This document supports the version of each product listed and
supports all subsequent versions until the document is replaced
by a new edition. To check for more recent editions of this
document, see http://www.vmware.com/support/pubs.
EN-000710-02
Page 2
VMware vFabric Data Director Installation Guide
You can find the most up-to-date technical documentation on the VMware Web site at:
http://www.vmware.com/support/
The VMware Web site also provides the latest product updates.
If you have comments about this documentation, submit your feedback to:
VMware is a registered trademark or trademark of VMware, Inc. in the United States and/or other jurisdictions. All other marks
and names mentioned herein may be trademarks of their respective companies.
VMware, Inc.
3401 Hillview Ave.
Palo Alto, CA 94304
www.vmware.com
2 VMware, Inc.
Page 3
Contents
About VMware vFabric Data Director5
Updated Information7
Installation Prerequisites and vSphere Setup9
1
Prerequisites for Data Director 9
vSphere Settings for Data Director 11
Planning the Network Configuration15
2
Network Configurations for vFabric Data Director 15
Relating Networks in vSphere and Data Director 17
Data Director Networks, IP Allocation, and Firewalls 17
Four VLAN Network Configuration 20
Minimum Two VLAN Network Configuration 22
Deploy the Data Director vApp25
3
Start the Wizard and Specify vApp Properties 26
Specify Network Mappings and Network Properties 26
Finish Data Director vApp Deployment 27
Set Up Data Director29
4
Start the Data Director Setup Wizard 30
Accept the License Agreement 30
Create the Initial Data Director System Administrator Account 31
Set User Management Mode 31
Configure the Branding Settings 32
Configure SMTP Settings 32
Configure the vCenter Network and Its Network Adapters 32
Configure Network Mapping 33
Configure Networks and Network Adapters 33
Enter License Information 34
Review Data Director Setup 34
vFabric Data Director Upgrade35
5
About the vFabric Data Director Upgrade Process 35
Data Director Upgrade Virtual Appliance Process Overview 36
Data Director Upgrade Database Virtual Machines Process Overview 36
Upgrade a Data Director Virtual Appliance 36
Upgrade Data Director Database Virtual Machines (DBVMs) 41
Index43
VMware, Inc. 3
Page 4
VMware vFabric Data Director Installation Guide
4 VMware, Inc.
Page 5
About VMware vFabric Data Director
The VMware vFabric Data Director Installation Guide provides information about installing VMware® vFabric
Data Director, including configuring networks, deploying Data Director in vSphere Client as a virtual
appliance (vApp) running on a vCenter Server, and performing setup and configuration using the Data
Director administration UI.
The Data Director software solution enables you to manage an environment with large numbers of databases,
and offers application developers self-service database creation and resource allocation. Data Director supports
flexible, policy-based resource management, and provides resource isolation at the organization and database
levels. Data Director enables you to implement security policies through role-based access control. You can
delegate and grant customizable roles and privileges to specify users' allowed actions.
Self-service database lifecycle management enables application developers to create new databases, manage
schemas, set up backups, perform restores, clone databases for testing and development, scale database sizes
up, and decommission databases. Customizable database configuration and backup templates enable
administrators to control database parameters and enforce resource allocation policies, while simplifying
database creation and resource allocation for application developers.
Intended Audience
This document is for administrators and application developers.
n
System administrators use this document to learn about managing and monitoring a Data Director
environment. System administrators create organizations, allocate resources to them, and perform other
high-level tasks.
VMware, Inc.
n
Organization administrators use this document to learn about managing and monitoring database groups
and databases. Organization administrators can use and customize database templates, can assign
resources, and can monitor their organization.
n
Application developers use this document to learn about managing and monitoring databases.
5
Page 6
VMware vFabric Data Director Installation Guide
6 VMware, Inc.
Page 7
Updated Information
This vFabric Data Director Installation Guide is updated with each release of the product or when necessary.
This table provides the update history of the vFabric Data Director Installation Guide.
RevisionDescription
EN-000710-02
EN-000710-01
EN-000710-00 Initial release.
n
The topic, “Prerequisites for Data Director,” on page 9 clarifies the number of vCPUs that Data
Director supports.
n
The topic Chapter 5, “vFabric Data Director Upgrade,” on page 35 describes how to upgrade the Data
Director virtual appliance and database virtual machines (DBVMs).
VMware, Inc. 7
Page 8
VMware vFabric Data Director Installation Guide
8 VMware, Inc.
Page 9
Installation Prerequisites and vSphere
Setup1
Before you start installing Data Director, you must understand the environment requirements, you must set
up vSphere, and you must determine your networking configuration.
This chapter includes the following topics:
n
“Prerequisites for Data Director,” on page 9
n
“vSphere Settings for Data Director,” on page 11
Prerequisites for Data Director
Before you can install and run Data Director, your environment must meet the software, tools, and hardware
prerequisites.
n
vSphere 5.0 Enterprise or vSphere Enterprise Plus
n
VMware vSphere Client
n
VMware vCenter Server 5.0 and modules (ISO or ZIP)
n
ESXi ISO or ESXi offline bundle ZIP
n
vSphere Update Manager
n
vSphere VMFS-5
n
VMware Virtual Hardware 7
n
vFabric Data Director. Download the following client tools and drivers from the Data Director Download
page.
n
Data Director Client Tools (Linux 32-bit or 64-bit)
n
Data Director JDBC drivers
n
Web browser. Use one of the following.
n
Firefox 3.6 or later
n
Internet Explorer 7 or later
n
Flash Player 10.1 or later
The following are the minimum requirements for Data Director.
n
2 ESXi servers with 12GB of RAM combined.
n
1 vCenter Server system (can be running on a virtual machine).
n
1 Windows system for running vSphere Client.
VMware, Inc.
9
Page 10
VMware vFabric Data Director Installation Guide
n
40GB of shared storage, configured as two datastores.
n
1 Gigabit Ethernet VLAN.
This VLAN will carry Data Director network traffic.
n
One or more Gigabit Ethernet VLANs for one or more database networks.
Database networks carry SQL traffic to and from Data Director databases. Database clients such as JDBC
and libpq send and receive SQL traffic from database servers on these networks. Data Director supports
multiple database networks for better network isolation, for example, to isolate QA SQL traffic from
production SQL traffic. See Chapter 2, “Planning the Network Configuration,” on page 15.
n
Hardware to run the test application.
Check with your company's network administrators or IT staff to determine a setup that is appropriate for
your organization. For example, one possible setup for a 4-VLAN configuration is as follows.
n
4 ESXi servers with 64GB of RAM combined.
n
1 vCenter Server.
n
1 Windows system for running vSphere Client.
n
500GB of shared storage configured as two or more datastores.
n
4 Gigabit Ethernet VLANs.
These Gigabit Ethernet VLANs will carry Data Director network traffic.
n
One or more Gigabit Ethernet VLANs for one or more database networks.
Database networks will carry SQL traffic to and from Data Director databases. Database clients such as
JDBC and libpq send and receive SQL traffic from database servers on these networks. Data Director
supports multiple database networks for better network isolation, for example, to isolate QA SQL traffic
from production SQL traffic. See Chapter 2, “Planning the Network Configuration,” on page 15.
n
Hardware to run the test application
Data Director licensing supports up to 8 vCPUs.
