English
User Manual
2-Wire Video Outdoor Station
DT601FE/KP
1
4 5 6
98
0 #
7
2 3
*
DT-ENG-601FE/KP-V1 151019

Contents
1.Parts and Functions............................................................................................. 1
2.Terminal Descriptions .......................................................................................... 1
3.Door Station Mounting ......................................................................................... 2
4.System Wiring and Connections ......................................................................... 3
5.Fisheye Camera Function ................................................................................... 7
6. Functions Setting Up .......................................................................................... 7
7.Unlock Operations ............................................................................................... 15
8. Precaustions ....................................................................................................... 15
9.Specications ...................................................................................................... 15
10.Cables Requirements ........................................................................................ 16

-1-
1.Parts and Functions
DT601FE/KP Side View
Mounting box
220 mm
120 mm
1
4 5 6
98
0 #
7
2 3
*
Camera Lens
Speaker
Touch Sensitive
Digital Keypad
Nameplate
Call Button
Microphone
Night Light
Screws for panel
mounting
1
4 5 6
98
0 #
7
2 3
*
2.Terminal Descriptions
1 2 3
Lock Control Jumper
BUS
PL
S+
S-
Main Connect Port
•
Lock Control Jumper:
To select the lock type.
•
Main Connect Port:
To connect the bus line and the electronic locks.
•BUS: Connect to the bus line, no polarity.
• PL: External lock power input, connect to the power positive(power +).
• S+: Lock power(+) output.
• S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door
station to power the locks, if using the external power supply for the locks, the S- will not be
connected).

-2-
3.Door Station Mounting
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
1 2
43
Drill a hole in the wall to match the size of the
mounting box and attach to the wall.
Attach the panel to the mounting box and
use screws supplied to fix the panel
Connect the cable correctly
Placing Name Label
Use a screwdriver to unscrew the screw,
and cock the host , then Placing Name
Label.
DT601FE/KP Mounting

-3-
Basic Connection
4.System Wiring and Connections
BUS(IM) BUS(DS)
PC6
AC~
-
+
L1 L2 PL S+ S-
Doorbell Button
1 2 3
ON
DIPS
Electric Lock Connection
EB
*
LOCK
BUS PL S
+
S-
Jumper position in 2-3
1 2 3
Door Lock Controlled with Internal Power
Note:
1. Electronic lock of Power-on-to-unlock type
should be used.
2. The door lock is limited to 12V, and holding
current must be less than 250mA.
3. The door lock control is not timed from Exit
Button(EB).
4. The
Unlock Mode
Parameter of Monitor
must be set to 0 (by default).