50PF(R)...(W) Series
Vishay High Power Products
|
|
|
|
|
Standard Recovery Diodes, |
|
|
||||||
|
Generation 2 DO-5 (Stud Version), 50 A |
|
|
||||||||||
50PF(R)... |
|
50PF(R)...W |
FEATURES |
|
|
||||||||
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
• High surge current capability |
|
|
|||
|
|
|
|
|
|
|
|
• Designed for a wide range of applications |
RoHS |
||||
|
|
|
|
|
|
|
|
COMPLIANT |
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
• Stud cathode and stud anode version |
|
|
|||
|
|
|
|
|
|
|
|
• Wire version available |
|
|
|||
|
|
|
|
|
|
|
|
• Low thermal resistance |
|
|
|||
|
|
|
|
|
|
|
|
• UL approval pending |
|
|
|||
DO-203AB (DO-5) |
DO-203AB (DO-5) |
• RoHS compliant |
|
|
|||||||||
|
|
|
|
|
|
|
|
• Designed and qualified for multiple level |
|
||||
|
|
|
|
|
|
|
|
TYPICAL APPLICATIONS |
|
|
|||
|
|
|
|
|
|
|
|
• Battery charges |
|
|
|||
PRODUCT SUMMARY |
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
||||
IF(AV) |
|
|
|
|
50 A |
|
|
• Converters |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
• Power supplies |
|
|
|||
|
|
|
|
|
|
|
|
• Machine tool controls |
|
|
|||
|
|
|
|
|
|
|
|
• Welding |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|||
MAJOR RATINGS AND CHARACTERISTICS |
|
|
|
|
|
|
|||||||
PARAMETER |
|
|
|
|
TEST CONDITIONS |
|
|
VALUES |
|
|
UNITS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IF(AV) |
|
|
|
|
|
|
|
50 |
|
|
A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TC |
|
140 |
|
|
°C |
|
||||
|
|
|
|
|
|
|
|
||||||
IF(RMS) |
|
|
|
|
|
|
|
78 |
|
|
A |
|
|
IFSM |
|
|
|
50 Hz |
|
800 |
|
|
A |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
60 Hz |
|
830 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
I2t |
|
|
|
50 Hz |
|
3200 |
|
|
A2s |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
60 Hz |
|
2900 |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VRRM |
|
|
|
Range |
|
|
400 to 1200 |
|
|
V |
|
||
TJ |
|
|
|
|
|
|
|
|
- 55 to 180 |
|
|
°C |
|
ELECTRICAL SPECIFICATIONS |
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VOLTAGE RATINGS |
|
|
|
|
|
|
|
|
|
|
|||
|
VOLTAGE |
|
VRRM, MAXIMUM REPETITIVE |
|
VRSM, MAXIMUM NON-REPETITIVE |
|
IRRM MAXIMUM |
||||||
TYPE NUMBER |
|
PEAK REVERSE VOLTAGE |
|
PEAK REVERSE VOLTAGE |
|
AT TJ = 150 °C |
|||||||
CODE |
|
|
|
||||||||||
|
|
V |
|
V |
|
mA |
|
||||||
|
|
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
40 |
|
|
|
400 |
|
|
|
500 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
50PF(R)...(W) |
80 |
|
|
|
800 |
|
|
|
960 |
|
|
9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
120 |
|
|
|
1200 |
|
|
|
1440 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Document Number: 93516 |
For technical questions, contact: ind-modules@vishay.com |
www.vishay.com |
Revision: 01-Oct-08 |
|
1 |
50PF(R)...(W) Series
Vishay High Power Products |
Standard Recovery Diodes, |
|
|
|
||||
|
|