Data Director provides several database configuration templates in different sizes: tiny, small, medium, large,
and giant. You can estimate the resources that your Data Director deployment requires based on your
installation's expected database sizes. For example, a database instance that uses the Tiny database
configuration template has the following settings.
Table 1-1. Settings for a Tiny Database Configuration
ResourceSetting
vCPUs1
Memory size512MB
Recommended database storage allocation5GB
For a base installation that uses the Tiny database template, use a cluster with the following CPU and memory
resources.
Table 1-2. Resource Requirements for a Base Installation Using the Tiny Database Template
ResourceRequirements
CPU4GHz and an additional 400 MHz for each database instance
Memory8GB of available memory and an additional 512 MB of available memory for each database instance
10 VMware, Inc.
Page 11
vSphere Settings for Data Director
Before you can install Data Director, set up the vSphere Cluster to deploy Data Director to, and enable the
cluster for vSphere High Availability (HA), and vSphere Dynamic Resource Scheduler (DRS). Data Director
also requires that you have Network Time Protocol (NTP) enabled in your environment.
Create and Configure the Data Director Cluster
A cluster is a group of hosts. When a host is added to a cluster, the host's resources become part of the cluster's
resources. Clusters enable the vSphere High Availability (HA) and vSphere Distributed Resource Scheduler
(DRS) solutions. Cluster settings must be compatible with Data Director.
Before you can install Data Director, you must create a vSphere cluster for use by Data Director. See also the
vSphere Resource Management documentation and the vSphere Availability documentation.
Prerequisites
n
Connect to the vCenter Server system by using a vSphere Client. You cannot create clusters if the client is
connected directly to a host.
n
Verify that you have sufficient permissions to create a cluster.
n
Verify that a datacenter exists in the vCenter Server inventory.
Chapter 1 Installation Prerequisites and vSphere Setup
Procedure
1In the vSphere Client, select Home > Inventory > Hosts and Clusters.
2Right-click a datacenter or a folder within a datacenter and select New Cluster.
3Complete the Cluster Features page.
aName the cluster.
bSelect the Turn On vSphere HA and Turn On vSphere DRS check boxes.
vSphere DRS must be enabled. Do not change this setting.
cClick Next.
In DRS clusters, Storage I/O Control is enabled by default. Do not change this setting.
4On the vSphere DRS page, set the automation level to Partially automated and click Next.
5On the Power Management page, leave power management set to Off or select a power management
setting appropriate for your environment, and click Next.
6On the vSphere HA page, select the HA settings required for the Data Director cluster and click Next.
OptionDescription
Host Monitoring Status
Admission Control
Admission Control Policy
Leave Enable Host Monitoring selected.
Leave Enable selected.
Specify a policy suitable for your environment. See the vSphere HighAvailability documentation.
VMware, Inc. 11
Page 12
VMware vFabric Data Director Installation Guide
7On the Virtual Machine Options page, select the settings required for the Data Director cluster settings
and click Next.
OptionDescription
VM Restart Priority
Host Isolation Response
8On the VM Monitoring page, select the following settings and click Next.
OptionDescription
VM Monitoring
Default Cluster Settings
9Finish the cluster setup.
aLeave VMware Enhanced vMotion Compatibility disabled and click Next.
bLeave the swap file location at its default and click Next.
cReview the cluster settings and click Finish.
What to do next
Any option that does not disable VM restart priority is acceptable. Data
Director requires that VM restart priority is enabled.
Leave the default or change the setting to support your environment.
Select VM and Application Monitoring.
Leave the monitoring sensitivity at the default.
You can customize the cluster even further to suit your environment requirements. See the vFabric Data DirectorAdministrator and User Guide.
Enable vSphere Network Time Protocol
The Network Time Protocol (NTP) daemon ensures that time-dependent processes occur in sync across hosts.
Enable the NTP daemon on the ESXi hosts.
Prerequisites
Verify that the ESXi hosts in the Data Director clusters are running.
Procedure
1Using a vSphere Client, connect to the vCenter Server system that manages the ESXi hosts in the Data
Director cluster.
2In the left navigation pane, select one of the hosts.
3In the main pane, click the Configuration tab, and click Time Configuration.
4Click Properties and click Options.
5Click NTP Settings and click Add.
6In the Add NTP Server dialog box, type a valid NTP server address and click OK.
7Select the Restart NTP service to apply changes check box and click OK.
8In the Time Configuration dialog, confirm that the NTP Client Enabled check box is selected.
n
If it is selected, click OK.
n
If it is not selected, click the Options button. In the Service Commands section of the NTP Daemon
(ntdp) Options dialog, click Start and click OK.
9Repeat for the other hosts in the Data Director cluster.
12 VMware, Inc.
Page 13
Chapter 1 Installation Prerequisites and vSphere Setup
Virtual Switches and Port Groups in vSphere
You create virtual switches and port groups in vSphere for use in Data Director.
vSphere port groups correspond to networks in Data Director. You can later allocate the vSphere port groups
for resource bundles for the Data Director Management Server or DB Access Networks. See the vFabric DataDirector Administrator and User Guide.
VMware, Inc. 13
Page 14
VMware vFabric Data Director Installation Guide
14 VMware, Inc.
Page 15
Planning the Network Configuration2
When you install Data Director, the installer prompts you for the IP addresses for the different networks in
the Data Director environment. Data Director network traffic runs on several different networks. Before you
start the installation, review the supported Data Director network configurations and plan your Data Director
network configuration.
Work with your enterprise's network and IT staff and use the vFabric Data Director Worksheets to plan and
implement the VLANs, virtual switches, and port groups (networks) that will carry Data Director network
traffic.
For information about vSphere networking, see the vSphere Networking documentation.
This chapter includes the following topics:
n
“Network Configurations for vFabric Data Director,” on page 15
n
“Relating Networks in vSphere and Data Director,” on page 17
n
“Data Director Networks, IP Allocation, and Firewalls,” on page 17
n
“Four VLAN Network Configuration,” on page 20
n
“Minimum Two VLAN Network Configuration,” on page 22
Network Configurations for vFabric Data Director
The Data Director system carries different types of network traffic on different networks. To prepare your
network worksheet, you must understand the different networks and servers in the Data Director environment.
Data Director Management Server and DB Name Server
Data Director deploys the Management Server and a DB Name Server on virtual machines.
Management Server
DB Name Server
VMware, Inc. 15
The Management Server performs all management operations.
The DB Name Server provides the DB Name Service. The DB Name Service
provides a single entry point to databases. When Data Director creates a vFabric
Postgres (vPostgres) database, it provides a connection string for that vPostgres
database. The connection string contains the DB Name Service IP address, port,
database server id, database name, and user name.
Page 16
VMware vFabric Data Director Installation Guide
Data Director Networks
Data Director uses the following networks to carry different types of network traffic.
When a database client or application wants to connect to a vPostgres database
using the Data Director JDBC or libpq drivers, the driver retrieves the database
IP address from the DB Name Server using the connection string. The driver
sets up the connection between the application and the target database. When
you use the application to access the database, the application uses that
connection. This means that the DB Access Network must be visible from all
database clients.
The advantage provided by DB Name Service is that the database applications
are not affected when the database server's IP address changes. This enables
databases to use dynamic IP addresses from a DHCP server and lowers
management costs.
vCenter Network
Carries management traffic between vCenter Server and the Data Director
Management Server. This network carries commands that the Management
Server uses to interact with vCenter Server and all the ESXi hosts managed by
that vCenter Server.
