Viking RVGC3305BSS Installation Guide

0 (0)
Viking RVGC3305BSS Installation Guide

Installation

Viking Range, LLC

111 Front Street

Greenwood, Mississippi 38930 USA

(662) 455-1200

For product information, call 1-888-845-4641 or visit the Viking Website at vikingrange.com

Built-In Gas Cooktops

F21209 EN

(051513)

Table of Contents

Warnings & Important Safety Instructions _______________________________________________3 Dimensions _________________________________________________________________________6 Specifications _______________________________________________________________________7 Cutout Dimensions __________________________________________________________________8 Cutout Dimensions (Cooktop over Single Electric Oven)__________________________________9 Downdraft Dimensions ______________________________________________________________9 Clearance Dimensions (Proximity to Cabinets)__________________________________________10 Clearance Dimensions (Wood/Composite Overlay) _____________________________________11 Electrical & Gas Requirements _______________________________________________________12 General Information ________________________________________________________________14 Installation _________________________________________________________________________15

Gas & Electrical Connection ______________________________________________________15 Bracket Installation ______________________________________________________________16 Final Installation ________________________________________________________________16 Final Preparation ___________________________________________________________________17 Performance Checklist ______________________________________________________________17 Service & Registration _______________________________________________________________18

IMPORTANT– Please Read and Follow

Before beginning, please read these instructions completely and carefully.

DO NOT remove permanently affixed labels, warnings, or plates from product. This may void the warranty.

All local and national codes and ordinances must be observed. Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code ANSI Z223.1 NFPA54-latest edition.

The installer must leave these instructions with the consumer for local inspector’s use and for future reference.

Installation of any gas-fired equipment should be made by a licensed plumber. A manual gas shut-off valve must be installed in the gas supply line ahead of the cooktop in the gas stream for safety and ease of service.

In Canada: Installation must be in accordance with the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.

In Massachusetts: All gas products must be installed by a “Massachusetts” licensed plumber or gasfitter. A “T” type handle manual valve must be installed in the gas supply line to the appliance.

An air curtain or other overhead range hood which operates by blowing a downward airflow onto the range, shall not be used with a gas appliance

Your safety and the safety of others is very important.

We have provided many important safety messages in this manual and on your appliance. ALWAYS read and obey all safety messages.

This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.

All safety messages will be preceded by the safety alert symbol and the word “DANGER,” “WARNING” or “CAUTION.” These words mean:

DANGER

Hazards or unsafe practices which WILL result in severe personal

injury or death

WARNING

Hazards or unsafe practices which COULD result in severe personal

injury or death

CAUTION

Hazards or unsafe practices which COULD result in minor personal injury or property damage.

All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

2

3

IMPORTANT– Please Read and Follow

DANGER

FIRE/EXPLOSION HAZARD

IF THE INFORMATION IN THIS MANUAL IS NOT

FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.

DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

DO NOT try to light any appliance.

DO NOT touch any electrical switch.

DO NOT use any phone in your building.

–Immediately call your gas supplier from a neighbor’s phone.

–Follow the gas supplier’s instructions. –If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

CAUTION

BURN HAZARD

The use of cabinets for storage above the appliance may result in a potential burn hazard. Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided the risk can be reduced by installing a range hood that projects horizontally a minimum of 5” (12.7 cm) beyond the bottom of the cabinets.

WARNING

CHEMICAL HAZARD

If not installed, operated and

maintained in accordance with the manufacturer’s

instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness and which are known to cause cancer, birth defects, or other reproductive harm.

For example, benzene is a chemical which is part of the gas supplied to the cooking product. It is consumed in the flame during combustion. However exposure to a small amount of benzene is possible if a gas leak occurs. Formaldehyde and soot are byproducts of incomplete combustion. Properly adjusted burners with a bluish rather than yellow flame will minimize incomplete combustion.

CAUTION

Before placing the cooktop into operation, always check for gas leaks with a soapy water solution or other acceptable method. DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS.

WARNING

This appliance shall not be used for space heating. This information is based on safety considerations.

IMPORTANT– Please Read and Follow

WARNING

ELECTRICAL GROUNDING INSTRUCTIONS

The cooktop must be electrically grounded in accordance with local codes or, in the absence of codes, with the ANSI/NFPA No. 70-latest edition. Installation should be made by a licensed electrician. This appliance is equipped with a three-prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded receptacle. DO NOT cut or remove the grounding prong from the plug.

For personal safety, this appliance must be properly grounded. DO NOT under any circumstances cut or remove the third (ground) prong from the power plug.

4

5

Loading...