Generation 2 DO-5 (Stud Version), 50 A |
|
|||||
|
|
|
|
|
|
|
|
|
FORWARD CONDUCTION |
|
|
|
|
|
|
|
|
PARAMETER |
SYMBOL |
|
|
TEST CONDITIONS |
VALUES |
UNITS |
||
|
|
|
|
|
|
|
|
|
Maximum average forward current |
IF(AV) |
180° conduction, half sine wave |
50 |
|
A |
|||
at case temperature |
140 |
|
°C |
|||||
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
Maximum RMS forward current |
IF(RMS) |
|
|
|
|
78 |
|
A |
|
|
t = 10 ms |
|
No voltage |
|
800 |
|
|
Maximum peak, one-cycle forward, |
IFSM |
t = 8.3 ms |
|
reapplied |
|
830 |
|
A |
non-repetitive surge current |
t = 10 ms |
|
100 % VRRM |
|
670 |
|
||
|
|
|
|
|
||||
|
|
t = 8.3 ms |
|
reapplied |
Sinusoidal half wave, |
700 |
|
|
|
|
t = 10 ms |
|
No voltage |
initial TJ = 150 °C |
3200 |
|
|
|
|
|
|
reapplied |
|
|
|
|
Maximum I2t for fusing |
I2t |
t = 8.3 ms |
|
|
2900 |
|
A2s |
|
|
|
|
|
|
|
|||
t = 10 ms |
|
100 % VRRM |
|
2260 |
|
|||
|
|
|
|
|
|
|||
|
|
t = 8.3 ms |
|
reapplied |
|
2050 |
|
|
|
|
|
|
|
|
|
|
|
Maximum I2√t for fusing |
I2√t |
t = 0.1 to 10 ms, no voltage reapplied |
32 000 |
|
A2√s |
|||
Low level value of threshold voltage |
VF(TO) |
(16.7 % x π x IF(AV) < I < π x IF(AV)), TJ = TJ maximum |
0.77 |
|
V |
|||
Low level value of forward |
rf |
(16.7 % x π x IF(AV) < I < π x IF(AV)), TJ = TJ maximum |
4.30 |
|
mΩ |
|||
slope resistance |
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
Maximum forward voltage drop |
VFM |
Ipk = 125 A, TJ = 25 °C, tp = 400 µs rectangular wave |
1.40 |
|
V |
|||
|
|
|
|
|
|
|
||
THERMAL AND MECHANICAL SPECIFICATIONS |
|
|
|
|
||||
PARAMETER |
SYMBOL |
|
|
TEST CONDITIONS |
VALUES |
|
UNITS |
|
|
|
|
|
|
|
|
|
|
Maximum junction operating and |
TJ, TStg |
|
|
|
|
- 55 to 180 |
|
°C |
storage temperature range |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Maximum thermal resistance, |
RthJC |
DC operation |
|
|
0.51 |
|
|
|
junction to case |
|
|
|
|
||||
|
|
|
|
|
|
|
K/W |
|
|
|
|
|
|
|
|
|
|
Maximum thermal resistance, |
RthCS |
Mounting surface, smooth, flat and greased |
0.25 |
|
||||
|
|
|||||||
case to heatsink |
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
Tighting on nut (1) |
|
3.4 + 0 - 10 % |
|
|
||
Allowable mounting torque |
|
Not lubricated threads |
|
(30) |
|
N · m |
||
|
Tighting on Hexagon (2) |
|
2.3 + 0 - 10 % |
|
(lbf · in) |
|||
|
|
|
|
|||||
|
|
Lubricated threads |
|
(20) |
|
|
||
|
|
|
|
|
|
|
|
|
Approximate weight |
|
|
|
|
|
15.8 |
|
g |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.56 |
|
oz. |
|
|
|
|
|
|
|
|
||
|
|
|
|
|
||||
Case style |
|
See dimensions - link at the end of datasheet |
DO-203AB (DO-5) |
|||||
|
|
|
|
|
|
|
|
|
Notes
(1)As general recommendation we suggest to tight on Hexagon and not on nut
(2)Torque must be applicable only to Hexagon and not to plastic structure
www.vishay.com |
For technical questions, contact: ind-modules@vishay.com |
Document Number: 93516 |
