Viking RVGR33025BSSLP, RVDR33025BSS Installation

0 (0)
to Natural gas,

RLPKR2 LP Conversion Kit Instructions for RVGR3302/RVDR3302 Ranges

W A R N I N G

The conversion must be performed by a qualified installer or gas supplier in accordance with the manufacturer’s instructions and all codes and

requirements of the authority having jurisdiction. Failure to follow ALL instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for this conversion.

The pressure regulator and the burner orifices are set for Natural gas. To use Liquid Propane gas, the regulator and burner orifices must be converted.

To convert the range to LP gas, follow these instructions:

1.Disconnect all electrical power at the main circuit breaker or fuse box.

2.Shut off the gas supply to the range by closing the manual shut-off valve.

Converting the Pressure Regulator

1.Locate the pressure regulator which can be found on the back of the range on the right hand side if facing the back of the range.

2.Unscrew the hex nut cap from the top of the regulator.

3.Unsnap the plastic plunger from the hex nut.

4.Reverse the plunger and reinstall onto the hex nut by pressing firmly.

Note: Plunger is marked “Nat” and “LP”. Converted fuel type will be shown on the lower portion of the plunger.

NAT

LP

Apply sideways finger pressure to remove pin from cap.

conversion

LP

N AT

conversion

LP

N AT

Converting the Surface Burners

1. Remove the top grates, burner caps, and burner heads.

Burner grate

Burner cap

Burner head

Orifice Burner spud base

2.Using a 9/32” or 7 mm nut driver remove the top burner orifices. These may be accessed through the opening in the burner base.

Note: Save these orifices for future conversion back if required.

3. Locate the proper LP surface

 

0.

Orifice

burner orifices included with

79

 

stamp

the kit according to the chart

Orifice

 

below. The orifice stamp can

 

 

 

be either the metric diameter

 

 

size or the orfice drill size.

 

 

4.Install the orifices in their correct location. To prevent leakage, make sure the orifice spuds are securely screwed into the burner base.

Part Number

Burner

BTU Rate

Diameter

Orifice

 

 

 

mm

Stamp

057741-901

Left front (A)

16,000

1.19

119

 

 

 

 

 

057741-902

Left rear (B)

6,500

0.71

71

 

 

 

 

 

057741-903

Center (C)

8,000

0.85

85

057741-905

Right rear (D)

11,000

0.95

95

 

 

 

 

 

057741-904

Right front (E)

15,000

1.15

115

035282-000

Bake

30,000

1.68

1.68

035283-000

Broil

14,500

1.03

1.03

 

 

 

 

 

B

C

D

A

 

E

1-EN

Converting the Bake Burner

1.Remove oven racks and oven support.

2.Remove oven bottom.

3.Remove screws securing bake igniter to bake burner.

4.Remove screws securing bake burner shield to oven burner box.

5.Remove screws securing bake burner to oven burner box.

6.Loosen air shutter screw and adjust opening on burner to 3/8” and tighten air shutter screw.

7.Remove orifice by turning counterclockwise and replace with orifice 1.68 from bag labeled.

Important: The orifice tip must be located 3/16” inside the burner for proper gas mixture and combustion. The depth of the orifice can be adjusted by turning the orifice counterclockwise (more depth) or clockwise (less depth). Reverse procedure as needed to reassemble.

A ir Sh u tte r

A ir Sh u tte r

Se t Scre w

Vo let d 'a

O r ifice

H o o d

Ad justment

 

 

 

 

 

Air Shutter

Sc rew

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Converting the Broil Burner

1.Remove the screws (4) from the broiler baffle.

2.Carefully remove the broiler burner

Note: Pay close attention to the igniter wire while removing the broiler burner.

3.Disconnect the igniter wire.

4.Use a 1/2” wrench to remove the broiler burner natural gas orifice hood and replace with LP broiler burner hood 1.03.

5.Reinstall the converted broiler burner by first firmly attaching

the igniter wire.

6.Reposition the broiler burner in its original position.

7.Replace the four screws into the broiler baffle.

Air Shutter Settings for Broiler Burner

1.Use a screwdriver to loosen the air shutter screw.

