•Please read all instructions thoroughly before installing the Convection Microwave Hood. Two people are
recommended to install this product.
•If a new electrical outlet is required, its installation should be completed by a qualified electrician before
the Convection Microwave Hood is installed. See ELECTRICAL GROUNDING INSTRUCTIONS on page 2.
Mounting Space
This Convection Microwave Hood requires a mounting
space on a wall as shown in figure 1. It is designed to
be used with standard 12-inch wall cabinets.
For proper installation and servicing, a 2-inch space is
necessary between the top of the range backguard and
the bottom of the Convection Microwave Hood.
1
12"
30"
15.5"
Backguard
At least 2"
36" or more
from cooking
surface
72" or more
from floor
Wall Construction
This Convection Microwave Hood should be mounted
against and supported by a flat vertical wall. The wall
must be flat for proper installation. If the wall is not flat,
use spacers to fill in the gaps. Wall construction should
be a minimum of 2" x 4" wood studding and 3/8" or more
thick dry wall or plaster/lath. The mounting surfaces must
be capable of supporting a weight of 110 pounds—the
oven and contents—AND the weight of all items which
would normally be stored in the top cabinet above the
unit.
The unit should be attached to a minimum of one 2" x
4" wall stud or two 2" x 3" wall studs.
To find the location of the studs, one of the following
methods may be used:
•Use a stud finder, a magnetic device which locates the
nails in the stud.
•Use a hammer to tap lightly across the mounting
surface to find a solid sound. This will indicate stud
location.
The center of the stud can be located by probing the
wall with a small nail to find the edges of the stud and
then placing a mark halfway between the edges. The
center of any adjacent studs will normally be 16" or 24"
to either side of this mark.
E1
Electrical Grounding
Instructions
This appliance must be grounded. This oven is equipped
with a cord having a grounding wire with a grounding
plug. It must be plugged into a wall receptacle that is
properly installed and grounded in accordance with the
National Electrical Code and local codes and ordinances.
In the event of an electrical short circuit, grounding
reduces risk of electric shock by providing an escape
wire for the electric current.
WARNING: Improper use of the grounding plug can
result in a risk of electric shock.
Electrical Requirements
The oven is equipped with a 3-prong grounding plug.
DO NOT UNDER ANY CIRCUMSTANCES CUT OR
REMOVE THE GROUNDING PIN FROM THE PLUG.
DO NOT USE AN EXTENSION CORD. If the power
supply cord is too short, have a qualified electrician or
serviceman install an outlet near the appliance.
The Power Supply Cord and plug must be connected to
a separate 120 Volt AC, 60 Hz, 15 Amp, or more branch
circuit, single grounded receptacle. The receptacle
should be located inside the cabinet directly above
the Convection Microwave Hood mounting location as
shown in figure 2.
NOTE:
•If you have any questions about the grounding or
electrical instructions, consult a qualified electrician
or serviceperson.
Hood Exhaust Duct
When the hood is vented to the outside, a hood exhaust
duct is required. All ductwork must be metal; absolutely
do not use plastic duct. Check that all connections are
made securely. Please read the following carefully:
EXHAUST CONNECTION: The hood exhaust has been
designed to connect to a standard 3 ¼" X 10" rectangular
duct. If round duct is required, a rectangular-to-round
adapter must be used.
REAR EXHAUST: If a rear or horizontal exhaust is to be
used, care should be taken to align the exhaust with the
space between the studs, or wall should be prepared
at the time it is constructed by leaving enough space
between wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air
movement, the total duct length of 3 ¼" X 10" rectangular
or 6" diameter round duct should not exceed 140 feet.
Elbows, adapters, wall caps, roof caps, etc. present
additional resistance to air flow and are equivalent to a
section of straight duct which is longer than their actual
physical size. When calculating the total length, add
the equivalent lengths of all transitions and adapters
plus the length of all straight duct sections. Figure 3
shows the approximate feet of equivalent length of some
typical ductwork parts. Use the values in parentheses for
calculating air flow resistance equivalent, which should
total less than 140 feet.
•Neither Viking Range, LLC nor the dealer can accept
any liability for damage to the oven or personal injury
resulting from failure to observe the correct electrical
connection procedures.