2 |
|
Revision: 01-Oct-08 |
50PF(R)...(W) Series
|
Standard Recovery Diodes, |
Vishay High Power Products |
|||
|
Generation 2 DO-5 (Stud Version), 50 A |
|
|
|
|
|
|
|
|
|
|
RthJC CONDUCTION |
|
|
|
|
|
CONDUCTION ANGLE |
SINUSOIDAL CONDUCTION |
RECTANGULAR CONDUCTION |
TEST CONDITIONS |
UNITS |
|
|
|
|
|
|
|
180° |
0.11 |
0.10 |
|
|
|
|
|
|
|
|
|
120° |
0.16 |
0.16 |
|
|
|
|
|
|
|
TJ = TJ maximum |
|
90° |
0.20 |
0.22 |
|
K/W |
|
|
|
|
|
|
|
60° |
0.29 |
0.31 |
|
|
|
|
|
|
|
|
|
30° |
0.49 |
0.50 |
|
|
|
|
|
|
|
|
|
Note
• The table above shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC
<![endif]>Maximum Allowable Case Temperature (°C)
180 |
|
50PF(R) Serie |
|
|
||
|
|
|
|
|||
170 |
|
RthJC = 0.51 K/W |
|
|
||
|
|
|
|
|
|
|
160 |
|
|
|
|
|
|
150 |
|
|
|
Conduction Angle |
|
|
|
|
|
|
|
|
|
140 |
|
|
|
|
180° |
|
|
|
|
|
120° |
|
|
130 |
|
|
|
|
|
|
|
|
|
90° |
|
|
|
|
|
|
|
|
|
|
120 |
|
30° |
60° |
|
|
|
|
|
|
|
|
||
110 |
10 |
20 |
30 |
40 |
50 |
60 |
0 |
Average Forward Current (A)
Fig. 1 - Current Ratings Characteristics
<![endif]>Maximum Allowable Case Temperature (°C)
180 |
50PF(R) Series |
|
|
170 |
RthJC (DC) = 0.51 K/W |
|
|
160 |
Conduction Period |
|
|
150 |
30° |
|
|
140 |
60° |
|
|
130 |
90° |
120° |
|
|
180° DC |
120
0 10 20 30 40 50 60 70 80
Average Forward Current (A)
Fig. 2 - Current Ratings Characteristics
<![if ! IE]> <![endif]>(W) |
100 |
180° |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<![if ! IE]> <![endif]>Loss |
|
|
|
|
|
|
|
|
|
|
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
120° |
|
|
|
|
|
|
|
|
1 |
. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
|
|
|
|
|||
80 |
|
|
|
|
|
1 |
|
K/W |
K/W |
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
<![if ! IE]> <![endif]>Power |
90° |
|
|
|
|
|
. |
|
|
|
|
|
|
|||
|
|
|
|
|
|
5 |
|
|
|
|
|
|
||||
|
60° |
|
|
|
|
|
|
|
K/W |
|
|
|
|
|
||
|
|
|
|
|
|
2 |
|
|
|
|
|
|
||||
<![if ! IE]> <![endif]>Forward |
60 |
30° |
|
|
|
|
|
|
|
K/W |
|
|
|
|
|
|
|
RMS Limit |
|
|
|
|
3 |
K/W |
|
|
|
|
|
||||
40 |
|
|
|
|
|
|
|
|
|
|
|
|||||
<![if ! IE]> <![endif]>Allowable |
|
|
|
|
5 |
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
K/W |
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
Conduction Angle |
7 |
|
|
|
|
|
|
|
||||
20 |
|
|
|
K/W |
|
|
|
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
10 |
|
|
|
|
|
|
|
|||
<![if ! IE]> <![endif]>Maximum |
|
|
|
50PF(R) Series |
|
K/W |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
||||||
0 |
|
|
Tj |
= 180°C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
60 |
|
|
30 |
60 |
90 |
120 |
150 |
180 |
|||
0 |
10 |
20 |
30 |
40 |
50 |
|
|
Average Forward Current (A) Maximum Allowable Ambient Temperature (°C)
Fig. 3 - Forward Power Loss Characteristics
Document Number: 93516 |
For technical questions, contact: ind-modules@vishay.com |
www.vishay.com |
Revision: 01-Oct-08 |
|
3 |