VVooxx VVCC--1122 MMaaiinn FFeeaattuurreess
Foot Controller
EasyStart CONTENTS
VC-12 Overview, Connections and Applications:
Preset programs, Storing programs 1-4
Loading Program Data into your Valvetronix Amp 4
VC-12 Preset Program List4
VOX VC-12 EasyStart
VVCC--1122 OOvveerrvviieeww
The VC-12 Foot Controller is a pedal board for controlling VOX BUS- compatible equipment, including
VOX Valvetronix amps and VOX Valvetronix ToneLab Direct Recording/Performance Processor. You can
use your VC-12 to do the following:
• Select programs
• Control the VOX-Wah effect
• Control the speed of the U-VIBE effect
• Control the speed of Modulation effects
• Set the delay time by using the TAP switch
• Turn the Pedal, Modulation, Delay, and Reverb effects on and off individually
• Instantly recall a previously-selected program
• Tune your guitar
• Select from 96 programs from Tonelab
• Store your Valvetronix amps program data (32 Programs x 4 Sets =128 programs)
• Select programs on two Valvetronix amps at one time
• Sounds saved on the VC-12 can be transferred to another Valvetronix amp
CCoonnnneeccttiioonnss
The VC-12 can be connected to VOX-BUS compatible equipment, including:
AD60VT, AD120VT, AD60VTH, AD120VTH, AD60VTX, AD120VTX, ToneLab
1. Turn off all equipment before making any connections.
2. Connect the included 10 Base-T straight cable to the VOX BUS MAIN connector on the rear panel of your VC-
12.
3. Connect the other end of the cable to the FOOT CONTROLLER connector or VOX BUS connector on your
Valvetronix amp or VOX BUS-compatible device.
RREECCAALLLL sswwiittcchh
In Channel Select Mode, this switch recalls the previously selected program. You can use this to quickly switch
between programs in different banks.
TTaapp sswwiittcchh && LLEEDD
This switch is used to set the delay time. The VC-12 measures the time between the last two taps to calculate the
delay time. LED blinks to set the time.
This switch is used to toggle between Channel Select Mode and Effect On/Off mode.
In Channel Select Mode, switches 1-4 are used to select programs. LEDs 1-4 indicate the currently selected
programs.
In Effect On/Off mode, these switches are used to turn the Pedal, Modulation, Delay, and Reverb effects on and off
individually. LEDs 1-4 indicate whether an effects section is on or off.
VVCC--1122 PPrreesseett PPrrooggrraammss
The VC-12 is capable of storing four banks of Valvetronix amp user programs. Valvetronix amps alone
can store 32 programs, whereas the VC-12 offers the user an additional 96 programs for a total of 128
programs (32 x 4 = 128). Programs can be stored from any Valvetronix amp into the VC-12, and loaded
to another amp. As an added bonus, the VC-12 can control two Valvetronix amplifiers at one time. in
The areas assigned to Switches #1, #2, #3 contain 32 factory-preset programs in each memory bank.
Switch #4 is empty. It’s a really good idea to first load your 32 Valvetronix amp programs to Switch #4
so they will be safely stored in the VC-12’s memory.
2
VOX VC-12 EasyStart
Note: When you reload the VC-12’s factory preset programs into the Valvetronix amp, any new custom programs
will be overwritten and lost. If you have stored your own programs, we again strongly recommend that you first save
these programs into the VC-12 Switch #4 area. Then load the VC-12’s factory preset programs into the Valvetronix
amp.
Factory preset program Banks “1 through 4” contain the same programs as Banks “1. through 4.” (as indicated in
the display) - For example, you can use Banks “1 through 4” without change, and edit Banks “1. through 4.”
Store your Valvetronix Programs in the VC-12’s four memories:
1. Turn off the Valvetronix amp and make sure it’s connected to the VC-12’s VOX BUS MAIN
connector.
Note: Don’t connect anything to the VC-12’s VOX BUS SUB connector.
2. On the Valvetronix amp, while holding down the DELAY [TAP] button and the REVERB [TYPE]
button, turn on the amp.
The VC-12’s BANK display shows [bU] BackUp.
3. Press the VC-12’s BANK UP switch.
The VC-12’s BANK display shows [rC] Receive.
Switch LED’s (1-4) that contain no program data are off, while those that do contain program data are on.
4. Use switches 1 through 4 to select the memory (1, 2, 3, 4) into which you want to store the
program data (for example switch #4). The selection method you need to use depends on
whether the switch’s LED is on or off, as follows.
If the switch LED is off, pressing the switch once will select its memory and its LED will flash.
If the switch LED is on, you’ll need to press the switch for at least five seconds in order to select its memory,
and its LED will flash quickly.
If you want to cancel your selection and choose another memory, press the switch again, or press the VC12’s RECALL switch. The switch’s LED will stop flashing.
Note: Previously stored program data will be overwritten by the next step and there is no undo. That is why
we recommend using the switch #4 area that is empty the first time you try this out.
5. To store the program data to the selected memory, press the Valvetronix amps [WRITE] button.
The data is transferred from the Valvetronix amp and stored in the VC-12. The corresponding switch LED (1-
4) comes on, indicating that the memory now contains data.