Read this manual carefully before using the product, and keep it well for future use.
Introduction
BUS
PL
S1+ S2+ S-
The door station is designed with high resolution color CCD camera, it provides wide angle of 1050 for DT 2-wire intercom system. The high white LED
for night view makes the door station working efciently at night.
The front panel is made of medical stainless steel with a thickness of 2.5 mm
for better protection against vandalism and cauterization. The call button is
made of durable zinc alloy with white backlight for illumination. The name label
with orange backlight is covered by a fully secured and ameproof glass plate.
Parts and Function
Terminal Description
ON
T/R+ T/R-
1 2 3
Doorstation Code DIP
1 2
Lock Control Jumper
Mounting box
1
Plastic bracket
2
Front panel
3
Camera lens
4
Speaker
5
Name label
6
Microphone
7
Call button
8
Main Connect Port
Spanner
9
Fixed axis B
10
Camera adjustment
11
Connection port
12
Fixed axis A
13
Name plate hole
14
Signal adjustment
15
-3-
Lock Control Jumper:
Door Station Code DIP:
T/R+,T/R-:
USB-RS485 communication terminal.
Main Connect Port:
To select the lock type.
Total 4 door stations can be supported.
To connect the bus line and the electronic locks.
BUS: Connect to the bus line, non-polarity.
PL: External lock power input, connect to the power positive(power +).
S1+, S2+: Lock power(+) output, to connect 2 locks.
S-: Lock power(-) output.
Door Station Mounting
1234
OPEN
CLOSE
90°
Steps:
1. Drill a hole in appropriate size, then attach the mounting box to the hole.
2. Adjust the camera angle, and connect the cable correctly.
3. Attach the front panel to the mounting box.
4. Use the special spanner to move 900 to x the front panel.
Adjusting Camera Angle
-4-
Use a screwdriver to loosen
the screw and then adjust the
angle of the camera ,then x
the screw.
Placing Name Label
123
Open
90°
Close
Steps:
1. Use the special spanner to move 900 to loosen the screw.
[0010]#:Remove all remote control
[0011]#:Add remote control
[8000]#:Set as master unit 0
[8001]#:Set as slaver unit 1
[8002]#:Set as slaver unit 2
[8003]#:Set as slaver unit 3
[8004]#:Set as guard unit
[8005]#:Set as not guard unit
[8006]#:Panel on as slaver unit called
[8007]#:Panel off as slaver unit called
[8008]#:Date format:MM/DD/YYYY
[8009]#:Date format:DD/MM/YYYY
[8010]#:Set lock mode to 0
[8011]#:Set lock mode to 1
2.the parameter will be saved in door station automatically,so you need only
set on one monitor.
3.the above diagram is t for icon menu series monitors only, to text menu series monitors,please refer to the corresponding user manual.
-9-
DIP Switches Setting
The DIP switch is designed to set the code
for door station and monitor, there are two
states for each DIP switch, please refer to
ON(1)
ON
OFF(0)
ON
=
=
the sketch map.
Door station DIP setting
Total 2 bits can be congured, bit-1 and bit-2 are used to assign ID code for door station.The switches can be modied either before or after installation.
Bit state Descriptions
1
1 2
ON
2
ON
ON
1 2
ON
1 2
Default setting, ID = 0(00), set to the rst Door Station.
ID = 1(10), set to the second Door Station.
ID = 2(01), set to the third Door Station.
ID = 3(11), set to the fourth Door Station.
Indoor monitor DIP setting
There are 6 bits in total. The DIP switches are used to congure the user code
for Monitors.
Bit-6 is an video impedance match switch, which have to be set to ON if match
the impedance, otherwise set to OFF.
Bit-1~Bit-5 are used to set user code, for DT597 door station, the user code
should be set to 0~15.
Please refer to the following settings:
-10-
Bit stateUser code
Bit stateUser codeBit stateUser code
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
code=0
code=1
code=2
code=3
code=4
code=5
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
code=6
code=7
code=8
code=9
code=10
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Specication
Power Supply : DC 24V (supplied by PC6);
Power Consumption: Standby 60mA; Working status 200mA;
Camera: 1/4 ACS 4T image sensor with DSP processor
Lock Power supply: 12Vdc, 300mA(Internal Power);
Working temperature: -10ºC ~ +45ºC
Dimension: 188(H)×110(W)×34(D)mm
code=11
code=12
code=13
code=14
code=15
Precautions
• Please clean the unit with soft cotton cloth, don't use the organic impregnant
or chemical clean agent. If necessary, please use a little pure water or dilute
soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on
access control keypad directly. Excessive moisture may cause problems with
the unit.
• You must use the right adaptor which is supplied by the manufacturer or approved by the manufacturer.
• Pay attention to the high voltage inside the products, please refer service
only to a trained and qualied professional.
-11-
Cables Requirements
The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can
reach.
The farest monitor
monitor
with two or four monitors
monitor
When Monitor quantity < 20
Cable UsageABC
2
2
60 60 30
80 80 40
Twisted cable 2x0.75 mm
Twisted cable 2x1 mm
When Monitor quantity > 20
Cable UsageABC
2
Twisted cable 2x1 mm
Twisted cable 2x1.5 mm
70 30 20
2
70 50 30
AC~
monitor
C
PC6
DBC-4S
B
A
Note:If the monitor has been specied
the distance,refer to the parameter.
-12-
The design and specications can be changed without notice to the user. Right to
interpret and copyright of this manual are preserved.
DT-ENG-597-V1 P120924
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.