V-Tech DT595A User Manual

DT595A USER MANUAL(EN)
2-Wire Video Intercom System
Read this manual carefully before using the product, and keep it well for future use.
Parts and Function
Unit Mounting
The location of outdoor station should keep away from snow,rain,and intensity light.
Accessory contents:
Accessories include a screwdriver T20, one M4X10 screw, two PA4X25 screws,three PA3x25
screws,three PM3x12 screws,and five screw stoppers Φ6X30.
Installation steps:
Installation height for door station usually is 145~160cm.
1. Use screws to fix the back panel and rainy cover to the wall after connect the cable correctly.
2. Attach the front panel to the back panel, then use the screw to fix it.
Wiring and Connection
Basic one-to-one connecon
BUS(Blue&Green); S2+(Red); PL(White); S1+(Yellow); S1-(Black);
please refer to DT-CAM user instructions in details. PL(White): external lock power input, connect to the power positive(power +). S1+(Yellow): lock power(+) output. S1-(Black): lock power(-) output.
The door station is an audio door station without camera,which is designed for DT 2-wire system. The front panel is made of zinc alloy for better protection against vandalism & cauterization, and the call button is also made of zinc alloy with blue backlight for auxiliary illumination, the unlock and talking LED indicator guarantee the door station working efficiently. With the rainy cover, the door station can be strongly protection against water.
Speaker
1
1
Unlock Indicator
2
Talk Indicator
2
3
7
4
5
6
3
4
5
6
7
Front Panel
Call Button
Microphone
Rainy Cover
Terminal Description
Lock Control
Jumper
1 2 3
4P
terminal
SPK adjust
DIP PROG
ON
1 2
3
CALL button
1 2 3
ON
1 2 3
Connection line
BUS(Blue&Green) S2+(Red)
PL(White)
S1+(Yellow) S1-(Black)
-3-
◆ Lock Control Jumper: to select the lock type. Please refer to Electric Lock Connection
◆ DIP switch: to set ID code for door station, total 4 door stations can be supported. Please
refer to DIP Switch Setting.
◆ SPK adjust: to adjust the talk volume.
◆ PROG button: reserve.
◆ CALL button: press to call the user.
◆ 4P terminal: to update software via specified programmer.
◆ Connection line: to connect the bus line and the electronic locks.
BUS(Blue&Green):
connect to the bus line, no polarity.
S2+(Red): the S2+ connect with S1- to activate the relay of ERL to extend a camera of DT-CAM,
please refer to DT-CAM user instructions in details. PL(White): external lock power input, connect to the power positive(power +). S1+(Yellow): lock power(+) output. S1-(Black): lock power(-) output.
Unit Mounting
The location of outdoor station should keep away from snow,rain,and intensity light.
Accessory contents:
Accessories include a screwdriver T20, one M4X10 screw, two PA4X25 screws,three PA3x25
screws,three PM3x12 screws,and five screw stoppers Φ6X30.
Installation steps:
Installation height for door station usually is 145~160cm.
1. Use screws to fix the back panel and rainy cover to the wall after connect the cable correctly.
2. Attach the front panel to the back panel, then use the screw to fix it.
1 2 3
PM3*12
M4*10
Wiring and Connection
Basic one-to-one connecon
AC~
PC6
Bus PL S2+ S1+ S1-
-
+
BUS(Blue&Green); S2+(Red); PL(White); S1+(Yellow); S1-(Black);
Monitor
-4-
Mul Door Staon Connecon
With DBC-4S Wiring Mode
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=3, DIP-6=on
Code=1, DIP-6=on
Code=15, DIP-6=on
Code=13, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
ID=10
ON
1 2 3
A B C D
DBC-4S
1# Camera
ID=00
ON
1 2 3
PC6
AC~
2# Camera3# Camera4# Camera
ON
1 2 3
Bus PL S2+ S1+ S1- Bus PL S2+ S1+ S1- Bus PL S2+ S1+ S1- Bus PL S2+ S1+ S1-
ID=01ID=11
ON
1 2 3
DIP=on,off,off
OFF
ON
Impedance
Switch
BUS(Blue&Green); S2+(Red); PL(White); S1+(Yellow); S1-(Black);
Multi Monitors Connection
Basic IN-OUT wiring mode
ON
1 2 3 4 5 6
Code=0, DIP-6=off
ON
1 2 3 4 5 6
Code=1, DIP-6=off
ON
1 2 3 4 5 6
Code=14, DIP-6=off
Monitors
ON
1 2 3 4 5 6
Code=15, DIP-6=on
-5-
monitor monitor monitor monitor
AC~
PC6
ID=00
ON
1 2 3
With DBC-4S Wiring Mode
ON
1 2 3 4 5 6
Code=15, DIP-6=on
ON
1 2 3 4 5 6
Code=13, DIP-6=on
ON
1 2 3 4 5 6
Code=3, DIP-6=on
ON
1 2 3 4 5 6
Code=1, DIP-6=on
monitor
monitor
monitor
monitor
ON
1 2 3 4 5 6
Code=14, DIP-6=on
ON
1 2 3 4 5 6
Code=12, DIP-6=on
ON
1 2 3 4 5 6
Code=2, DIP-6=on
ON
1 2 3 4 5 6
Code=0, DIP-6=on
monitor
monitor
monitor
monitor
AC~
Impedance
switch
Impedance
switch
OFF ON
DBC-4S
A B C D
DIP=on,off,off
OFF ON
DBC-4S
A B C D
DIP=on,off,off
PC6
ID=00
ON
1 2 3
-6-
With DT-CAM wiring mode
DIP Switch Setting
The DIP switch is designed to set the code for door station and monitor, there are two states for each DIP switch, please refer to the following sketch map.