Internal Network
Carries internal management traffic among vPostgres databases, the Data
Director Management Server, and the DB Name Server. Due to security
considerations, internal management traffic must have its own network, it
cannot share a network with other types of traffic, and it must have DHCP
enabled.
Web Console Network
Carries traffic between Web clients (console) and the Data Director
Management Server.
DB Name Service
Network
Carries traffic for the name service for vPostgres databases. The DB Name
Server performs database name to IP address translation (database connection
services) and must be reachable from database clients.
DB Access Networks
Data Director includes one or more DB Access Networks for carrying SQL
traffic between database clients and vPostgres databases' virtual machines
(DBVMs). Each DB Access Network must have DHCP enabled.
Traffic for more than one Data Director network can be on the same physical network. For example, vCenter
Network traffic can share the identical vSphere network with the Web Console Network traffic.
Some possible network configurations are as follows.
n
Four separate networks, one for carrying each type of Data Director network traffic, plus one or more
networks for carrying database (SQL) network traffic to and from vPostgres databases. See “Four VLAN
Network Configuration,” on page 20.
n
Two networks, one for carrying database (SQL) network traffic and one shared network that carries all
Data Director Management Server network traffic. This configuration is the minimum network
configuration. See “Minimum Two VLAN Network Configuration,” on page 22.
Database clients, such as the PgAdmin tool, send and receive SQL traffic from database servers on the DB
Access Network. Data Director supports more than one database network VLAN for better network isolation,
for example, to isolate QA SQL traffic from production traffic.
16 VMware, Inc.
Page 17
If you set up two separate database networks, the database network traffic can use the vCenter Network, Web
Console Network, or DB Name Server Network. Placing database traffic in the same network for vCenter, Web
Console, or DB Name Server can carry a security risk.
You can have as many database networks as your site requires. However, database clients must have access
to the DB Name Service Network.
Relating Networks in vSphere and Data Director
Data Director components communicate by using vSphere networking resources. Before you start planning
your network, you must understand vSphere and Data Director networking.
Data Director requires networks to carry communications among its components, including the following.
n
Communication between the Data Director Management Server and database servers.
n
Communication between database servers and applications.
n
Communication between the Data Director DB Name Server and applications.
vSphere administrators create switches and networks for each ESXi host. As a vSphere administrator, you can
either designate existing networks for Data Director use, or create and configure networks for Data Director
use. These networks will be used for the Management Server and for one or more DB Access Networks.
You specify the different networks at different times in the installation and setup process.
Chapter 2 Planning the Network Configuration
vCenter Network and
Web Console Network
Internal Network and DB
Name Service Network
DB Access Network
Best practice is to set up your Data Director networks as separate subnets, such as using different VLANs, to
provide the best security. Use VLANs with 1-Gigabit or higher speed Ethernet interfaces.
In addition to network setup, you must also open certain ports in your firewall. See “Data Director Networks,
IP Allocation, and Firewalls,” on page 17.
You specify the vSphere port groups (networks) to use for vCenter Network
and Web Console Network during Data Director vApp deployment.
NOTE Set up vSphere Update Manager to use the vCenter Network to
communicate with Data Director. If vSphere Update Manager uses a different
network, it cannot function properly.
You set up the Internal Network and DB Name Service Network after the Data
Director vApp deploys, during the Data Director setup process. See “Configure
Network Mapping,” on page 33. DHCP must be enabled on these networks.
A DB Access Network is the interface to the database virtual machines
(DBVMs) and carries SQL traffic. DBVMs run the actual databases and are
created when users create databases. DHCP must be enabled on DB Access
networks. You can configure as many DB Access networks as there are
databases. You select the vSphere networks to use for the DB Access Network
when you create resource bundles. See the vFabric Data Director Administratorand User Guide.
Data Director Networks, IP Allocation, and Firewalls
To plan your network, you must understand DNS Server requirements and know which firewall ports must
be open for Data Director traffic. This section describes DNS server requirements, firewall ports and the
network traffic they carry, and network configuration requirements.
The Data Director vApp requires the use of DHCP IP address allocation policy. Set up a DHCP server for the
Internal Network and the DB Access Network. If you select a static IP address for the Web Console Network
adapter on the Management Server, a DHCP server on the Web Console Network is not required.
VMware, Inc. 17
Page 18
VMware vFabric Data Director Installation Guide
You can assign static IP addresses to the DB Name Service Network Adapter on the DB Name Server and the
vCenter Network adapters on both the Management Server and the DB Name Server. DHCP service is not
required on their corresponding networks.
Data Director network configuration depends upon your existing network configuration. Consult with your
network or IT administrators and use the vFabric Data Director Worksheets to record the network settings, IP
addressing methods, and IP addresses that must set up Data Director networks and network adapters.
Some points to consider are as follows.
n
The DNS server, netmask, and gateway are properties of a vSphere network. As part of network
configuration, you might be asked to specify information about the DNS server, netmask, and gateway.
n
If your network uses DHCP IP address allocation, the DHCP server supplies IP addresses for these
properties during DHCP configuration.
n
If your network uses static IP address allocation, you will be asked to supply a subset of the IP
addresses for the DNS server, netmask, and gateway.
n
During Data Director vApp deployment, you configure the Management Server - Web Console Network
Adapter. This is how users connect to the Data Director web UI.
n
The Management Server Network gateway and DNS server information is configured with the Web
Console Network Adapter's configuration.
n
The DB Name Service Server's network gateway and DNS server information is configured with the DB
Name Service Network Adapter's configuration.
n
If a vSphere network is used by multiple Data Director networks, information that was already specified
and cannot be changed is displayed but is grayed out.
n
The use of DHCP-assigned addresses for certain adapters requires the use of Dynamic DNS so that FQDNs
specified during configuration can be mapped to dynamically assigned IP addresses. See “IP Address and
DHCP Setup,” on page 20 for details.
n
If you deploy Data Director with a static IP address for the Web Console Network, specify the central DNS
server in the network properties.
Firewall Ports to Open For Data Director Network Traffic
Data Director requires that you open specific ports on your firewall to handle Data Director network traffic.
The following tables list the ports to open on your firewall to handle outgoing and incoming Data Director
network traffic.
Firewall Ports for Outgoing Data Director Network Traffic
The following table lists the ports to open on your firewall to handle outgoing Data Director network traffic.
18 VMware, Inc.
Page 19
Chapter 2 Planning the Network Configuration
Table 2-1. Data Director vApp Outgoing Network Traffic
Firewall Ports for Incoming Data Director Network Traffic
The following table lists the ports to open on your firewall to handle imcoming Data Director network traffic.
Table 2-2. Data Director vApp Incoming Network Traffic
To
FromTo
AnyDB Name Server - DB Name Service Network
Adapter
AnyManagement Server - Web Console network
adapter
Any
vCenter Update
Manager on
vCenter
n
DB Access Network 1
n
DB Access Network 2
n
...
n
DB Access Network n
n
DB Name Server - vCenter Network Adapter
n
Management Server - vCenter Network
Adapter
Network
portTraffic type
5432Incoming database traffic, including
PostgreSQL traffic.
80,443Web Console traffic.
5432Incoming database traffic, including
PostgreSQL traffic.
5489Incoming update traffic from the vCenter
Update Manager to the Management
Server and DB Name Server networks'
update agents.
