1. Prepare cabinet opening as shown in Figures 1, 2A, 2B, 2C.
|
B |
|
|
A |
|
|
|
|
|
|
|
|
|
|
|
C |
|
|
|
|
D |
E |
|
|
|
|
|
|
|
|
G |
|
F |
|
|
|
|
|
H |
|
|
|
|
|
|
|
|
I |
|
K |
|
Note: the face of the shelf must |
|
|
|
sit 1 |
3/4" (44.45 mm) back from |
||
|
|
|
|
||
L |
|
|
J |
M |
the face of the cabinet. |
|
|
|
|
|
|
|
|
|
|
N |
|
|
|
|
|
shelf face O |
|
|
|
|
|
|
cabinet face |
Figure 1
Parts Included
Qty.
PREF-B019MRP0 Flush Mount
1
2
LX-CZB055MRE0
Mounting screws
A.6" (152.40 mm)
B.Suggested electrical outlet location
C.Anti-Tip block
D.5" (127 mm)
E.3-1/2" (88.90 mm)
F.4" (101.60 mm)
G.24-3/16" (614.35 mm) minimum
24-1/2" (622.3 mm) maximum
H.14-13/16" (376.24 mm) to bottom of Anti-Tip block
I.1-1/16" (26.97 mm)
J.23-1/2" (596.90 mm) minimum depth
K.22-1/8" (561.97 mm)
L.1-3/4" (44.45 mm)
M.16-7/8" (428.62 mm) opening
N.Floor must support 100 lb (45.4 kg)
O.1-3/4" (44.45 mm)
|
Anti-Tip block |
|
A |
Figure 2A |
CL |
Topview |
Mounting cleat |
Drawer face |
B |
C |
Cabinet |
face |
|
No oven |
Suggested electrical |
A |
|
|
outlet location |
Anti-Tip block |
|
B |
|
C |
Figure 2B |
Front view |
A.22" (558.8 mm) mounting cleat opening width
B.1/4" (6.35 mm)
C.1-1/16" (26.97 mm)
A.22-1/8" (561.97 mm) mounting cleat opening width
B.24-3/16" (614.35 mm) minimum
24-1/2" (622.3 mm) maximum flush opening width
C.3/4" (19.05 mm) shelf
2
Move oven location downward for extended countertops for better viewing angle.
16 7/8 "
(428.62 mm) flush opening height
Front face of cabinet
3/4" (19.05 mm) shelf
13/4" (44.45 mm) front face of shelf
Anti-Tip
block
Figure 2C
Side view
2. Install deflector
Shelf detail showing the deflector vent during installation.
Position deflector vent and mark holes. Pre drill using a1/16" (1.57 mm) bit before mounting.
Figure 3A
3.Place the drawer adjacent to the wall or cabinet opening. Plug the power supply cord into the electrical outlet.
4.Carefully guide the drawer into the prepared opening. Avoid contact with the sides of the cutout opening and also pinching the cord between the oven and the wall.
5.Slide the drawer all the way back until the mounting flanges touch the cleats mounted in the cabinet opening.
6.Open the drawer. Using the 4 holes on the drawer as a template, pre drill the cabinet using a 1/16” (1.57 mm) bit. See Figure 4.
7.Secure the drawer with the 4 screws supplied.
Shelf detail showing the deflector vent installed.