Door station DIP setting
Indoor monitor DIP setting
Total 3 bits can be configured, bit-1 and bit-2 are used to assign ID code for door station, bit-3 is used to match the video impedance.The switches can be modified either before or after installation.
There are 6 bits in total. The DIP switches are used to configure the user code for Monitors.
Bit-6 is an video impedance match switch, which have to be set to ON if match the impedance,
otherwise set to OFF. Bit-1~Bit-5 are used to set user code, to DT595A door station, the user code should set to 0~15. Please refer to the following settings:
Note: if the video impedance need to match, please set the bit-3 on.
The audio door station DT595A can be extended an additional CCTV camera to be a video door station. For more details about the camera, please refer to DT-CAM user instructions.
DT-CAM
Bus PL S2+ S1+ S1-
DT595A
OUT IN
ERL
AC~
PC6
DS IM
Monitor
Electric Lock Connecon
Door Lock Controlled with Internal Power
1 2 3
Connect one lock
Jumper position in
Bus PL S2+ S1+ S1-
EB
*
2-3
LOCK
Note:
1. Electronic lock of Power-on-to-unlock type should be used.
2. The door lock is limited to 12V, and holding current must be less than 250mA.
3. The door lock control is not timed from Exit Button(EB).
4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).
Door Lock Controlled with Dry Contact
Take off the Jumper
Bus PL S2+ S1+ S1-
POWER SUPPLY
-7-
LOCK
Note:
1. The external power supply must be used according to the lock.
2. The jumper must be taken off before connecting.
3. Setup the Unlock Mode of Monitor for different lock types. * Power-on-to-unlock type:Unlock Mode=0 (by default) * Power-off-to-unlock type:Unlock Mode=1
DIP Switch Setting
The DIP switch is designed to set the code for door station and monitor, there are two states for each DIP switch, please refer to the following sketch map.
ON(1)
ON
=
OFF(0)
ON
=
Door station DIP setting
Total 3 bits can be configured, bit-1 and bit-2 are used to assign ID code for door station, bit-3 is used to match the video impedance.The switches can be modified either before or after installation.
Bit state Description
ON
ID = 0(00), set to the first door station
2 3
1
ON
ID = 1(10), set to the second door station
2 3
1
ON
ID = 2(01), set to the third door station
ID = 3(11), set to the fourth door station
ON
2 3
1
2 3
1
Note: if the video impedance need to match, please set the bit-3 on.
Indoor monitor DIP setting
There are 6 bits in total. The DIP switches are used to configure the user code for Monitors.
Bit-6 is an video impedance match switch, which have to be set to ON if match the impedance,
otherwise set to OFF. Bit-1~Bit-5 are used to set user code, to DT595A door station, the user code should set to 0~15. Please refer to the following settings:
-8-
When Monitor quanty < 20
When Monitor quanty >20
Bit state User code
Cable Requirements
The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach.
Twisted cable 2x0.75 mm
Twisted cable 2x1 mm
Twisted cable 2x1 mm
Twisted cable 2x1.5 mm
Note:If the monitor has been specified the distance,refer to the parameter.
Bit state User code Bit state User code
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
code=0
code=1
code=2
code=3
code=4
code=5
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
code=6
code=7
code=8
code=9
code=10
Specification
• Power Supply:DC 24V
• Power Consumption:Standby 60mA; Working status 200mA
• Lock Power Supply:12Vdc, 300mA(Internal Power)
• Working Temperature:
-10ºC ~ +45ºC
• Wiring: 2 wires,non-polarity
• Dimension:137(H)x49(W)x28(D)mm
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
code=11
code=12
code=13
code=14
code=15
-9-
Precaustions
• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent.
If necessary, please use a little pure water or dilute soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on access control keypad
directly. Excessive moisture may cause problems with the unit.
• You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.
• Pay attention to the high voltage inside the products, please refer service only to a trained and qualified
professional.
Cable Requirements
The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach.
The farest monitor
monitor
with two or four monitors
monitor
When Monitor quanty < 20
Cable Usage A B C
Twisted cable 2x0.75 mm
Twisted cable 2x1 mm
2
60 60 30
2
80 80 40
When Monitor quanty >20
Cable Usage A B C
Twisted cable 2x1 mm
Twisted cable 2x1.5 mm
2
70 30 20
2
70 50 30
AC~
monitor
C
PC6
DBC-4S
B
A
Note:If the monitor has been specified the distance,refer to the parameter.
-10-
The design and specications can be changed without notice to the user. Right to
interpret and copyright of this manual are preserved.
DT-ENG-595A-V1 P120924