VMware, Inc. 19
Page 20
VMware vFabric Data Director Installation Guide
IP Address and DHCP Setup
This section provides information about the requirements for Data Director IP address and DHCP setup.
IP Address and DHCP Setup for Data Director Network Traffic
Table 2-3. Required IP Addresses and DHCP Setup
DHCP
Data Director
Networks
vCenter Network no
Internal Network yes
Web Console
Network
DB Name Service
Network
DB Access
Networks
Require
dIP AddressFQDN
no1 IP address used by the Data Director Management Server. This
no1 IP addresses used by Data Director DB Name Server. This IP
yesn IP addresses used by the database virtual machines (DBVMs).
n
1 IP address used by the Data Director Management Server.
n
1 IP Address used by the Data Director DB Name Server.
n
1 IP address used by the Data Director Management Server.
n
1 IP Address used by the Data Director DB Name Server.
n
n IP addresses used by the database virtual machines
(DBVMs). These IP addresses must be assigned by the
DHCP server.
For the Data Director Management Server, these IP addresses
can be static or assigned by the DHCP server.
IP address can be static or assigned by the DHCP server.
address can be static or assigned by the DHCP server.
These IP addresses must be assigned by the DHCP server and
DB Name Server.
Not required.
Required only if you
cannot provide two
static IP addresses, in
which case Dynamic
DNS is required.
One FQDN.
One FQDN.
Not required.
Multiple-Gateway Network Setups
You can configure the Management Server virtual machine and the DB Name Server virtual machine with one
network gateway.
The Management Server virtual machine uses the gateway associated with its Web Console Network Adapter.
The DB Name Server virtual machine uses the gateway associated with its DB Name Service Network Adapter.
If any network traffic that originates from the Management Server and DB Name Server virtual machines
requires routing, that routing can be done only through the configured gateway. Network setups that require
more than one gateway in either the Management Server or DB Name Server virtual machine are not currently
supported and cannot be configured.
Four VLAN Network Configuration
A possible network configuration is to have four separate VLANs for the different types of Data Director
network traffic and one or more separate DB Access Networks for database (SQL) network traffic. This
configuration requires 1-Gigabit or greater Ethernet interfaces.
The following diagram illustrates a four-VLAN network configuration.
20 VMware, Inc.
Page 21
Figure 2-1. A Four-VLAN Network Diagram
Data Director
Web Console
vFabric Data Director vApp
vCenter Network
Management
Server
DB Name
Server
Internal Network (DHCP required)
vFabric Postgres VMs
1 to N DB Access Networks (DHCP required)
database
client
DB Name Service Network
database
client
database
client
Web Console Network
vCenter Network
Internal Network
(DHCP required)
DB Name Service Network
DB Access Networks
(DHCP required)
network adapter
(configured during setup)
vCenter
Server
ESXi host
Web Console
Network
vSphere Update
Manager Server
Chapter 2 Planning the Network Configuration
This example configuration uses four VLANs with DHCP servers mapped in the Data Director setup wizard
after the Deploy OVF Template wizard successfully completes.
n
One VLAN mapped to the vCenter Network, which carries Management Server traffic between vCenter
Server, the Data Director Management Server, and the DB Name Server. The Data Director Management
Server acquires virtual resource information over this network. vSphere Update Manager (VUM)
communicates with the DB Name Server to get the database server IP address through the vCenter
Network.
n
One VLAN mapped to the Internal Network, which carries management traffic between the Data Director
Management Server and the agents running in the database virtual machines (DBVMs), and DB Name
Server traffic between the database virtual machines and the LDAP Server when an IP address changes.
A DHCP Server is required on the Internal Network.
n
One VLAN mapped to the Web Console Network, which carries Data Director UI traffic to a web browser.
The Web Console network adapter is defined in the Data Director vApp. Any Web client that will use the
Data Director Management Server must have access to this network using HTTPS.
VMware, Inc. 21
Page 22
VMware vFabric Data Director Installation Guide
n
One VLAN mapped to the DB Name Service Network enables database client applications to connect to
DBVMs. The clients request the database virtual machine IP address from the DB Name Server using the
DB Name Service network. The DB Name Server provides connection information to a database client
application, which then connects to the database using its Database Access Network. Any database client
that will issue SQL traffic to a database managed by Data Director must have access to this network using
port 389.
In addition, DB Access Networks carry SQL traffic between database client applications and the vPostgres
databases. These networks are not defined at installation. DB Access Networks are made available when Data
Director system administrators define resource bundles in the Data Director UI and assign the resource bundles
to organizations. A DHCP Server is required on the DB Access Networks. Set aside at least one network for
the DB Access Network.
Minimum Two VLAN Network Configuration
A minimum network configuration includes one network to carry Internal Network traffic, and one network
for all other traffic. This setup requires two networks with 1-Gigabit or greater Ethernet interfaces.
NOTE Avoid single-network configurations. Because of security considerations, place the Internal Network
on its own isolated vSphere network.
The following diagram illustrates a two-VLAN network configuration.
22 VMware, Inc.
Page 23
Figure 2-2. A Two-VLAN Network Diagram
Data Director
Web Console
vFabric Data Director vApp
vCenter Network
Management
Server
DB Name
Server
Internal Network (DHCP required)
vFabric Postgres VMs
1 DB Access Network (DHCP required)
Database
Client
DB Name Service Network
Internal Network
(DHCP required)
vCenter Network
Web Console Network
DB Name Service Network
1 DB Access Network
(DHCP required)
Network adapter
(configured during setup)
VLAN 1
VLAN 2
vCenter
Server
ESXi host
Web Console
Network
vSphere Update
Manager Server
Database
Client
Database
Client
Chapter 2 Planning the Network Configuration
Traffic on Each VLAN
Required IP Addresses and DHCP Setup
The two VLANs carry the following traffic.
n
One VLAN is for the shared network for vCenter, Web Console, DB Name Service, and DB Access
Networks.
n
One VLAN is for the Internal Network. This VLAN carries internal management traffic between databases,
the Data Director Management Server, and the DB Name Server. The Internal Network must be a VLAN.
This minimum configuration requires DHCP on the shared (vCenter Server/Web Console/Internal) and DB
Access networks. To handle internal management traffic, the network DHCP range should have at least as
many IP addresses as the number of databases. See “Data Director Networks, IP Allocation, and Firewalls,”
on page 17.
VMware, Inc. 23
Page 24
VMware vFabric Data Director Installation Guide
Limitations
Using only two VLANs has some limitations.
n
Because all vCenter Network traffic, Web Console Network traffic, and SQL traffic is carried by one
network, you cannot isolate databases into different networks.
n
vCenter Server, ESXi hosts, and Data Director Management Server traffic is exposed to regular database
users, which can introduce security risks.
24 VMware, Inc.
Page 25
Deploy the Data Director vApp3
The Data Director OVA file contains the compressed open virtualization format files that compose the Data
Director vApp. After setting up vSphere and planning the network configuration, download the Data Director
OVA file and deploy it as a vSphere virtual appliance (vApp).
Before you start deployment, you must know how you will map the networks in the Data Director vApp to
the networks in your vSphere inventory and have the mappings at hand, including the fully qualified domain
names (FQDNs) or the IP addresses for each of the Data Director networks. See the vFabric Data DirectorWorksheets.
