Vulcan Hart VSX24G, VSX24G5 General Manual

Item # __________________________
C.S.I. Section 11420
REGENERATED STEAM SERIES CONVECTION STEAMER ON CABINET BASE
VSCX2-6 6-pan capacity
VSCX2-10 10-pan capacity
STANDARD FEATURES
Two stainless steel cooking compartments with coved interior corners. Each compartment accepts:
- 1" deep pans (6 - VSCX2-6)(10 - VSCX2-10)
1
-2
2" deep pans (3 - VSCX2-6)(5 - VSCX2-10)
- 4" deep pans (2 - VSCX2-6)(3 - VSCX2-10)
1
1
4" drain in each compartment.
Heavy duty stainless steel "slammable" doors can be opened and closed at anytime during the cooking cycle. Steam shuts off when door(s) are opened.
Compartment controls include 60 minute dial timer with buzzer, green "ready" and red "cooking" indicator lights.
Convection steamer mounted on 28" high base cabinet with stainless steel front full height doors, slip-off stainless steel side and aluminized steel rear panel with welded 6" stainless steel legs rear with flange foot and front with bullet.
Direct steam supply at 15 to 50 PSI with a flow of 200 lbs. steam/hr. Includes high pressure limit control and 15 psi safety relief valve, low water control with automatic fill and blowdown.
One year limited parts and labor warranty.
Vulcan-Hart Co.
ISO9001
A2780
MODELS: VSCX2 SERIES
Regenerated Steam Convection Steamer on Cabinet Base
SPECIFICATIONS:
Regenerated steam generator convection steamer, Vulcan-Hart Model No. VSCX2. Two stainless steel cooking compartments with coved interior corners. Each compartment accepts six 1" deep, three 2 in each compartment. Heavy duty stainless steel "slammable" doors can be opened and closed at anytime during the cooking cycle. Steam shuts off when door(s) are opened. Compartment controls include 60 minute dial timer with buzzer, green "ready" and red "cooking" indicator lights. Convection steamer mounted on 28" high base cabinet with stainless steel front full height doors, slip-off stainless steel side and aluminized steel rear panel with welded 6" stainless steel legs rear with flange foot and front with bullet. Direct steam supply at 15 to 50 PSI with a flow of 200 lbs. steam/hr.
Exterior dimensions: VSCX2-6: 24"w x 33"d x 60 VSCX2-10: 24"w x 33"d x 68
NSF listed. U L listed. Meets ASME code.
1
2" deep or two 4" deep 12" x 20" pans. 11⁄4" drain
1
2"h.
1
2"h.
OPTIONS
Stainless steel cabinet back.
Correction facility package:
a. Security type tamper resistant fasteners with tack welds. b. Control cover with hasp (lock by others). c. Cabinet door with hasp (lock by others).
Step down transformer for control circuit if higher than
120 volts.
Second year extended limited parts and labor warranty.
ACCESSORIES:
Water filter system.
Wire rack.
Pressure reducing valve.
Ball float trap.
F-32482 (8-04)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
REGENERATED STEAM SERIES CONVECTION STEAMER ON CABINET BASE
DIRECT STEAM DATA:
Steam supply to the regenerated steamer must:
1. Maintain a steady 15 to 50 psi flow under operating conditions.
2. Have a minimum flow rate of 125 lbs. per hour, dry steam.
3. Be adequately trapped to provide dry steam. (See ball float trap.)
4. Provide a service shut-off valve.
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable for steam generation. Your water supply must be within these general guidelines:
SUPPLY PRESSURE 20 - 80 psig HARDNESS* less than 3 grains SILICA less than 13 ppm CHLORIDE less than 30 ppm pH RANGE 7-8
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. Water supplies vary from state to state and from locations within a state. Therefore it is necessary that the local water treatment specialist be consulted before the installation of any steam generating equipment.
SERVICE CONNECTIONS:
Steam Supply: 3⁄4" NPT for 15 - 50 psi direct steam.
Electric Connection for Controls: 120/60/1, 300 watt maxi-
mum power supply with grounding wire required. (For other than 120 volt supply, consult factory for location of this conneciton.)
Drain: Condenser box, compartment and boiler, 2" NPT. (Provide an open air gap type drain within 12" of condenser box. Do not connect solidly to any drain connection.)
Cold Water Connection: 3⁄8" NPT for boiler feed. Inlet water pressure between 20 and 80 psi.
Cold Water Connection:3⁄8" NPT for condensate box. Inlet
water pressure between 20 and 80 psi.
Water: For swing faucet, (single) (dual) temperature 1⁄4" IPS tailpiece.
Steam Take-Off Connection:3⁄4" NPT.
NOTE:
• Dimensions which locate the above connections have a tolerance of
+ or -3" (+ or -77 mm).
• Installation of backflow preventers, vacuum breakers and other
specific code requirements is the responsibility of the owner and installer. It is the responsibility of the owner and installer to comply with local codes.
• This appliance is manufactured for commercial installation only and
is not intended for home use.
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and specifications without notice.
F-32482 (8-04)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
Printed On Recycled Paper
Loading...