2.Adjust the air shutters for LP gas by rotating the shutter to the fully open position. Your final settings may vary.

3.Retighten the air shutter screw.

Bake and broiler flame must be checked with the door closed to

Air shutter

 

 

 

 

 

 

Adjustment screw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W A R N I N G

If you attempt to measure the inner cone of the flame, please use caution as burns could result.

properly check flame characteristics.

4.Turn on the gas.

5.Turn on the electricity.

6.Retighten the air shutter screw.

7.Turn on the bake and broiler burner.

8.As you watch the flame with the oven door closed, check the following through the oven door window:

a.If the flames are yellow, open the air shutter more.

b.If the flames blow away or flutter from the burner, close the air shutter more.

9.Open the oven door and check the inner cone of the bake and broiler burner flame. It should be approximately 1/2” to 3/4” long for the bake and broil burners. The combustion quality of the burner flames needs to be determined visually. With LP gas, some yellow tipping on the outer cones is normal.

10.When all adjustments are made and the results are satisfactory then replace the oven bottom cover.

In some cases, foreign particles in the gas line may cause an orange flame at first but this will soon disappear.

Note: To convert the oven back to Natural gas, reverse the instructions given for making the LP gas adjustments.

Note: When the LP/Propane conversion is finished, complete the enclosed conversion label and place it next to the rating label.

2-EN

Viking RVGR33025BSSLP, RVDR33025BSS Installation
to NAT gas, if

RNKR2 NAT Conversion Kit Instructions for RVGR3302/RVDR3302 Ranges

W A R N I N G

The conversion must be performed by a qualified installer or gas supplier in accordance with the manufacturer’s instructions and all codes and

requirements of the authority having jurisdiction. Failure to follow ALL instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for this conversion.

The pressure regulator and the burner orifices are set for LP gas. To use natural gas, the regulator and burner orifices must be converted.

To convert the range to NAT gas, follow these instructions:

1.Disconnect all electrical power at the main circuit breaker or fuse box.

2.Shut off the gas supply to the range by closing the manual shut-off valve.

Converting the Pressure Regulator

1.Locate the pressure regulator which can be found on the back of the range on the right hand side if facing the back of the range.

2.Unscrew the hex nut cap from the top of the regulator.

3.Unsnap the plastic plunger from the hex nut.

4.Reverse the plunger and reinstall onto the hex nut by pressing firmly.

Note: Plunger is marked “Nat” and “LP”. Converted fuel type will be shown on the lower portion of the plunger.

NAT

LP

Apply sideways finger pressure to remove pin from cap.

conversion

LP

N AT

conversion

LP

N AT

Converting the Surface Burners

1. Remove the top grates, burner caps, and burner heads.

Burner grate

Burner cap

Burner head

Orifice Burner spud base

2.Using a 9/32” or 7 mm nut driver remove the top burner orifices. These may be accessed through the opening in the burner base.

Note: Save these orifices for future conversion back required.

3. Locate the proper NAT surface

 

 

0.

Orifice

burner orifices included with

 

79

 

 

stamp

the kit according to the

Orifice

 

 

diagram below. The orifice

 

 

 

 

 

stamp can be either the metric

 

 

 

diameter size or the orfice drill size.

 

 

4.Install the orifices in their correct location. To prevent leakage, make sure the orifice spuds are securely screwed into the burner base.

Part Number

Burner

BTU Rate

Diameter

Orifice

 

 

 

mm

Stamp

057747-901

Left front (A)

18,000

2.00

200

 

 

 

 

 

057747-902

Left rear (B)

9,100

1.38

138

 

 

 

 

 

057747-903

Center (C)

9,100

1.38

138

 

 

 

 

 

057747-905

Right rear (D)

12,000

1.58

158

 

 

 

 

 

057747-904

Right front (E)

17,000

1.88

189

 

 

 

 

 

015695-000

Bake

30,000

2.58

#38

 

 

 

 

 

PB040034

Broil

15,000

1.87

#50

 

 

 

 

 

B

C

D

A

 

E

3-EN

Loading...
+ 5 hidden pages