Prerequisites
n
Log in to vSphere Client as an administrator.
n
Verify that DHCP is enabled in your vSphere installation.
n
Verify that the cluster you created for Data Director deployment meets all requirements. See “Create and
Configure the Data Director Cluster,” on page 11.
n
Verify that the ESXi hosts in the Data Director cluster are running.
n
Verify that NTP has been set up in the environment. See “Enable vSphere Network Time Protocol,” on
page 12.
VMware, Inc.
Procedure
1Start the Wizard and Specify vApp Properties on page 26
In this first part of Data Director OVA deployment, you specify basic information about the product,
including its name, location, and storage.
2Specify Network Mappings and Network Properties on page 26
As part of vApp deployment, you have to specify the vSphere Networks that Data Director uses for its
vCenter Network and its Web Console Network. You also have to specify the FDQN to connect to the
Web Management console and, if you are using static IP, the static IP address.
3Finish Data Director vApp Deployment on page 27
The Data Director vApp must be bound to a service to enable it to register as a vCenter extension at
runtime. To finish Data Director vApp deployment, you select a service binding for the Data Director
vApp, and confirm the deployment settings.
25
Page 26
VMware vFabric Data Director Installation Guide
Start the Wizard and Specify vApp Properties
In this first part of Data Director OVA deployment, you specify basic information about the product, including
its name, location, and storage.
Prerequisites
You will select the disk format for the vApp virtual disks as part of deployment. For information about the
supported disk formats and their trade-offs, see the vSphere Storage documentation or the VMware Knowledge
Base article Using thin provisioned disks with virtual machines.
Procedure
1In vSphere Client, right-click the cluster in which to deploy the Data Director vApp.
2Select File > Deploy OVF Template.
3Answer the prompts from the wizard.
Wizard ScreenAction
Source
OVF Template Details
Name and Location
Resource Pool
Storage
Disk Format
Enter or browse to the location of your Data Director vApp OVA file.
Confirm the product information.
Specify a name and select the target datacenter for your deployment.
Select the cluster to which you want to deploy this vApp. If you select the
cluster, the vApp is deployed to the cluster's root resource pool. If the cluster
has child resource pools, you can choose one of the child resource pools.
Select a destination storage for the Data Director files.
Select the disk format for the vApp virtual disks.
What to do next
Click Next to continue to “Specify Network Mappings and Network Properties,” on page 26.
Specify Network Mappings and Network Properties
As part of vApp deployment, you have to specify the vSphere Networks that Data Director uses for its vCenter
Network and its Web Console Network. You also have to specify the FDQN to connect to the Web Management
console and, if you are using static IP, the static IP address.
Prerequisites
Specify vApp properties in the Deploy OVF Template Wizard. See “Start the Wizard and Specify vApp
Properties,” on page 26.
Prepare your network setup worksheets. See the vFabric Data Director Worksheets.
26 VMware, Inc.
Page 27
Procedure
1In the Network Mapping screen, choose the vSphere networks that will carry traffic for the two Data
Director Networks.
Table 3-1. Data Director Networks
Data Director NetworkDescription
vCenter NetworkThe vCenter Network carries management traffic between vCenter Server and the
Data Director Management Server. Select the vSphere Network that you decided to
use for this traffic.
Web Console NetworkThe Web Console Network carries traffic between web clients and the Data Director
Management Server. Select the vSphere Network that you decided to use for this
traffic.
If you are using static IP addresses, enter the values for Static IP Address, Netmask, Gateway, DNS Server
1, and optionally DNS Server 2 from your worksheet. If you are using DHCP, leave these fields at the
preset values.
2Click Next to continue.
Finish Data Director vApp Deployment
The Data Director vApp must be bound to a service to enable it to register as a vCenter extension at runtime.
To finish Data Director vApp deployment, you select a service binding for the Data Director vApp, and confirm
the deployment settings.
Chapter 3 Deploy the Data Director vApp
Procedure
1In the Configure Service Bindings screen, left-click the vCenter Extension service binding, select the service
binding, and click Next.
2Review the settings, and change settings if necessary.
3(Optional) Select the Power on after deployment check box to power up Data Director when deployment
is complete.
4Click Finish to confirm the settings and start the Data Director vApp deployment process.
The Data Director vApp deploys on the designated cluster and powers up. This process can take a few minutes.
The deployed Data Director vApp appears in the vSphere host's inventory list. When you expand the vApp,
you see the following Data Director virtual machines.
n
Management Server
n
DB Name Server
What to do next
Set up Data Director. See Chapter 4, “Set Up Data Director,” on page 29.
VMware, Inc. 27
Page 28
VMware vFabric Data Director Installation Guide
28 VMware, Inc.
Page 29
Set Up Data Director4
After you successfully deploy the Data Director vApp, you configure Data Director using the Data Director
setup wizard. As part of the setup process you specify user management mode, network mapping, and license
information.
Prerequisites
n
Complete the network planning for your environment. See the vFabric Data Director Worksheets.
n
Deploy the Data Director vApp.
Procedure
1Start the Data Director Setup Wizard on page 30
You start the setup wizard from a Web browser. You must know the FQDN of the Management Server
to start the wizard.
2Accept the License Agreement on page 30
When you connect to Data Director for the first time, the VMware End User License Agreement appears.
Before you set up Data Director, read and accept the license agreement.
3Create the Initial Data Director System Administrator Account on page 31
The initial Data Director system administrator performs Data Director setup and configuration, creates
other system administrators and organization administrators, creates and allocates resources for
organizations, and monitors resource usage. You specify the initial Data Director system administrator
account when you connect to Data Director for the first time.
VMware, Inc.
4Set User Management Mode on page 31
User management mode controls how users are assigned and managed across different organizations in
Data Director. You must understand the choices because you cannot change them after you set them.
5Configure the Branding Settings on page 32
You can optionally specify branding information that will appear on Data Director page headers and in
the login screen. Branding information includes your company name, logo, and About and Support
URLs.
6Configure SMTP Settings on page 32
You configure SMTP settings to enable Data Director to send notification emails to users. Notifications
such as alarms might go to system administrators. Notifications, such as registration confirmation and
password change emails, might enable self-registration.
7Configure the vCenter Network and Its Network Adapters on page 32
Data Director uses the vCenter Network to communicate with the vCenter Server system. You configure
the vCenter Network and its network adapters to enable this communication.
29
Page 30
VMware vFabric Data Director Installation Guide
8Configure Network Mapping on page 33
The Network Mapping screen of the setup wizard allows you to map the vSphere networks to the type
of Data Director network traffic they will carry.
9Configure Networks and Network Adapters on page 33
To allow the Management Server and DB Name Server to communicate by using the Internal and DB
Name Service Networks, you set up the network settings and configure the adapters.
10 Enter License Information on page 34
Data Director offers evaluation and permanent licenses, with database usage designated as production
or nonproduction.
11 Review Data Director Setup on page 34
The setup wizard's Summary screen allows you to review your configuration, make changes, and
complete the setup process.
Start the Data Director Setup Wizard
You start the setup wizard from a Web browser. You must know the FQDN of the Management Server to start
the wizard.
Procedure
1Find the Data Director FQDN.
aLog in to the vSphere Client as an administrator.
bIn the inventory list in the left pane, expand the Data Director vApp and right-click the Management
Server virtual machine.
cClick Edit virtual machine settings.
dClick the Options tab, and click Properties.
