V-ZUG MWCXSL60 Installation Guide

Page 1
Installation instructions
Microwave Type of construction 60-450
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order specified.

Validity

These installation instructions apply to the model: 939

General notes

If fitting in flammable material, the guidelines and standards for low voltage installations and for the fire protection must be strictly observed.
➤ Open appliance door. The identification plate is located at the front on the bottom left-hand
side (see illustration).
J939.113-4
26.6.12 WIMA

Electrical connections

Electrical connections must made by trained electricians in accordance with the guidelines and standards for low voltage installations and the specifications of the local electricity supply companies. A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should always be checked.
➤ Refer to the identification plate for specifications for the required mains voltage, current type and fuses.
➤ Application height of the appliance: up to max. 2000 m above sea level
➤ The appliance is equipped with a mains cable that should be connected to a distribution box by the customer. For pyrometric reasons
the connection cable is not to be exchanged.
PE/ green/yellow
230 V~
16 A
N blue
L1 brown
1
Page 2
Installation instructions
Microwave Type of construction 60-450

Installation

This appliance is only intended for the installation in a niche.
Minimum installation height: Keep 850 mm distance from the floor to the bottom edge of the microwave!

Installing

596
J939.113-4
26.6.12 WIMA
Detail X
X
545
20
~85˚
454
1. Screw the mounting rail to the floor with the 2 supplied screws A.
2. Place appliance in front of the niche and insert the mains plug.
3. Carefully slide appliance into the niche until it is flush with the front of the cabinets, ensuring that the mains cable is not pinched.
4. Open the appliance door and from the front secure the appliance at the sides with the 2 supplied screws S.
~45
350
S
540
(567)
450
min. 550
560–568
A
600
=
=
374
378
50
A, S=
B=
Niche
Appliance

Installing with a second appliance in the same niche

If a second appliance is installed in the same niche (above or below the appliance), you should use bracket set 60 W to support the upper appliance.
It is not possible to install the appliance above an extractor oven because of the extraction pipes that lead upwards.
Below a second appliance Above a second appliance
560–568
450
50
456
1. Screw the mounting rail to the floor with the 2 supplied screws A or to the bracket with screws B.
2. Place appliance in front of the niche and insert the mains plug.
3. Carefully slide appliance into the niche until it is flush with the front of the cabinets, ensuring that the mains cable is not pinched.
4. Open the appliance door and from the front secure the appliance at the sides with the 2 supplied screws S.
W
min. 550
A
2
B
50
560–568
min. 550
W
Loading...