Built-In 30”W. Electric Smoker O ven & 26”W. Gas Oven
Standard Features & Accessories
Both models include
• Commercial-type construction, design,
and styling
o Built from thick sheets of rugged,
non-rusting stainless steel
• Agency-certified for outdoor use
• Three heavy-duty racks
VEOS model includes
• Standard capacity—3.2 cu. ft. (90.6 lit.)
o 23”W. (58.4 cm) x 14-7/8”H. (37.8
cm) x 15-15/16”D. (40.5 cm)
o Can accommodate up to 40 lbs. of
meat
o Large capacity water pan holds 1.5
gallons (5.7 liters) of water for
smoking
o Drip tray can accommodate 1.5
gallons (5.7 liters) of liquid
o Smoker box is capable of holding
large quantities of wood chips or
chunks of wood for smoking
• Exclusive—state-of-the-art plenum
system mixes heat, water vapor, and
smoke for perfect cooking
environment
• Baking temperatures from 175°F to
400°F (80°C to 205°C)
• Separate control for smoke element
• 120-volt, thermal convection oven
• Precision louvered oven side walls for
balanced oven heat
• Six rack positions
• Cook with smoke, water vapor, and
heat—meats are tenderized by slow
cooking with heat and moisture,
resulting in less shrinkage and perfect
texture
o Roasting—slow cook prime rib or any
other roast to perfection using
regular oven
o Hot and cold smoking—imparts
deep smoke flavor to meats, fish,
cheeses, vegetables, and more
o Moist vegetable cooking—gentle
moist cooking to retain minerals and
color in vegetables. No steaming
under pressure or harsh boiling
o Baking—thermal convection oven
can be used for baking everything
from side dishes to desserts
VGSO model includes
• Standard capacity—2.5 cu. ft. (70.8
lit.)—18-1/8”W. (46.0 cm) x 12-1/2”H.
(31.8 cm) x 18-3/4”D. (47.6 cm)
• 20,000 BTU gas oven
• 200 – 550ºF (93º – 260ºC) thermostat
• Natural airflow bake function, perfect
OUTDOOR—COOKING
for baking side dishes and desserts to
complement items cooked on the grill
• Electronic ignition powered by 9-volt
battery
• Four rack positions
o Must be factory ordered for use with
LP/propane gas (L) or natural gas (N)
o LP/propane gas model equipped
with high-capacity hose/regulator
assembly
o To convert oven from natural to
LP/propane, or LP/propane to gas,
you must use a Viking conversion kit
(see Installation Notes &
Accessories)
Model Options
FINISH DETAILS
• Stainless Steel (SS)
• Brass Trim Option (BR)—nameplate,
handle/brackets, and knob bezel(s).
Brass components have a durable
protective coating for maintenance-free
normal use.
VEOS100T
30”W. Electric
Smoker Oven
VGSO260T
26”W. Gas Oven
ORDERING INSTRUCTIONS
For gas oven, you must specify fuel type (“N” or “L”) following model number (VGSO260TNSS).
If ordering optional brass trim, specify code at end (VGSO260TNSSBR).
P L A N NI N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M•1 - 8 8 8 - V I K I N G 1
To edge of door25-1/2” (64.8 cm)25-1/4” (64.1 cm)
To front of handle28-3/32” (71.4 cm)27-3/4” (70.5 cm)
With door open53-19/32” (136.1 cm)38-3/4” (98.4 cm)
Note: The use of cabinets for storage above the oven may result in a potential burn hazard. Combustible items may ignite, and
metallic items may become hot and cause burns. If cabinet storage is to be provided, the risk can be reduced by installing a hood
that projects horizontally a minimum of 5” (12.7 cm) beyond the bottom of the cabinets.
Do not obstruct the flow of combustion and ventilation air.
Cutout width28-1/2” (72.4 cm)23-7/8” (60.6 cm) min. to 24-1/4” (61.6 cm) max.
Cutout height28-3/16” (71.6 cm)24-3/8” (61.9 cm) min. to 24-3/4” (62.9 cm) max.
From floor4-3/4” (12.1 cm) min.*17” (43.2 cm)
Cutout depth24-1/2” (62.2 cm)23-3/4” (60.3 cm)
*Undercounter installation for VEOS only
**Recommended, for wall installation
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M•1 - 8 8 8 - V I K I N G 1
Built-In 30”W. Electric Smoker Oven & 26”W. Gas Oven
Installation Requirements
OUTDOOR—COOKING
30”W. Electric
GAS (VGSO)
Bake burner rating
• Two burners, each 20,000 BTU
(5.9 kW) Nat./LP
• Can field convert to
LP/propane (see Installation
Notes & Accessories for kit)
• Fixed piping installations
o Check with local gas utility
company or with local codes
for instructions on installing
gas supply lines. All gas
connections should be made
by a competent technician
and in accordance with local
codes and or ordinances. In
the absence of codes, the
installation must comply with
the National Fuel Gas Code
ANSI Z223.1.
o An installer-supplied gas
shut-off valve must be
installed in an easily
accessible location. All
installer-supplied parts must
conform to local codes.
o Must be isolated from the
gas supply piping system by
closing its individual manual
shut-off valve during any
pressure testing of that
system at test pressures
equal to or less than
1/2 psi (3.5 kPa).
Natural gas models
• Water column pressure
o Operating pressure—4.0”
WCP
o Supply pressure of 6” – 14”
WCP
VEOS100T
Smoker Oven
26”W. Gas Oven
UTILITY
REQUIREMENTS
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
• Accepts standard residential
1/2” (1.3 cm) ID gas service
line;
1/2” (1.3 cm) NPT male with
7/8” (2.2 cm) flare adapter.
o If using a Viking GSH12
flexible hose, remove the
1/2” (1.3 cm) flare adapter
and attach hose to the
7/8” (2.2 cm) male flare on
the regulator assembly.
LP/propane models
• Water column pressure
o Operating pressure—10”
WCP
o Supply pressure of 11” – 14”
WCP (for fixed piping
installations)
o If incoming pressure exceeds
14” WCP, a step-down
regulator is required.
• Accepts standard residential
1/2” (1.3 cm) ID gas service
line; 1/2” (1.3 cm) NPT male
with 3/8" (0.95) flare adapter.
LP/propane tank installations
• Water column pressure
o Operating pressure—10”
WCP
• Includes high-capacity
hose/regulator assembly for
connection to a standard
5-gal./20-lb. (approx.
12” diameter/18"H.)
LP/propane gas cylinder
equipped with a Type 1, QCC1 connector
VGSO260T
o The cylinder connection
device must be compatible
with the Type 1, QCC-1
connector on the outdoor
o The cylinder must be
provided with a shut-off
valve terminating in an
LP/propane gas supply
cylinder valve outlet
specified.
o The cylinder supply system
must be arranged for vapor
withdrawal and provided
with a listed OPD (overfilling
prevention device).
ELECTRICAL
Smoker element rating
• One element 300 watts (2.7
amps)
Cook element rating
• Two (elements, each 750 watts
(6.8 amps)
• VEOS
o 120V/60 Hz, 30-amp
o 4’ (121.9 cm) 3-wire cord
with grounded 3-prong plug
o Max. amp usage—17.7
(1,950 watts)
• VGSO
o 9-volt battery for ignition
PLUMBING
Not applicable
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M•1 - 8 8 8 - V I K I N G 1