The Data Director FQDN is the first property listed in the vApp Property Configuration window.
2Start the wizard by typing the following URL into a Web browser.
https://
The Data Director Setup wizard starts.
FQDN
/datadirector
Accept the License Agreement
When you connect to Data Director for the first time, the VMware End User License Agreement appears. Before
you set up Data Director, read and accept the license agreement.
Data Director is a licensed product. You must accept the end user license agreement to continue setting up
Data Director.
Procedure
1Use the scroll bar to read the entire Data Director license agreement.
2Click the I agree to the terms in the license agreement radio button to accept the agreement.
3Click Next to continue.
30 VMware, Inc.
Page 31
Chapter 4 Set Up Data Director
Create the Initial Data Director System Administrator Account
The initial Data Director system administrator performs Data Director setup and configuration, creates other
system administrators and organization administrators, creates and allocates resources for organizations, and
monitors resource usage. You specify the initial Data Director system administrator account when you connect
to Data Director for the first time.
Prerequisites
n
Complete the License Agreement acceptance in the Data Director Setup wizard.
n
Decide on the login and account information for the initial Data Director system administrator.
Procedure
1Type the system administrator email and password.
2Type the system administrator first and last name.
3(Optional) Enter a phone number.
4Click Next to continue.
Set User Management Mode
User management mode controls how users are assigned and managed across different organizations in Data
Director. You must understand the choices because you cannot change them after you set them.
Data Director offers the following user management modes.
Global user
management mode
By Organization user
management mode
Prerequisites
Complete the system administrator account setup in the Data Director Setup wizard.
Procedure
1Select the user management mode that you want to use in your Data Director installation.
2Click Next to continue.
Global user management mode is used by enterprises that plan to operate Data
Director internally only, and do not plan to allow access from users outside the
enterprise. In this mode, organizations can represent enterprise business units,
database groups can represent departments within the business units, and
databases pertain to the departments that the database groups represent.
Global user management mode is the default.
By Organization user management mode is used by service providers that plan
to host multiple enterprises within Data Director. In this mode, organizations
each represent self-contained, separate enterprises that cannot see each others'
users and have no visibility outside their own organization. By Organization
database groups can represent business units and departments within the
enterprise, and databases pertain to those business units and departments.
VMware, Inc. 31
Page 32
VMware vFabric Data Director Installation Guide
Configure the Branding Settings
You can optionally specify branding information that will appear on Data Director page headers and in the
login screen. Branding information includes your company name, logo, and About and Support URLs.
Prerequisites
Complete the User Management Mode selection in the Data Director Setup wizard.
Procedure
1(Optional) Add branding information for your company.
If you do not want to add branding information now, you can add it later.
2Click Next to continue.
Configure SMTP Settings
You configure SMTP settings to enable Data Director to send notification emails to users. Notifications such
as alarms might go to system administrators. Notifications, such as registration confirmation and password
change emails, might enable self-registration.
You can specify SMTP settings now or configure SMTP later. If you do not configure SMTP, Data Director
cannot send email to users.
Prerequisites
Complete the Branding Settings page in the Data Director Setup wizard.
Procedure
1Enter the SMTP settings for your environment.
2Click Next to continue.
Configure the vCenter Network and Its Network Adapters
Data Director uses the vCenter Network to communicate with the vCenter Server system. You configure the
vCenter Network and its network adapters to enable this communication.
Prerequisites
n
Plan the network setup for your environment. See the vFabric Data Director Worksheets.
n
Complete the SMTP settings in the Data Director Setup wizard.
Procedure
1Click the Edit button.
2Select the DHCP or Static IP check box.
You can select both check boxes if your environment supports both protocols.
3If you selected Static IP, enter a valid netmask.
4Click OK to accept the network settings.
5Enter the FQDN for the Management Server - vCenter Network adapter.
6Enter the FQDN for the DB Name Server - vCenter Network adapter.
7If you selected Static IP, enter the IP address for each adapter in the address text box.
32 VMware, Inc.
Page 33
8Click Next to continue.
Configure Network Mapping
The Network Mapping screen of the setup wizard allows you to map the vSphere networks to the type of Data
Director network traffic they will carry.
Prerequisites
n
Plan the network setup for your environment. See the vFabric Data Director Worksheets.
n
Complete the vCenter Network setup in the Data Director Setup wizard.
Procedure
1Use the Internal Network drop-down menu to configure the network mapping.
The Internal Network traffic must be on a different network than other network traffic.
2Use the drop-down menu for the other networks (Web Console, Internal, and DB Name Service Network)
to configure their network mapping.
During development and prototyping, you can use one network for these three types of network traffic.
In a production environment, each Data Director network must map to a different vSphere network.
3Click Next to continue.
Chapter 4 Set Up Data Director
Data Director setup maps the networks. This can take a few minutes. When mapping finishes, Data Director
setup continues to the Network Configuration screen.
Configure Networks and Network Adapters
To allow the Management Server and DB Name Server to communicate by using the Internal and DB Name
Service Networks, you set up the network settings and configure the adapters.
Prerequisites
n
Plan the network setup for your environment. See the vFabric Data Director Administrator and User Guide.
n
Complete the Network Mapping screen of the Data Director Setup wizard.
Procedure
1Click the Edit button.
2Select the DHCP or Static IP check box.
You can select both check boxes if your environment supports both protocols.
3If you selected Static IP, enter a valid netmask.
4Click OK to accept the network settings.
5Type the FQDN for the Management Server - Internal Network adapter.
6Type the FQDN for the DB Name Server - DB Name Service Network adapter.
7Type the FQDN for the DB Name Server - Internal Network adapter.
8If you selected Static IP, type the IP address for each adapter in the address text box.
9Click Next to continue.
Data Director setup maps the networks. This can take a few minutes. When mapping completes, Data Director
setup continues to the License screen.
VMware, Inc. 33
Page 34
VMware vFabric Data Director Installation Guide
Enter License Information
Data Director offers evaluation and permanent licenses, with database usage designated as production or
nonproduction.
See the vFabric Data Director Administrator and User Guide for a discussion of Data Director and vFabric Postgres
licensing.
Prerequisites
n
Obtain license keys for your Data Director products from your VMware representative.
n
Complete the Networks and Network Adapters page of the Data Director Setup wizard.
Procedure
1Enter Data Director and vFabric Postgres license keys in the License key text boxes.
2Click the Add License Keys button.
3Click Next to continue.
Review Data Director Setup
The setup wizard's Summary screen allows you to review your configuration, make changes, and complete
the setup process.
Procedure
1In the Summary screen, review the setup.
Some of the settings you specify, such as the user management mode and the initial Data Director
administrator account, cannot be changed after setup finishes.
2Click Back to make changes or Finish to accept your settings.
When configuration finishes, the Data Director login page appears.
What to do next
Log in using the administrator account that you set up and start using Data Director. See the vFabric Data
Director Administrator and User Guide.
34 VMware, Inc.
Page 35
vFabric Data Director Upgrade5
vFabric Data Director Upgrade describes how to upgrade the Data Director virtual appliance and database
virtual machines (DBVMs).
Upgrading is a multistage process in which you perform procedures in a particular order. Follow the process
to ensure a smooth upgrade with a minimum of system downtime. Follow the safeguards to avoid losing data
or access to Data Director. Without planning, you might incur more downtime than is necessary.
