11. Correction of Malfunctions
Problem Cause Remedy
A. Not enough
material is
coming out
•
The material limiter is set to the
upper position
•
Container empty
•
Trigger is not pressed very often.
•
Container not inserted properly
•
Remains of material around the
container valve
•
Container valve blocked
•
Material too thick
➞ Push the limiter down
➞ Rell container
➞ Press the trigger more
frequently/for longer periods
➞ Insert properly
➞ Clean (see g. 13, a)
➞ Clean (see g. 16 and 17)
➞ Dilute according to
manufacturer's instructions
B. Too much
material is
coming out
•
Material limiter is set to the lower
position
•
Trigger is pressed too frequently.
➞ Push the limiter up
➞ Press trigger less frequently/
for shorter periods
C. No material
comes out
at all
•
Tube loose in container or
blocked
•
Not enough material in the
container
➞ Secure tube or clean (see g.
15)
➞ Rell container
D. Application
of material
does not
cover surface
(stripy)
•
Not enough material on the
application pad
•
Application pad and/or groove
brush damaged
➞ See solutions suggested in
section A
➞ Replace
E. Renuvo leaks• Container not inserted properly
•
Application pad not mounted
correctly
•
Remains of material around the
container valve
➞ Insert properly
➞ Mount application pad
securely
➞ Clean (see g. 13, a)