Viking FDRB5303L, FDFB5303R Installation Guide

Installation
Custom Panel All Refrigerator / All Freezer
FDRB5303 / FDRB5363 / CFDRB5303 / CFDRB5363
FDFB5303 / FDFB5363 /CFDFB5303 / CFDCFB5363
2
Table of Contents
Warnings & Important Information ____________________________________________________________________3 All Refrigerator/Freezer
Custom Grille Dimensions (Dual 36”) ________________________________________________________27 Cabinet Information _______________________________________________________________________________28 Custom Side Panel Dimensions _____________________________________________________________________30 Custom Panel General Information __________________________________________________________________31 Custom Door Panel Installation ____________________________________________________________________ 32 Custom Grille Installation ___________________________________________________________________________34 General Information _______________________________________________________________________________36
Unpacking & Moving ______________________________________________________________________38 Installation ________________________________________________________________________________________39
Hinge Adjustment_________________________________________________________________________39
Kickplate Installation_______________________________________________________________________42
Door Stop Adjustment_____________________________________________________________________42
Final Installation __________________________________________________________________________43 Performance Checklist _____________________________________________________________________________44 Control Panels ____________________________________________________________________________________45 Service & Registration______________________________________________________________________________46
3
IMPORTANT – Please Read and Follow
• Make sure that incoming voltage is the same as
unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product.
• To reduce the risk of fire, electrical shock, or injury
to persons, installation work and electrical wiring must be done by a qualified technician in accordance with all applicable codes and standards, including fire-rated construction.
• The installer should leave these instructions with
the consumer who should retain them for local inspector’s use and for future reference.
It is your responsibility to:
• Comply with installation specifications and
dimensions.
• Properly install unit.
• Remove any moldings or decorative panels that
prevent the unit from being serviced.
• Make sure that you have these materials (not
provided with your unit), which are necessary for proper installation:
• 1/4” (6 mm) copper tubing with shutoff valve
• 6 – #8 x 3” (7.6 cm) wood screws (longer screws may be required)
• 1– Saddle valve (DO NOT use self-piercing feature of the valve)
• Assure that floor will support unit, door panels and contents (approximately 1200 pounds [540 kg]).
• Provide a properly grounded electrical outlet.
• Assure that location will permit appliance doors to open a minimum of 90˚.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance. ALWAYS read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others.
All safety messages will be preceded by the safety alert symbol and the word “DANGER” or “WARNING.” These words mean:
Hazards or unsafe practices
which WILL result in severe personal
injury or death
DANGER
Hazards or unsafe practices
which COULD result in severe personal
injury or death
All safety messages will identify the
hazard, tell you how to reduce the chance
of injury, and tell you what can happen if
the instructions are not followed.
WARNING
IMPORTANT – Please Read and Follow!
4
A GFI
shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or
local ordinances.
• The required use of a GFI is normally related to the location of a receptacle with respect to
any significant sources of water or moisture.
• Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not
installed properly or do not meet the requirements below.
If the use of a GFI is required
, it should be:
• Of the receptacle type (breaker type or portable type NOT recommended)
• Used with permanent wiring only (temporary or portable wiring NOT recommended)
• On a dedicated circuit (no other receptacles, switches or loads in the circuit)
• Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT
recommended)
• Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard)
• In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations)
• Protected from moisture (water, steam, high humidity) as much as reasonably possible
5
ELECTRICAL SHOCK HAZARD
Disconnect power or turn
power disconnect switch to OFF position before removing top grille. Failure to do so can result in death or electric shock.
WARNING
WARNING
TIP OVER HAZARD
Appliance is top heavy and tips easily when not completely installed. Keep
doors closed until appliance is completely installed and secured per installation instructions.
Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping. Use cardboard shipping material or plywood under unit until it is installed in the operating position to protect floor surface.
24”
(61.0 cm)
35”
(88.9 cm)
75–15/16”
(192.9 cm)
3–19/32”
(9.1 cm)
)
36”36”
(91.5 cm)(
91.5 cm
)
36”
(91.5 cm)
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
min.
to
84–1/16”
(213.5 cm)
max.
23-3/16”
(58.9 cm)
24”
(61.0 cm)
29”
(73.7 cm)
75–15/16”
(192.9 cm
)
3–19/32”
(9.1 cm)
30”30”
(76.2 cm)(76.2 cm)
30”
(76.2 cm)
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
min.
to
84–1/16”
(213.5 cm)
max.