Ground
Receptacle
figure
figure
Opening for
Power Cord
E2
figure
figure
Tools Recommended
for Installation
•Phillips Screwdriver
•Electric Drill
•1/2", 5/8" and 3/32" Drill Bits
•1½" Wood Bit or Metal Hole Cutter
(if metal cabinet is used)
Installation Hardware
The INSTALLATION HARDWARE (items 1 - 7) packed
with the oven should contain the following:
ItemPart Name & CodeQuantity
Wood Screw 5 X 35 mm
1
XTSS750P35000
Toggle Bolt 3/6 inch
2
LX-BZ0195WRE0
Top Cabinet Screw 5 X 60 mm
3
XBRS750P60000
Flat Washer 30 mm diameter
4
XWHS750 -16300
Grommet LBSHC0040MRE0
5
Tapping Screw 4 x 12 mm
6
XOTS740P12000
Exhaust Damper Assembly
7
FF TA-B004MRK0
6
4
2
2
1
4
1
•Saw to cut exhaust opening (if needed)
•Protective Drop Cloth for product and range -
you may also use carton for protection
•Scissors•Measure
•Pencil•Tape
Parts Included
Hardware Kit #5450M023-60
Use with metal cabinets.
Surround the power cord
opening. Cut to fit.
figure
figure
Parts shown not to common scale.
Basic Specifications
Microwave Oven
DescriptionVMOR205, CVMOR205, RDMOR206, RVMHC330
Overall Width29-15/16"(76.0 cm)
Overall Height from Bottom16 -11/32"(41.5 cm)
Overall Depth from Rear15-9/32"(38.8 cm)
Width17-1/8"(43.5 cm)Depth13-13/16" ( 35.1 cm)
Height8-1/16"(20.5 cm)Overall1.1 cu. ft.
E3
Ventilation System (Preparing Oven for Installation)
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
This Convection Microwave Hood is designed for
adaptation to three types of hood ventilation systems.
Select the type required for your installation.
Hood Fan
Unit
RECIRCULATING — non-vented, ductless.
Follow installation procedure (A). Recirculating requires
the use of the Charcoal Filter, which has been installed
in the oven.
•The unit is shipped assembled for recirculating.
•The Exhaust Damper Assembly is NOT REQUIRED for
recirculating exhaust.
•Charcoal Filter, included with the unit, IS REQUIRED
for recirculating exhaust.
figure
figure
HORIZONTAL EXHAUST: Withdraw hood fan unit
carefully and slip wires out of wire box.
Hood Fan
Unit
figure
figure
(B) Horizontal Exhaust: Outside
Ventilation
Fan Cover
Bracket
figure
figure
HORIZONTAL EXHAUST: Remove and save 4 screws.
Remove fan cover bracket.
HORIZONTAL EXHAUST: Rotate hood fan unit 180˚ so
that exhaust ports are facing rear of oven unit.
• CAUTION: Do not pull or stretch hood fan wiring.
•Replace hood fan unit into the oven unit. Be careful
not to pinch the lead wire between the inner bracket
and the hood fan unit.
•Put the lead wire into wire box.
E4
Ventilation System (Preparing Oven for Installation)
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
Fan Cover
Bracket
figure
figure
(C) Vertical Exhaust: Outside
Ventilation
• Remove and save 4 screws and fan cover bracket as shown
in figure 5. Withdraw hood fan unit. See figure 6.
figure
figure
(A) Rotate 90˚
HORIZONTAL EXHAUST: Replace the fan cover bracket.
Make sure the fan blades are visible through the rear
openings in the oven before proceeding. Attach fan cover
bracket to unit with 4 screws. The hood fan unit is now
rotated for horizontal exhaust operation.
Exhaust Damper
Assembly
figure
figure
HORIZONTAL EXHAUST: Attach the Exhaust Damper
Assembly to the back of the mounting plate by sliding
it into the slits in the same direction as the arrow. Using
Tapping Screw 4x12 from the INSTALLATION HARDWARE,
tighten into place.
VERTICAL EXHAUST: Rotate hood fan unit 90˚ so that the
fan blade openings are facing the top of the oven. Replace
hood fan unit into oven unit.
•Put the lead wire into the box.
•Replace the fan cover bracket. If the cover does not
fit properly, the hood fan unit is improperly placed.