Before you begin the upgrade, verify that you completed the following tasks:
n
Your vFabric Data Director deployment is running in the VMware vSphere 5.0 environment.
n
VMware vSphere Update Manager 5.0 (VUM) is installed and available in that environment. Use VUM
to apply updates to Data Director.
n
Made backups of your Data Director vApp and database virtual machines.
For information about VMware vSphere Update Manager, see the vSphere Upgrade documentation.
This chapter includes the following topics:
n
“About the vFabric Data Director Upgrade Process,” on page 35
n
“Data Director Upgrade Virtual Appliance Process Overview,” on page 36
n
“Data Director Upgrade Database Virtual Machines Process Overview,” on page 36
n
“Upgrade a Data Director Virtual Appliance,” on page 36
n
“Upgrade Data Director Database Virtual Machines (DBVMs),” on page 41
About the vFabric Data Director Upgrade Process
The vFabric Data Director Upgrade involves two processes: upgrading the Data Director virtual appliance and
upgrading the database virtual machines (DBVMs). A particular upgrade might require that you upgrade only
the Data Director virtual appliance or that you upgrade the database virtual machines as well.
Use VMware vSphere Upgrade Manager (VUM) to upgrade the Data Director virtual appliance. Use the Data
Director Web-based administration UI to upgrade existing database virtual machines.
As part of configuring the Data Director virtual appliance upgrade, you specify a remediation task.
Remediation is the process in which VUM applies patches, extensions, and upgrades to vSphere objects such
as the Data Director virtual appliance.
Upgrading a virtual machine can require that the virtual machine is powered up, powered off, and rebooted
multiple times. You can specify when to apply the updates for powered on virtual machines, powered off
virtual machines, and suspended virtual machines.
VMware, Inc.
35
Page 36
VMware vFabric Data Director Installation Guide
Data Director Upgrade Virtual Appliance Process Overview
To upgrade vFabric Data Director virtual appliances, you log in to vSphere Client as an administrator and
perform upgrade tasks such as downloading the upgrade package, taking pre-upgrade snapshot backups, and
using vSphere Update Manager (VUM) to apply the upgrade.
The following process is the sequence of tasks for upgrading Data Director virtual appliances.
1Obtain the Data Director upgrade package.
2In the vSphere Client, take a snapshot backup of the Data Director virtual appliance.
3In the vSphere Client, start vSphere Update Manager (VUM) or connect to the VUM server.
4Download the upgrade package and accept the EULA.
5Define the upgrade baseline and attach it to the current Data Director virtual appliance.
6Verify that the Data Director virtual appliance needs to be updated by scanning the baseline and
comparing it with the virtual appliance.
7In the Data Director Web administration UI, shut down Data Director.
8In the vSphere Client, configure the upgrade remediation job and start the Data Director virtual appliance
upgrade.
If the Data Director virtual appliance upgrade succeeds, log in to the Data Director Web administration UI and
perform any necessary administration tasks.
If the Data Director virtual appliance upgrade does not complete, revert to the virtual machine snapshot that
you took earlier, fix the blocking issue, and restart the upgrade process.
If the Data Director upgrade includes updates to database virtual machines (DBVMs), see“Data Director
Upgrade Database Virtual Machines Process Overview,” on page 36.
Data Director Upgrade Database Virtual Machines Process Overview
Data Director upgrades can include upgrades to the database virtual machines (DBVMs). To upgrade database
virtual machines, you log in to Data Director as a system administrator, publish the new database virtual
machine template, and upgrade each database to the new template.
If a Data Director upgrade includes updates to database virtual machine templates, proceed as follows.
1Log in to the Data Director Web administration UI as an administrator and open the Administration tab.
2Publish the new database virtual machine template.
3For each database to upgrade:
aRight-click the database and select Upgrade.
bCheck the Upgrade to latest version check box.
cSpecify a start time.
The upgrade proceeds automatically.
Upgrade a Data Director Virtual Appliance
Administrators upgrade the Data Director virtual appliance from vSphere Client using VMware vSphere
Update Manager (VUM).
A new version of vFabric Data Director includes updates to the database virtual machine (DBVM) binaries.
You want to upgrade your Data Director database virtual machines to the latest version.
36 VMware, Inc.
Page 37
Chapter 5 vFabric Data Director Upgrade
Prerequisites
You are logged in to a vSphere Client as an administrator.
Verify that Data Director is deployed and running.
Verify that the VUM plugin is installed and available.
You took a snapshot backup of the Data Director vApp's virtual machines with a retention time of at least 1
day.
You obtained the upgrade source URL, either from an email notification or from your VMware representative.
Procedure
1Start vSphere Update Manager on page 37
Administrators use the vSphere Update Manager to perform upgrades and to apply patches.
2Configure Proxy Settings on page 38
If your site uses a proxy server to access the Web, configure the vSphere Update Manager to use the
proxy server. You need access to upgrade your Data Director virtual appliance.
3Download the Upgrade Source and Accept the EULA on page 38
To start the Data Director upgrade process, download the upgrade source from the URL supplied to you,
either in an email notification or by your VMware representative, and accept the EULA.
4Create an Upgrade Baseline on page 39
You upgrade virtual appliances by using a predefined virtual appliance upgrade baseline, or by creating
a custom virtual appliance upgrade baseline. Data Director virtual appliance upgrades require that you
create a custom virtual appliance upgrade baseline.
5Specify Upgrade Compliance Settings on page 39
Upgrade compliance settings ensure that the upgrade baseline does not conflict with the current state of
your Data Director virtual appliance.
6Shut Down Data Director on page 40
Certain administrative tasks require that you shut down Data Director. These tasks include applying
upgrades and patches. Data Director system administrators shut down Data Director using the Data
Director Web UI.
7Configure the Upgrade Remediation Task and Run the Upgrade Process on page 40
The upgrade remediation task is the process by which vSphere Update Manager applies patches,
extensions, and upgrades to the Data Director virtual appliance. Configure and run the remediation task
to complete the Data Director virtual appliance upgrade process.
Start vSphere Update Manager
Administrators use the vSphere Update Manager to perform upgrades and to apply patches.
Prerequisites
You received the URL for downloading the Data Director upgrade source.
Procedure
1Log in to vSphere Client as an administrator.
2On the Home page of the vSphere Client, select Hosts and Clusters.
3Click the Update Manager tab.
VMware, Inc. 37
Page 38
VMware vFabric Data Director Installation Guide
4Open the Admin View.
You perform the upgrade tasks in the Admin View.
If your site uses a proxy server to access the Web, see “Configure Proxy Settings,” on page 38. Otherwise, go
to “Download the Upgrade Source and Accept the EULA,” on page 38.
Configure Proxy Settings
If your site uses a proxy server to access the Web, configure the vSphere Update Manager to use the proxy
server. You need access to upgrade your Data Director virtual appliance.
Prerequisites
Obtain the values for the proxy server URL and port.
Procedure
1Click the Configuration tab.
2In the Proxy Settings section, click Use proxy.
3Enter appropriate values for the proxy URL and port.
4Click Test Connection to ensure that the settings are correct.
5Click Apply.
vSphere Update Manager can access the Web using your site's proxy server.
Download the Upgrade Source and Accept the EULA
To start the Data Director upgrade process, download the upgrade source from the URL supplied to you, either
in an email notification or by your VMware representative, and accept the EULA.