23-3/16”
(58.9 cm)
Measurement varies
(locally supplied hardware)
Measurement varies
(locally supplied hardware)
Dimensions
6
30” All Refrigerator/Freezer
36” All Refrigerator/Freezer
7
Specifications
30 All Refrigerator/Freezer
Description FDFB/CFDFB FDRB/CFDRB
Overall width 30” (76.2 cm) Overall height (from bottom) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth (from rear) To front edge of side trim: 23-3/16” (58.9 cm)
To front edge of door trim: 24” (61.0 cm) Cutout width 30” (76.2 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min.* Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product Maximum amp usage 9.1 amps 5.7 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi Overall interior dimensions total capacity 15.9 cu. ft. (450 liters) 18.4 cu. ft. (522 liters) Maximum panel weight 50 lbs. (22.7 kg) Approximate shipping weight 445 lbs. (200.2 kg)
36 All Refrigerator/Freezer
Description FDFB/CFDFB FDRB/CFDRB
Overall width 36” (91.5 cm) Overall height (from bottom) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth (from rear) To front edge of side trim: 23-3/16” (58.9 cm)
To front edge of door trim: 24” (61.0 cm) Cutout width 36” (91.5 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min.* Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product Maximum amp usage 9.5 amps 6.5 amps Inlet water requirements 1/4” copper tubing inlet
waterline; minimum 20 psi; N/A
maximum 120 psi Overall interior dimensions total capacity 19.2 cu. ft. (544 liters) 22.0 cu. ft. (623 liters) Maximum panel weight 60 lbs. (27.2 kg)
Approximate shipping weight 520 lbs. (234 kg)
*Note: Custom panel models fit flush in 25” (63.5 cm) deep cabinet openings. They can be installed in standard 24” (61.0 cm) deep openings. The door faces and top grille will protrude 3/4” (1.9 cm) into the room.
8
Cutout Dimensions
30” All Refrigerator/Freezer
24”
(61.0 cm)
82-7/8”
(210.5 cm) min.
anti-tip board &
opening height
84-1/16”
(213.5 cm) max.
anti-tip board &
opening height
See anti-tip board installation
(22.9 cm)
73-3/8”
(186.4 cm)
9”
Electric Outlet Location
6”
(15.2 cm)
9”
(22.9 cm)
Water Line Entry Area
Note: Shown for All Freezer only.
3
(76.2 cm)
0”
3-5/8”
(9.2 cm)
10-3/4”
(27.3 cm)
Optional floor
water line entry
5/8”
(1.5 cm)
7-5/8”
(19.4 cm)
3”
(7.6 cm)
30”
(76.2 cm)
6-3/4”
(17.1 cm)
10-1/2”
(26.7 cm)
5/8”
(1.5 cm)
5/8”
(1.5 cm)
1”
(2.5 cm)
One 2”x 4” mounting board
1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim
behind the mounting boards by the difference.
Bottom of anti-tip board is 3-7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Anti-Tip Location
79-3/8”
(201.6 cm) min.
to bottom of anti-tip board
80-1/2”
(204.6 cm) max.
to bottom of anti-tip board
23”
(58.4 cm)
3-1/2”
(8.9 cm)
1-1/2”
(3.8 cm)
9
Anti-Tip Dimensions
30” All Refrigerator/Freezer
One 2”x4” mounting board 1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting board by the difference.
Bottom of anti-tip board is 3-7/8” (9.8 cm) below the opening height.
Note: Top of unit must be placed firmly under anti-tip board.
10
Cutout Dimensions
36” All Refrigerator/Freezer
24”
(61.0 cm)
82-7/8”
(210.5 cm) min.
anti-tip board &
opening height
84-1/16”
(213.5 cm) max.
anti-tip board &
opening height
3
(91.5 cm)
6”
See anti-tip board installation
9”
(22.9 cm)
73-3/8”
(186.4 cm)
5/8”
(1.5 cm)
Electric Outlet Location
6”
(15.2 cm)
9”
(22.9 cm)
Water Line Entry Area
Note: Shown for All Freezer only.
36”
7-5/8”
(19.4 cm)
3”
(7.6 cm)
(91.5 cm)
6-3/4”
(17.1 cm)
3-5/8”
(9.2 cm)
10-3/4”
(27.3 cm)
Optional floor
water line entry
10-1/2”
(26.7 cm)
5/8”
(1.5 cm)
(1.5 cm)
1”
(2.5 cm)
5/8”
One 2”x 4” mounting board
1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim
behind the mounting boards by the difference.