Follow the steps in figure ! again.
•Attach the fan cover bracket to the oven unit.
Exhaust Damper
Assembly
figure
figure
VERTICAL EXHAUST: Attach the Exhaust Damper
Assembly to the fan cover on the top of the outercase
E5
cabinet by sliding it into the slits in the same direction
as the arrow mark. Tapping Screw 4x12 from the
INSTALLATION HARDWARE, tighten into place.
Oven Installation
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
THIS OVEN CANNOT BE PROPERLY INSTALLED WITHOUT
REFERRING TO THE MOUNTING INSTRUCTIONS
FOUND ON WALL AND TOP CABINET TEMPLATES.
Mounting Plate
•Separate 4 Toggle Bolts, packed in the INSTALLATION
HARDWARE, from the Toggle Nuts.
Toggle Bolt
Toggle Nut
figure
figure
Mounting Plate
MOUNTING PLATE: Use wood screws to attach mounting
plate to the stud or studs. Use Toggle Bolts to attach
mounting plate through the holes at A, B, C and D UNLESS
THOSE HOLES ARE LOCATED ON THE STUD. Inser t one
Toggle Bolt into A, B, C and D where appropriate (these
correspond to holes of the Wall Template) and put the
Toggle Nuts onto the Toggle Bolts.
NOTE:
Before insertion, be sure you leave a space more than
the thickness of the wall between the Mounting Plate
and the end of each of the Toggle Nuts (in the closed
position). If you do not leave enough space, the Toggle
Nut will not be able to open on the other side of the wall.
Also, once a Toggle Nut opens, it cannot be withdrawn
from the hole; therefore make sure all of the Toggles are
in the correct position before insertion.
figure
figure
MOUNTING PLATE: Align the Mounting Plate carefully
and hold in position while tightening Toggle Bolts. Pull
Toggle Bolt toward you and turn clockwise to tighten.
•Refer to instructions in Wall Template.
figure
figure
MOUNTING PLATE: Position the Mounting Plate with
the Toggle Bolts attached at the wall location and insert
Toggle Nuts and Bolts through the holes in the wall with
the Toggle Nuts closed. Use Wood Screws to attach the
Mounting Plate to studs.
Wall
Space more
than wall
thickness
Mounting Oven to the Wall
Utilization of the carton may make installation easier.
figure
figure
Top Side
Cutting Line
MOUNTING OVEN TO THE WALL: Place carton upside
down.
E6
Oven Installation
(B)
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
(A)
(B)
(B)
(C)
(D)
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
(A)
figure
figure
(B)
MOUNTING OVEN TO THE WALL: Using cutting line
around the carton, cut into two pieces (A) and (B).
figure
figure
(B)
figure
figure
MOUNTING OVEN TO THE WALL: Hang the oven on
the lower edge of the mounting plate. Take care that the
power cord is able to clear the edge of the hole as the
oven is rotated upward. (In the case of a non-recessed
bottom in the top cabinet, the hole for the cord may
need to be enlarged.) Remove the carton portions.
figure
figure
MOUNTING OVEN TO THE WALL: Place the oven and
the carton portions together on the top of the range.
Slide carton toward backguard until it stops. Align the
lower back edge of the oven with the mounting plate.
Thread the power supply cord through the hole made in
the bottom of the top cabinet.
MOUNTING OVEN TO THE WALL: Tighten the two unit
Mounting Screws located in the grease filter openings.
E7
Mounting Screws
Oven Installation
(B)
(C)
(D)
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
figure
Deflector
MOUNTING OVEN TO THE WALL: Install Grease
Filters by fitting into the opening. Push back and up
into place.
(C)
figure
figure
(D)
MOUNTING OVEN TO THE WALL: Use the two Top
Cabinet Screws (C) and two Flat Washers (D), supplied
in the INSTALLATION HARDWARE, to attach the unit to
the top cabinet.
MOUNTING DEFLECTOR: Secure the deflector with 3
Tapping Screws 4 x 12mm, packed in the Installation
Hardware.
Checklist for Installation
• Make sure the unit has been installed according to all of
the Installation Instructions and the Wall and Top Cabinet
Templates.
• Plug in the power cord.
• Keep the Operation Manual.
Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-845-4641
E8
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.