IMPORTANT–Please Read and Follow!
NOTE:
If installing hood with warming shelf panel,
install warming shelf panel first.
IMPORTANT – PLEASE READ AND FOLLOW
• Before beginning, please read these instructions
completely and carefully.
• Do not remove permanently affixed labels, war nings, or
plates from the product. This may void the warranty.
• Please observe all local and national codes and
ordinances. If no local codes are applicable, wire in
accordance with the National Electrical Code,
ANSI/NFPA 70-latest edition.
• Damp environment approved models should be installed
in a covered non-enclosed area and should be protected
from the elements as much as possible.
• The installer should leave these instructions with the
consumer who should retain for local inspector’s use and
for future reference.
• Check with a qualified and trained installer or local codes
for makeup air requirement, if any.
This hood is for residential installation only and is not
designed for installation over a commercial product. Make
sure power is off at the main circuit breaker or fuse box
before making connections. To avoid risk of fire, electric
shock, or injury to persons, turn off the electricity to the
hood from the power supply before servicing or cleaning.
Viking hoods are equipped with variable speed control
blowers. These units will not function with a single speed
ventilator. All Viking Range ventilator kits are designed
specifically for use with Viking Range hoods. Use of any
non-Viking Range ventilator kit will void the hood warranty.
Viking hoods are equipped with the variable speed
controls for blowers. These units will not function with a
single speed ventilator. All Viking ventilator kits are
designed specifically for use with Viking hoods. Use of any
non-Viking ventilator kit will void the hood warranty.
READ AND SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Installation work and electrical wiring must be
done by qualified person(s) in accordance with
all applicable codes and standards, including
fire-rated construction.
2. Sufficient air is needed for proper combustion
and exhausting of gases through the flute
(chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the
American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the
local code authorities.
3. When cutting of drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
4. Ducted fans must alwaysbe ventedto theoutdoors.
5. WARNING!: To reduce risk of fire, use only
metal ductwork
6. CAUTION!: To reduce risk of fire and to
properly exhaust air, be sure to duct air outside.
Do not vent exhaust air into spaces within walls
or ceilings, or into attics, crawl spaces, or
garages.
7. CAUTION!: To Reduce the Risk of Fire and
Electric Shock, Install this rangehood only with
remote blower models manufactured by Viking,
model numbers – DEV900/DEV1200,
VEV900/VEV1200, OR DEV1500, VEV1500 or
integral blowers manufactured by Viking, model
numbers – DIV300, DIV440, DIV600, DIV800,
DIV1200, VIV300, VIV600, or VIV1200. NOTE –
Please refer inside for specific canopy/blower
combinations.
W A R N I N G
W A R N I N G
To reduce the risk of fire, electric shock, or injury
to persons, observe the following:
• Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
• Before servicing or cleaning unit, switch power off
at service panel and lock service panel to prevent
power from being switched on accidentally. When
the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such
as a tag, to the service panel.
2
Warnings & Important Information
________________________________________________________ 3-
4
VWH 10”H. Wall Hoods w/Standard Ventilator 24”, 30”, & 36”
Dimensions & Specifications _____________________________________________________ 5
Clearance Dimensions ___________________________________________________________ 6
Interior Ventilator Dimensions ____________________________________________________ 7
VWH 18”H. 24”/27” Deep Wall Hoods 24”, 30”, 36”, 42”, 48”, 54”, 60”, & 66”
Dimensions & Specifications ______________________________________________________ 8
Clearance Dimensions _____________________________________________________________9
Interior Ventilator Dimensions _____________________________________________________ 10
Exterior Ventilator Dimensions ___________________________________________________ 11
VWH 18”H. T-Series Wall Hoods 36”, 48”, & 60”
Dimensions & Specifications _____________________________________________________ 12
Clearance Dimensions __________________________________________________________ 13
VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, 60”, & 66”
Dimensions & Specifications _____________________________________________________ 14
Clearance Dimensions __________________________________________________________ 15
Interior Ventilator Dimensions ___________________________________________________ 16
Exterior Ventilator Dimensions ___________________________________________________ 17
VIH Island Hoods 36”, 42”, 54”, & 66”
Dimensions & Specifications _____________________________________________________ 18
Clearance Dimensions___________________________________________________________ 19
Interior Ventilator Dimensions ___________________________________________________ 20
Exterior Ventilator Dimensions ___________________________________________________ 21
VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”
Dimensions & Specifications _____________________________________________________ 22
Clearance Dimensions___________________________________________________________ 23
Interior Ventilator Dimensions ___________________________________________________ 24
Exterior Ventilator Dimensions ___________________________________________________ 25
VBCV Wall Custom Ventilator System
Dimensions & Specifications _____________________________________________________ 26
Installing Hood Canopy _________________________________________________________ 27
Clearance Dimensions___________________________________________________________ 28
VBCV Ventilator Dimensions _____________________________________________________ 29
VICV Island Custom Ventilator System
Dimensions & Specifications _____________________________________________________ 31
Installing Hood Canopy _________________________________________________________ 32
Clearance Dimensions___________________________________________________________ 33
VICV Ventilator Dimensions ______________________________________________________ 34
Planning Information________________________________________________________________ 36
Installation Procedures
Installation (VWH 10”H. Wall Hoods w/Standard Ventilator) __________________________ 37
Duct Cover Option (VWH 10”H. Wall Hoods w/Standard Ventilator)___________________ 39
Installation (VWH 10”H. Wall Hoods w/Recirculating Kit) _____________________________39
Installation (VWH 18”H. Wall & VCWH Chimney Wall Hoods) ________________________ 42
Duct Cover Option (VWH 18”H. Wall Hoods)_______________________________________ 43
Duct Cover Option (VCWH Chimney Wall Hoods) __________________________________ 44
Installation (VIH/VCIH Island Hoods) ______________________________________________ 45
Service & Registration_______________________________________________________________ 47