Bottom of anti-tip board is 3-7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Anti-Tip Location
79-3/8”
(201.6 cm) min.
to bottom of anti-tip board
80-1/2”
(204.6 cm) max.
to bottom of anti-tip board
29”
(73.7 cm)
3-1/2”
(8.9 cm)
1-1/2”
(3.8 cm)
11
Anti-Tip Dimensions
36” All Refrigerator/Freezer
One 2”x4” mounting board 1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting board by the difference.
Bottom of anti-tip board is 3-7/8” (9.8 cm) below the opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Dimensions
12
Dual 30” All Refrigerator/Freezer
3-1/2”
(8.9 cm)
75-15/16”
(192.9 cm)
30”
(76.2 cm)
29”
(73.7 cm)
30”
(76.2 cm)
29”
(73.7 cm)
9–5/32”
(23.3 cm)
29-1/2”
(74.9 cm)
Measurement varies
(locally supplied hardware)
1”
(2.54 cm)
between units
29-1/2”
(74.9 cm)
23-3/16”
(58.9 cm)
24-3/4”
(62.9 cm)
82–3/4”
(210.2 cm)
min.
to
84–1/16”
(213.5 cm)
max.
Dimensions
13
Dual 30” & 36” All Refrigerator/Freezer
3-1/2”
(8.9 cm)
75-15/16”
(192.9 cm)
30”
(76.2 cm)
29”
(73.7 cm)
36”
(91.5 cm)
35”
(88.9 cm)
9–5/32”
(23.3 cm)
29-1/2”
(74.9 cm)
Measurement varies
(locally supplied hardware)
1”
(2.54 cm)
between units
35-1/2”
(90.2 cm)
23-3/16”
(58.9 cm)
24-3/4”
(62.9 cm)
82–3/4”
(210.2 cm)
min.
to
84–1/16”
(213.5 cm)
max.
Dimensions
14
Dual 36” All Refrigerator/Freezer
35”
(88.9 cm)
3-1/2”
(8.9 cm)
75-15/16”
(192.9 cm)
36”
(91.5 cm)
36”
(91.5 cm)
Measurement varies
(locally supplied hardware)
35”
(88.9 cm)
9–5/32”
(23.3 cm)
82–3/4”
(210.2 cm)
min.
to
84–1/16”
(213.5 cm)
max.
35-1/2”
(90.2 cm)
1”
(2.54 cm)
between units
35-1/2”
(90.2 cm)
23-3/16”
(58.9 cm)
24-3/4”
(62.9 cm)
Specifications
15
Dual All Refrigerator/Freezer*
Description (2) 30 Units (1) 36 & (1) 30 Unit (2) 36” Units
Overall width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm) Overall height (from bottom) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. Overall depth (from rear) To front edge of side trim: 23-3/16” (58.9 cm)
To front edge of door trim: 24” (61.0 cm) Cutout width 60” (152.4 cm) 66” (167.6 cm) 72” (182.9 cm) Cutout height 82-7/8” (210.5 cm) min. to 84-1/16” (213.5 cm) max. Cutout depth 24” (61.0 cm) min.** Electrical requirements (2) 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with
grounded 3-prong plug attached to product
Maximum amp usage FDFB 30” - 9.1 amps
FDRB 30” - 5.7 amps FDFB 36” - 9.5 amps
FDRB 36” - 6.5 amps Inlet water requirements 1/4” copper tubing inlet waterline; minimum 20 psi; (All Freezer only) maximum 120 psi Overall interior dimensions
30” freezer 15.9 cu. ft. (450 liters) 30” refrigerator 18.4 cu. ft. (522 liters) 36” freezer 19.2 cu. ft. (544 liters) 36” refrigerator 22.0 cu. ft. (623 liters)
Maximum panel weight
30” freezer or refrigerator
50 lbs. (22.7 kg)
36” freezer or refrigerator
60 lbs. (27.2 kg)
Approximate shipping weight
30” freezer or refrigerator 445 lbs. (200.2 kg) 36” freezer or refrigerator 520 lbs. (234 kg)
*For installation of two units side-by-side, a separate grille kit accessory must be purchased.
**Note: Custom panel models fit flush in 25” (63.5 cm) deep cabinet openings. They can be installed in standard 24” (61.0 cm) deep openings. The door faces and top grille will protrude 3/4” (1.9 cm) into the room.
