Vulcan-Hart 2T2036E Specifications

Page 1
Item # __________________________
MODEL 2T2036E
C.S.I. Section 11420
TWO 24 QUART 2/3 JACKETED TILTING KETTLES ON ELECTRIC BOILER BASE
STANDARD FEATURES
2
Two
Steam jacketed kettles mounted on 28" high base cabinet
Fully welded hemispheric bottom kettle with type 304 stain-
Steam control valve on right trunnion leg.
12" single temperature deck mounted faucet.
CSD-1 code compliant boiler.
Electric 24 KW steam boiler.
Requires a 208 or 240 volt, 60 Hz, 3 phase power supply
Water filter system, SPS620V. Includes second year extended
One year limited parts and labor warranty.
/3 jacketed tilting steam kettles, 24 quart capacity
each.
with front full height doors, slip-off stainless steel side and aluminized rear panel with 6" adjustable legs with flanged feet for anchoring.
less steel jacket and type 316 stainless steel liner. Jacket tested to 50 psi (3.4 kg/cm
2
).
and a separate 120 volt, 60 Hz, 1 phase control circuit, 3 amp.
limited water associated parts and labor warranty.
Vulcan-Hart Co.
ISO9001
A2780
MODEL: 2T2036E
Two 24 Quart
SPECIFICATIONS:
Two 24 quart 2/3 jacketed tilting steam kettles mounted on a 36" wide electric boiler base, Vulcan-Hart Model No. 2T2036E. Steam jacketed kettles mounted on 28" high base cabinet with front full height doors, slip-off stainless steel side and aluminized rear panel with 6" adjustable legs with flanged feet for anchoring. Fully welded hemispheric bottom kettle with type 304 stainless steel jacket and type 316 stainless steel liner. Jacket tested to 50 psi (3.4 kg/cm
2
). Steam control valve on right trunnion leg. 12" single temperature deck mounted faucet. Requires a 208 or 240 volt, 60 hz, 3 phase power supply and a separate 120 volt, 60 Hz, 1 phase control circuit, 3 amp.
Exterior dimensions: Cabinet: 36"w x 33"d x 28"h on 6" adjustable legs. Overall height to the lip of the kettles - 46", to the top of the handle - 54".
U L listed. Classified by U L to NSF Std. #4. Meets ASME Code.
OPTIONS
Correction package.
- Cabinet door with hasp (lock by others).
- Security type tamper resistant fasteners.
- Front flanged feet.
Stainless steel finishing back.
Tilting kettle strainer (one) (two).
12" dual temperature faucet.
Single phase on 24 KW boiler.
Stepdown transformer (eliminates 120 volt connection).
36 KW boiler, 3 phase only.
42/48 KW boiler, 3 phase only.
480 volt, 60 Hz, 3 phase, includes stepdown transformer.
Mount and interconnect kettle with boiler base at factory.
Includes steam supply piping. Shipped on one skid.
Second year extended limited parts and labor warranty.
ACCESSORIES
Stainless steel back panel.
Lift-off cover (one) (two).
Contour measuring strip.
Single perforated stainless steel basket (one) (two).
2
/
3
Jacketed Tilting Kettles On Electric Boiler Base
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
F-32379 (10-03)
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
Page 2
MODEL 2T2036E
TWO 24 QUART 2/3 JACKETED TILTING KETTLES ON ELECTRIC BOILER BASE
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable for steam generation. Your water supply must be within these general guidelines:
SUPPLY PRESSURE 20 - 60 psig HARDNESS* less than 3 grains SILICA less than 13 ppm TOTAL CHLORIDE less than 4.0 ppm pH RANGE 7-8 UN-DISSOLVED SOLIDS less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of chloridation and dissolved gases. Water supplies vary from state to state and from locations within a state. Therefore it is necessary that the local water treatment specialist be consulted before the installation of any steam generating equipment.
AMPS PER LINE
3 PHASE-4 WIRE
KW
INPUT 208V 240V 208V 240V 480V 240/415V
24 116 100 67 58 29 34 36 NA NA 100 87 44 50 42 NA NA 117 NA NA NA 48 NA NA NA 116 58 67
1 PHASE 3 PHASE 220/380V
SERVICE CONNECTIONS: A Electrical Connection for Boiler Heat: Junction box see capacity
chart.
B Electrical Connection for Controls: 120/60/1. 300 watt maximum,
power supply with grounding wire required.
C Drain: Condensate box, compartment and boiler, 11/4" NPT. (Provide
an open air type drain within 12" of condensate box and for best results at a distance so that steam vapors will not enter the steamer from underneath the control area. Do not connect solidly to any drain connection.)
D Cold Water Connections (2):
D1 Treated Cold Water Connection:
water pressure between 20 and 80 psi.
D2 Untreated Cold Water Connection: 1/4" NPT for condensate
box. Inlet water pressure between 20 and 80 psi.
E Water: For swing faucet, (single) (dual) temperature,
tubing.
NOTE:
• Dimensions which locate the above connections have a tolerance of + or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other specific code requirements is the responsibility of the owner and installer. It is the responsibility of the owner and installer to comply with local codes.
• Plastic drains are not recommended due to inherent limited temperatures of the plastic. Boiler purge temperatures may exceed 180°F. The installer may be required to provide means to reduce boiler purge water temperature to be that of the condensate temperature of 140°F or less.
• This appliance is manufactured for commercial installation only and is not intended for home use.
1
/4" NPT for boiler feed. Inlet
1
/4"
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and specifications without notice.
F-32379 (10-03)
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
EQUIPMENT CLEARANCE: Rear: 2" Right: 0" Left: 0"
BRIMFUL CAPACITIES (in 4 oz. servings):
24 quarts / 6 gallons / 22.5 liters - 192 servings.
Printed On Recycled Paper
Loading...