Prerequisites
You have the URL from which to download the upgrade source.
Procedure
1Log in to vSphere Client as an administrator.
2In the Download Settings tab, click Add Download Source.
3Enter the upgrade source URL in the Source URL text box.
4Click Validate URL to verify connectivity to the upgrade URL.
5Click OK to add the download source to VUM.
6Click Apply.
7Click Download Now.
8In the VA Upgrades tab, select the upgrade.
9Click EULA to accept the end user license agreement.
The Upgrade source is downloaded.
38 VMware, Inc.
Page 39
Chapter 5 vFabric Data Director Upgrade
Create an Upgrade Baseline
You upgrade virtual appliances by using a predefined virtual appliance upgrade baseline, or by creating a
custom virtual appliance upgrade baseline. Data Director virtual appliance upgrades require that you create
a custom virtual appliance upgrade baseline.
Prerequisites
You are logged in to vSphere Client as an administrator.
Verify that the vSphere Client is connected to a vCenter Server system with which vSphere Update Manager
is registered.
Procedure
1In the Baselines and Groups tab, click VMs/VAs to review the existing baselines and groups.
2Click Create. to start the New Baseline wizard.
3Enter a meaningful name, such as Data Director VA Upgrade 1.5, and click Next.
4Click Add Multiple Rules to create a set of rules that determine the target upgrade version for virtual
appliances.
5Review the baseline settings and click Finish.
Specify Upgrade Compliance Settings
Upgrade compliance settings ensure that the upgrade baseline does not conflict with the current state of your
Data Director virtual appliance.
Prerequisites
You are logged in to vSphere Client as an administrator.
Verify that vSphere Client is connected to a vCenter Server system with which vSphere Update Manager is
registered.
Procedure
1In vSphere Client, select Inventory > VMs and Templates, then click Upgrade Manager.
2Open the Compliance View and select the virtual appliance to upgrade.
3ClickAttach.
4Select the upgrade baseline.
5Click Attach.
6Verify that the virtual appliance needs to be updated.
aIn the inventory list in the left pane, right-click the baseline.
bSelect Scan for Updates.
VUM scans the baseline against the virtual appliance and determines whether the virtual appliance is up-todate with the latest Data Director version. A VUM scan result of 100% means that your Data Director version
is up to date.
What to do next
If the Data Director virtual appliance is up to date, discontinue the upgrade process. If the Data Director virtual
appliance is not up-to-date, go to “Shut Down Data Director,” on page 40 to continue the upgrade process.
VMware, Inc. 39
Page 40
VMware vFabric Data Director Installation Guide
Shut Down Data Director
Certain administrative tasks require that you shut down Data Director. These tasks include applying upgrades
and patches. Data Director system administrators shut down Data Director using the Data Director Web UI.
Prerequisites
You are logged in to the Data Director Web administration UI as a system administrator.
Procedure
1In the Administration tab, open the Version page.
2Click Shut Down Data Director.
Data Director shuts down and a prompt appears instructing you to wait. Wait for a few minutes before
continuing.
Configure the Upgrade Remediation Task and Run the Upgrade Process
The upgrade remediation task is the process by which vSphere Update Manager applies patches, extensions,
and upgrades to the Data Director virtual appliance. Configure and run the remediation task to complete the
Data Director virtual appliance upgrade process.
Prerequisites
You are logged in to vSphere Client as an administrator.
Verify that vSphere Client is connected to a vCenter Server system with which vSphere Update Manager is
registered.
Procedure
1In the left pane of the VMs and Templates view, right-click the virtual appliance to upgrade and select
Remediate.
2Select the upgrade baseline to apply and click Next.
3Run the virtual appliance upgrade remediation task.
The upgrade can take a few hours to complete.
4Type a unique name and an optional description for the task.
5Select Immediately to begin the upgrade process immediately after you complete the wizard and click
Next.
6Configure the rollback option, name the snapshot backup to roll back to, and click Next.
7Review the task definition and click Finish.
Data Director restarts when the upgrade remediation task completes.
What to do next
If upgrade does not succeed, revert both of the Data Director virtual appliance's virtual machines to the
snapshot that you took and reboot the virtual appliance. Resolve the blocking issue, for example, insufficient
resources, and restart the upgrade process with the remediation task configuration step. Step 3?
40 VMware, Inc.
Page 41
Chapter 5 vFabric Data Director Upgrade
Upgrade Data Director Database Virtual Machines (DBVMs)
Data Director system administrators upgrade Database Virtual Machines from the Data Director Web UI.
Prerequisites
Verify that Data Director is deployed and running.
Verify that the Data Director virtual appliance was upgraded and an updated database configuration template
is available. See “Upgrade a Data Director Virtual Appliance,” on page 36.
Make backups of the databases that you plan to upgrade.
Procedure
1Log in to the Data Director Web UI as a system administrator.
2In the Administration tab, publish the new database template.
aIn the left pane, expand Templates and select Database Configuration Templates.
bIn the DB Configuration Templates pane, right-click the new database template and select Publish.
Data Director publishes the updated template.
cPerform the same steps to publish new Backup Configuration templates.
3In each organization tab, right-click a database and select Upgrade.
4Select the Upgrade to latest version check box, and specify the start time.
The Tasks pane shows the upgrade task progress.
When the upgrade completes, use the DBVM as usual.
VMware, Inc. 41
Page 42
VMware vFabric Data Director Installation Guide
42 VMware, Inc.
Page 43
Index
A
accepting license agreement 30
accounts, system administrator 31
Admission Control 11
audience for Data Director 5
Data Director deployment 26
Data Director virtual appliance 35
DB Access Network 17
DB Name Server 33
DB Name Service Network 33
dbvm upgrade 41
DBVM upgrade process overview 36
deploy, prerequisites 25
deploy OVA package 25
finish deploying Data Director 27
firewall ports for network traffic 18
firewalls 17
four VLAN example 20
FQDN 30
H
Host Isolation Response 11
Host Monitoring Status 11
I
installation prerequisites 9
Internal Network 17, 33
IP address and DHCP setup 20
IP allocation 17
VMware, Inc.
R
remediation
defined 35
VUM 35
remediation task, define 36
review setup 34
S
self-service database lifecycle management 5
setting up branding 32
setup wizard, start 30
shut down Data Director 40
SMTP 32
start vSphere Update Manager 37
supported number of vCPUs 9
system administrator account 31
U
Update Manager 17
updated information 7
43
Page 44
VMware vFabric Data Director Installation Guide
upgrade a virtual appliance 36
upgrade baseline, creating 39
upgrade compliance settings 39
upgrade Data Director database virtual machines
process overview 36
upgrade Data Director virtual appliance process
overview 36
upgrade dbvm 41
upgrade process for vFabric Data Director 35
upgrade remediation task, configuring 40
upgrade source, downloading 38
upgrade vFabric Data Director 35
URL for Data Director 30
user management mode 31
V
vApp 25
vCenter Network, configuring 32
vFabric Data Director
upgrade 35
upgrade process 35
virtual appliance, Data Director 35
virtual switches 13
VM Restart Priority 11
vSphere DRS 11
vSphere HA
admission control 11
Host Monitoring Status 11
vSphere settings 11
vSphere setup 9
vSphere Update Manager 17
VUM remediation 35
W
Web Console Network 17, 26
44 VMware, Inc.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.