16
Cutout Dimensions
Dual 30” All Refrigerator/Freezer
24”
(61.0 cm)
82-7/8”
(210.5 cm) min.
anti-tip board &
opening height
84-1/16”
(213.5 cm) max.
anti-tip board & opening height
See anti-tip board installation
9”
(22.9 cm)
73-3/8”
(186.4 cm)
Electric outlet location
6”
(15.2 cm)
9”
(22.9 cm)
Water Line Entry Area
Note: Cutout opening shown with All Freezer model on left.
Reverse water line entry if All Freezer model is on right.
60”
(152.4 cm)
(1.5 cm)
3-5/8”
(9.2 cm
10-3/4”
(
27.3 cm)
5/8”
7-5/8”
(19.4 cm)
3
(7.6 cm)
)
Optional floor
water line entry
6-3/4”
(17.1 cm)
10-1/2”
(26.7 cm)
5
/8”
(1.5 cm)
60”
(152.4 cm)
5
/8”
(1.5 cm)
1”
(2.5 cm
)
17
Anti-Tip Dimensions
Dual 30” All Refrigerator/Freezer
One 2”x4” mounting board per unit 1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting board by the difference.
Bottom of anti-tip board is 3-7/8” (9.8 cm) below the opening height.
Note: Top of unit must be placed firmly under anti-tip board.
79-3/8”
(201.6 cm) min.
to bottom of anti-tip board
Anti-Tip Location
80-1/2”
(204.6 cm) max.
to bottom of anti-tip board
23”
(58.4 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim
Bottom of anti-tip board is 3-7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
One 2”x 4” mounting board per unit
1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
behind the mounting boards by the difference.
1-1/2”
(3.8 cm)
3-1/2”
(8.9 cm)
23”
(58.4 cm)
18
Cutout Dimensions
Dual 30” & 36” All Refrigerator/Freezer
24”
(61.0 cm)
See anti-tip board installation
Electric Outlet Location
6”
(15.2 cm)
82-7/8”
(210.5 cm) min.
anti-tip board &
opening height
84–1/16”
(213.5 cm) max.
anti-tip board & opening height
66”
(167.6 cm)
9”
(22.9 cm)
73-3/8”
(186.4 cm)
5
/8”
(1.5 cm)
3-5/8”
(9.2 cm
)
10-3/4”
(
27.3 cm)
Optional floor
water line entry
9”
(22.9 cm)
Water Line Entry Area
Note: Cutout opening shown with All Freezer model on left.
Reverse water line entry if All Freezer model is on right.
7-5/8”
(19.4 cm)
3
(7.6 cm)
6-3/4”
(17.1 cm)
10-1/2”
(26.7 cm)
5/8”
(1.5 cm)
66”
(167.6 cm)
5
/8”
(1.5 cm)
1”
(2.5 cm
)
19
Anti-Tip Dimensions
Dual 30” & 36” All Refrigerator/Freezer
One 2”x4” mounting board per unit 1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting board by the difference.
Bottom of anti-tip board is 3-7/8” (9.8 cm) below the opening height.
Note: Top of unit must be placed firmly under anti-tip board.
Note: Dimensions shown for 36” All Freezer/All Refrigerator model on the left. Reverse mounting boards if untis are installed on the right.
79-3/8”
(201.6 cm) min.
to bottom of
anti-tip board
Anti-Tip Location
80-1/2”
(204.6 cm) max.
to bottom of
anti-tip board
29”
(73.7 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim
Bottom of anti-tip board is 3-7/8” (9.8 cm) below opening height.
Note: Dimensions shown for 36” All Freezer/All Refrigerator model on the left.
Note: Top of unit must be placed firmly under anti-tip board.
Reverse mounting boards if units are installed on the right.
One 2”x 4” mounting board per unit
1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
behind the mounting boards by the difference.
1-1/2”
(3.8 cm)
3-1/2”
(8.9 cm)
23”
(58.4 cm)
24”
Cutout Dimensions
20
Dual 36” All Refrigerator/Freezer
(61.0 cm)
See anti-tip board installation
Electric Outlet Location
6”
(15.2 cm)
82-7/8”
(210.5 cm) min.
anti-tip board &
opening height
84-1/16”
(213.5 cm) max.
anti-tip board &
opening height
72”
(182.9 cm)
9”
(22.9 cm)
73-3/8”
(186.4 cm)
5
/8”
(1.5 cm)
3-5/8”
(9.2 cm
)
10-3/4”
(
27.3 cm)
Optional floor
water line entry
9”
(22.9 cm)
Water Line Entry Area
Note: Cutout opening shown with All Freezer model on left.
