V-tech DT601/FP, DT601F/FP User Manual

DT601/FP DT601F/FP
English
User Manual
2-Wire Video Outdoor Station
DT-ENG-601(F)FP-V1 141023
Side View
Fingerprint window
Rainy Cover
DT601/FP
93 mm
182 mm
30 mm
DT601F/FP
220 mm
120 mm
Camera Lens
Speaker
Call Button
Microphone
Night Light
Screws for panel mounting
Camera Lens
Speaker
LED 2
Call Button
Microphone
Night Light LED 1
KEY 2KEY 1
LED 2
LED 1
KEY 2KEY 1
Fingerprint window
1.Parts and Functions
2.Terminal Descriptions
1 2 3
Lock Control Jumper
BUS
PL
S+
S-
Main Connect Port
-1-
3.Door Station Mounting
1 2
43
Drill holes in the wall to match the size of screws and attach the rainy cover to the wall.
Attach the panel to the rainy cover Use the screwdriver and the screw
to fix the panel
Connect the cable correctly
3.1 DT601/FP Mounting
-2-
Lock Control Jumper:
To select the lock type.
Main Connect Port:
To connect the bus line and the electronic locks.
•BUS: Connect to the bus line, no polarity.
PL: External lock power input, connect to the power positive(power +).
S+: Lock power(+) output.
S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door station to power the locks, if using the external power supply for the locks, the S- will not be connected).
3.2 DT601F/FP Mounting
1 2
43
Drill a hole in the wall to match the size of the mounting box and attach to the wall.
Attach the panel to the mounting box and use screws supplied to fix the panel
Connect the cable correctly
4. System Wiring and Electric Lock Connection
4.1 Basic Connection
BUS(IM) BUS(DS)
PC6
AC~
-
+
L1 L2 PL S+ S-
Doorbell Button
Switch
1 2 3
ON
DIPS
-3-
-4-
4.2 Electric Lock Connection
4.2.1 Door Lock Controlled with Internal Power
Note:
1. Electronic lock of Power-on-to-unlock type should be used.
2. The door lock is limited to 12V, and holding current must be less than 250mA.
3. The door lock control is not timed from Exit Button(EB).
4. The
Unlock Mode
Parameter of
Monitor must be set to 0 (by default).
EB
*
LOCK
BUS PL S
+
S-
Jumper position in 2-3
1 2 3
LOCK
Take off the Jumper
POWER SUPPLY
BUS PL S
+
S-
4.2.2 Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according to the lock.
2. The inside relay contact is restricted to AC or DC 24V/1A.
3. The jumper must be taken off before connecting.
4. Setup the
Unlock Mode
of Monitor for
different lock types.
Power-on-to-unlock type:Unlock Mode=0 (by default)
Power-off-to-unlock type:Unlock Mode=1
4.3 Unlock parameter setting(set on monitor)
-5-
4.4 Multi Door Stations Connection
1# Camera2# Camera3# Camera4# Camera
L1 L2 PL S+ S-L1 L2 PL S+ S-
L1 L2 PL S+ S-
L1 L2 PL S+ S-
(Device Address:3) (Device Address:2) (Device Address:1) (Device Address:0)
100~240VAC
DBC4A
A B C D
OFF
ON
Impedance
switch
BUS(IM) BUS(DS)
PC6
AC~
Note:
1.must connect DT601(F)/FP correctly before setting.
2.the parameter will be saved in DT601(F)/FP automatically,so you need only set on one monitor.
3.Here we take DT47M(the monitor) for example, please refer to the corresponding user manual.
1.Touch icon on main menu page.
2.Touch
UNLOCK
button and hold for 2s.
3.A digital keypad will be shown.
About
Local Address 00.00
Video Standard
AUTO
System Verson 00.01.00
Display Driver 1.0
Front 1.0
UI 1.0
INSTALLER SETUP
123
_