pulse. The
YELLOW LED will come ON and stay ON until switch is reset to PULSE. See page 10 for specifications.
9
Electrical Specifications:
LP10A LP25A
Power Supply 5 - 15 VDC 5 - 15 VDC Power Supply Current @ 5V 30 mA 40 mA @ 15 V 80 mA 90 mA Power Supply Protection 20 VAC/ VDC 20 VAC/VDC Maximum Input voltage 40 VAC/VDC 40 VAC/VDC (15 seconds)
Size 210(8.2) x 18(0.7) x 18(0.7) mm (in.) Weight 38.1(1.3) 42.6(1.5) gm(oz)
TTL/CMOS selectable yes yes Maximum Input Signal Frequency 20 MHz 20 MHz
10
Minimum Detectable Pulse Width
Frequency 1 kHz 1 to 20 kHz 20 kHz to 20 MHz Minimum Pulse width 100 ns 50 ns 30ns Pulse amplitude + 3 V
Input Impedance 1 M 1 M Pulse Indicator Flash Time 500 mS 500 mS Audible tone at pulse rate no yes
Operating Temperature 0 °C to 50 °C at 80 % R.H. Storage Temperature -20 °C to 65 °C at 75 % R.H.
11
Safety: This instrument is intended for use below the Low Voltage Directive, thus is considered exempt from EN61010-1:1993. EMC: This product complies with requirements of the following European Community Directives: 89/336/EEC (Electromagnetic
Compatibility) and 73/23/EEC (Low Voltage) as amended by 93/68/EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic inter fe ren ce.
®
TM
Manual Revision Date 07/00 Manual Part Number 1566429
Information contained in this manual is proprietary to Wavetek Meterman and is provided solely for instrument operation and maintenance. The information in this document may not be duplicated in any manner without the prior approval in writing from Wavetek Meterman. Specifications subject to change.
Wavetek is a trademark of Wavetek Wandel Goltermann
© Wavetek Meterman, 2000
U.S. Service Center Wavetek Meterman 1420 75th Street SW Everett, WA 98203 Tel: (877) 956-2680 Fax: 425-446-6390
Canadian Service Center Wavetek Meterman 400 Britannia Rd. E.Unit #1 Mississauga, ON L4Z 1X9 Tel: (905) 890-7600 Fax: (905) 890-6866
European Distribution Center Wavetek Meterman 52 Hurricane Way Norwich, NR6 6JB, England Tel: (44) 1603-404-824 Fax: (44) 1603-482-409