Reverse water line entry if All Freezer model is on right.
7-5/8”
(19.4 cm)
3
(7.6 cm)
6–3/4”
(17.1 cm)
10-1/2”
(26.7 cm)
5/8”
(1.5 cm)
72”
(182.9 cm)
5
/8”
(1.5 cm)
1”
(2.5 cm
)
Anti-Tip Dimensions
21
Dual 36” All Refrigerator/Freezer
One 2”x4” mounting board per unit 1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim behind the mounting board by the difference.
Bottom of anti-tip board is 3-7/8” (9.8 cm) below the opening height.
Note: Top of unit must be placed firmly under anti-tip board.
79-3/8”
(201.6 cm) min.
to bottom of anti-tip board
Anti-Tip Location
80-1/2”
(204.6 cm) max.
to bottom of anti-tip board
29”
(73.7 cm)
Note: If unit is installed deeper than 24” (61.0 cm), then shim
Bottom of anti-tip board is 3-7/8” (9.8 cm) below opening height.
Note: Top of unit must be placed firmly under anti-tip board.
One 2”x 4” mounting board per unit
1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)
behind the mounting boards by the difference.
1-1/2”
(3.8 cm)
3-1/2”
(8.9 cm)
29”
(73.7 cm)
35-1/4”
(89.5 cm)
75-1/2”
(191.8
cm
)
3/4”
(1.9 cm)
29-1/4”
(74.3 cm)
75-1/2”
(191.8 cm)
3/4”
(1.9 cm)
Overlay Dimensions
22
30” Custom Panels
36” Custom Panels
Note: Hardware placement can vary depending on single or dual installation.
Note: Panel overlays must be dry, solid, straight one piece panels. The use of multiple panel pieces to achieve the dimensions is not recommended.
1/4” Radius
(1.2 cm)
3/
8
” R
a
d
iu
s
(.
95
cm)
Custom Grille Dimensions
23
30” Custom Grille
Note: Optional hinge cover can be attached using a strong VHB tape, countersunk wood screws or short nails from a nail gun.
1/2”
(1.27 cm)
1/4” Radius
1/4” Radius
(1.2 cm)
(.64 cm)
1/8”
(.31 cm)
Reverse dimensions
for other end.
3/4”
(1.90 cm)
1/2”
(1.27 cm)
3”
(7.62 cm)
3-3/4”
(9.52 cm)
3”
(7.62 cm)
3/4”
(1.90 cm)
4-11/64”
(10.59 cm)
5-17/32”
(14.10 cm)
1-1/2”
(3.81 cm)
1/4” Radius
24-27/32”
(63.10 cm)
26-3/16”
(66.51 cm)
2-3/4”
(6.98 cm)
(.64 cm)
(1.90 cm)
1/2”
(1.27 cm)
3/4”
1/2”
(1.27 cm)
1/2”
(1.27 cm)
3-1/8”
(7.93 cm)
1/2”
(1.27 cm)
3/4”
(1.90 cm)
3-5/8”
(9.20 cm)
3-3/4”
(9.52 cm)
Optional hinge cover
29-1/2”
(74.93 cm)
28”
(71.12 cm)
27-15/16”
(70.96 cm)
28”
(71.12 cm)
(9.20 cm)
3/8” Radius
3/8” Radius
(.95 cm)
(.95 cm)
3-5/8”
(.95
3/8”
cm)
1-3/8”
(3.49 cm)
2-1/8”
(5.39 cm)
(1.27 cm)
-1/8”
3
(7.94 cm)
1/2”
7/8”
(2.22 cm)
3/8” Radiu
s
(.
95
cm)
1/4” Radius
(1.2 cm)
Custom Grille Dimensions
24
36” Custom Grille
Note: Optional hinge cover can be attached using a strong VHB tape, countersunk wood screws or short nails from a nail gun.
1/2”
(1.27 cm)
1/4” Radius
1/4” Radius
(1.2 cm)
(.64 cm)
1/8”
(.31 cm)
Reverse dimensions
for other end.
1/2”
(1.27 cm)
3”
(7.62 cm)
3”
(7.62 cm)
3/4”
(1.90 cm)
4-11/64”
(10.59 cm)
5-17/32”
(14.10 cm)
1-1/2”
(3.81 cm)
30-27/32”
(78.34 cm)
2-3/4”
(6.98 cm)
1/4” Radius
(.64 cm)
(1.90 cm)
1/2”
(1.27 cm)
3/4”
1/2”
(1.27 cm)
1/2”
(1.27 cm)
3-1/8”
(7.93 cm)
3/4”
(1.90 cm)
1/2”
(1.27 cm)
3/4”
(1.90 cm)
3-3/4”
(9.52 cm)
3-5/8”
(9.20 cm)
3-3/4”
(9.52 cm)
Optional hinge cover
35-1/2”
(90.17 cm)
34”
(86.36 cm)
33-15/16”
(86.20 cm)
34”
(86.36 cm)
32-3/16”
(81.75 cm)
3/8” Radius
3/8” Radius
(.95 cm)
(.95 cm)
1-3/8”
(3.49 cm)
1
(1.27 cm)
/2”
7/8”
(2.22 cm)
2-1/8”
3/8”
cm)
(5.39 cm)
3
-1/8”
(7.94 cm)
3-5/8”
(9.20 cm)
(.95
1/4” Radius
(1.2 cm)
3/
8
” R
a
dius
(.95
cm)
Custom Grille Dimensions
25
Dual 30” Custom Grille
Note: Dual units can only be made in a left and right hand configuration.
Note: To use a custom grille on a dual installation, you must purchase the center trim kit FCTKSS.
Note: Optional hinge cover can be attached using a strong VHB tape, countersunk wood screws or short nails from a nail gun.
1/2”
(1.27 cm)
1/4” Radius
1/4” Radius
(1.2 cm)
(.64 cm)
1/8”
(.31 cm)
Reverse dimensions
for other end.
3/4”
(1.90 cm)
1/2”
(1.27 cm)
3/4”
(1.90 cm)
3-3/4”
(9.52 cm)
3-5/8”
(9.20 cm)
3-3/4”
(9.52 cm)
3-1/8”
(7.93 cm)
1/2”
(1.27 cm)
1/2”
(1.27 cm)
3”
(7.62 cm)
3”
(7.62 cm)
3/4”
(1.90 cm)
4-11/
(11.27 cm)
64”
58”
(147.32 cm)
57-15/16”
(147.16 cm)
5-17/32”
(14.04 cm)
24-27/32”
(63.01 cm)
1-1/2”
(3.81 cm)
26-3/16”
(66.80 cm)
2-3/4”
(6.98 cm)
1/4” Radius
(.64 cm)
34-11/64”
(86.80 cm)
1/2”
(1.27 cm)
35-25/64”
(89.90 cm)
3/4”
(1.90 cm)
1/2”
(1.27 cm)
(1.90 cm)
13/32”
(1.03 cm)
3/4”
(1.90 cm)
3/4”
(1.90 cm)
54-27/32”
(1
39.30 cm)
3/4”
1/8”
(.32 cm)
9/16”
(1.43 cm)
Grille support
2-7/8”
(7.30 cm)
1”
(2.54 cm)
Note: This part should be located at the center of the grille. If desired, two per grille can be used by dividing the length of the grille into thirds.
56-3/
(1
64”
42.36 cm)
1/2”
(1.27 cm)
R 3/32”
(0.09 cm)
3/8”
(0.38 cm)
58”
(147.32 cm)
Optional hinge cover
59-1/2”
(151.13 cm)
1/2”
(1.27 cm
3/8” Radius
3/8” Radius
(.95 cm)
(.95 cm)
3-5/8”
(9.20 cm)
)
3/8”
cm)
(.95
1-3/8”
(3.49 cm)
2-1/8”
(5.39 cm)
7/8”
(2.22 cm)
-1/8”
3
(7.94 cm)
1/4” Radius
(1.2 cm)
3/
8
” R
a
diu
s
(.
95 cm)
Custom Grille Dimensions
26
Dual 30” & 36” Custom Grille
Note: Dual units can only be made in a left and right hand configuration.
Note: To use a custom grille on a dual installation, you must purchase the center trim kit FCTKSS.
Note: 30” unit is on left and 36” unit is on right.
Note: Optional hinge cover can be attached using a strong VHB tape, countersunk wood screws or short nails from a nail gun.
1/2”
(1.27 cm)
1/4” Radius
1/4” Radius
(1.2 cm)
(.64 cm)
1/8”
(.31 cm)
Reverse dimensions
for other end.
3/4”
(1.90 cm)
1/2”
(1.27 cm)
3/4”
(1.90 cm)
3-3/4”
(9.52 cm)
3-5/8”
(9.20 cm)
3-3/4”
(9.52 cm)
3-1/8”
(7.93 cm)
1/2”
(1.27 cm)
1/2”
(1.27 cm)
(7.62 cm)
3”
3”
(7.62 cm)
3/4”
(1.90 cm)
4-11/
(11.27 cm)
64”
64”
(162.56 cm)
63-15/16”
(167.48 cm)
5-17/
(14.04 cm)
32”
24-27/32”
(63.10 cm)
1-1/2”
(3.81 cm)
26-3/
(66.51 cm)
16”
2-3/4”
(6.98 cm)
1/4” Radius
(.64 cm)
34-11/64”
(86.80 cm)
(1.90 cm)
1/2”
(1.27 cm)
35-25/64”
(89.90 cm)
3/4”
1/2”
(1.27 cm)
3/4”
(1.90 cm)
13/32”
(1.03 cm)
3/4”
(1.90 cm)
3/4”
(1.90 cm)
60-27/32”
(1
54.54 cm)
1/8”
(.32 cm)
9/16”
(1.43 cm)
1/2”
(1.27 cm)
R 3/32”
(0.09 cm)
3/8”
(0.38 cm)
Grille support
2-7/8”
(7.30 cm)
1”
(2.54 cm)
Note: This part should be located at the center of the grille. If desired, two per grille can be used by dividing the length of the grille into thirds.
62-3/
(1
64”
57.60 cm)
64”
(162.56 cm)
Optional hinge cover
65-1/2”
(166.37 cm)
1/2”
(1.27 cm)
3/8” Radius
3/8” Radius
(.95 cm)
(.95 cm)
3-5/8”
(9.20 cm)
3/8”
(.95
cm)
1-3/8”
(3.49 cm)
2-1/8”
(5.39 cm)
7/8”
(2.22 cm)
-1/8”
3
(7.94 cm)
1/4” Radius
(1.2 cm)
3/
8
” R
a
dius
(.95
cm)
Custom Grille Dimensions
27
Dual 36” Custom Grille
Note: Dual units can only be made in a left and right hand configuration.
Note: To use a custom grille on a dual installation, you must purchase the center trim kit FCTKSS.
Note: Optional hinge cover can be attached using a strong VHB tape, countersunk wood screws or short nails from a nail gun.
1/2”
(1.27 cm)
1/4” Radius
1/4” Radius
(1.2 cm)
(.64 cm)
1/8”
(.31 cm)
Reverse dimensions
for other end.
3/4”
(1.90 cm)
1/2”
(1.27 cm)
3/4”
(1.90 cm)
3-3/4”
(9.52 cm)
3-5/8”
(9.20 cm)
3-3/4”
(9.52 cm)
3-1/8”
(7.93 cm)
1/2”
(1.27 cm)
1/2”
(1.27 cm)
3”
(7.62 cm)
3”
(7.62 cm)
3/4”
(1.90 cm)
4-11/
(11.27 cm)
64”
70”
(177.80 cm)
69-15/16”
(177.64 cm)
5-17/32”
(14.04 cm)
30-27/32”
(78.34 cm)
1-1/2”
(3.81 cm)
32-3/
(81.75 cm)
16”
2-3/4”
(6.98 cm)
1/4” Radius
(.64 cm)
40-11/64”
(1
02.04 cm)
(1.90 cm)
1/2”
(1.27 cm)
41-25/64”
(1
05.13 cm)
3/4”
1/2”
(1.27 cm)
(1.90 cm)
13/32”
(1.03 cm)
3/4”
(1.90 cm)
3/4”
(1.90 cm)
66-27/32”
169.78 cm)
3/4”
1/8”
(.32 cm)
9/16”
(1.43 cm)
Grille support
2-7/8”
(7.30 cm)
1”
(2.54 cm)
Note: This part should be located at the center of the grille. If desired, two per grille can be used by dividing the length of the grille into thirds.
68-3/
(172.84 cm)
64”
1/2”
(1.27 cm)
R 3/32”
(0.09 cm)
3/8”
(0.38 cm)
70”
(177.80 cm
Optional hinge cover
71-1/2”
(181.61 cm)
(9.20 cm)
1/2”
(1.27 cm)
3/8” Radius
3/8” Radius
(.95 cm)
(.95 cm)
3-5/8”
3/8”
(.95
cm)
(2.22 cm)
1-3/8”
(3.49 cm)
2-1/8”
(5.39 cm)
7/8”
-1/8”
3
(7.94 cm)
28
25”
(63.5 cm)
countertop
depth
Cabinet Information
Custom panel models, (with 3/4” [1.9 cm], thick panels and custom handles locally supplied), fit flush in 25” (63.5 cm) deep (countertop depth) cabinet openings with no protrusion into room except custom handles
Top View
Wall
1/4”
(.63 cm) space if
25” (63.5 cm)
cabinet depth
is used
3/4”
(1.9 cm)
overlay
panel
Door
3/4”
(1.9 cm)
full end panel
1/8”
(0.3 cm)
foam
25”
25”
(63.5 cm)
(63.5 cm)
countertop
countertop
depth
depth
24”
(61.0 cm)
standard
cabinet
depth
25”
(63.5 cm)
Top View
Wall
3/4”
(1.9 cm) full end panel
Flush
1/4”
(.63 cm)
space if 25” (63.5 cm) cabinet depth
is used
3/4”
(1.9 cm)
overlay
(0.3 cm)
panel
Flush
1/8”
foam
Door
24”
(61.0 cm)
standard
cabinet
dep
t
h
Cabinet Information
29
Custom panel models can be installed in standard 24” (61.0 cm) deep openings. However, the door faces and top ventilation grille will protrude 3/4” (1.9 cm) into the room. This is ideal for alignment with full overlay cabinet doors.
Top View
Flush mount cabinet doors
Wall
24”
24”
(61.0 cm)
(61.0 cm)
standard
standard
cabinet
cabinet
depth
depth
Door
3/4”
(1.9 cm)
overlay
panel
3/4”
(1.9 cm)
full end panel
1/8”
(0.3 cm)
foam
Flush
24-3/4”
(62.9 cm)
Cabinet
door
3/4”
(1.9 cm)
End panel
1”
(2.5 cm)
1/4”
(0.6 cm)
Z-Bracket
Custom Side Panel Dimensions
30
*Note: Depending on how high leveling feet are raised, and cabinet enclosure height.
Note: Adding 3/4” (1.9 cm) side panels adds an additional 3/4” (1.9 cm) to the overall width of the product for each side panel used.
Note: Requires side panel hardware kit (SPHKDS).
21-3/4”
(55.2 cm)
21-3/4”
(55.2 cm)
82-7/8”
(210.5 cm
) min.
to
84-1/16”
(213.5 cm) max.*
Optional kickplate notch
(Dimensions determined by cabinets)
24”
(61.0 cm)
24”
(61.0 cm)
82-7/8”
(210.5 cm) min.
to
84-1/16”
(213.5 cm) max.*
31
Custom Panel General Information
Custom finishing options
• All installations must allow for the refrigerator and freezer door to open a minimum of 90˚.
• For side wall or corner installation, allow for a standard 3” (7.6 cm) cabinet filler to assure door(s) opens 90˚.
Note: If a custom handle is used, a wider filler may be necessary.
• Panel thickness must not exceed 1” (2.5 cm) on hinge side. Thicker panels will interfere with door swing and clearance.
• Door panels should be installed after the refrigerator has been plugged in for at least 24 hours.
32
Remove handle side cabinet screws
and trim with a phillips screwdriver.
Remove all screws from handle side door trim.
Remove two screws from top and bottom door trim.
Remove handle side door trim.
Remove bracket.
Measure and mark the first hole for each bracket.
Push custom wood panel onto door.
1
x13
2
x13
x2
x2
3
2-1/16”
(5.2 cm)
2-1/16”
(5.2 cm)
Back of panelBack of panel
FOL bracketFOL bracket“Z” bracket“Z” bracket
1-11/16”
(4.3 cm)
1-11/16”
(4.3 cm)
2-13/16”
(7.1 cm)
Bottom-mount
12-1/16”
(30.6 cm)
All Refrigerator/
Freezer/
Side-by-side
2-13/16”
(7.1 cm)
Bottom-mount
12-1/16”
(30.6 cm)
All Refrigerator/
Freezer/
Side-by-side
2-1/8”
(5.4 cm)
2-1/8”
(5.4 cm)
2-1/8”
(5.4 cm)
4
5
x13
x13 SxS, AFAR
x12 BTM
6
Custom Door Panel Installation
Attach “Z” bracket to the hinge side of custom panel.
Attach bracket to the handle side of custom panel.
51
7
Slide custom wood panel to the hinge side, ensuring
“Z” bracket engages the door bracket.
8
x13
x2
x2
Reinstall handle side door trim
and door trim screws.
Custom Door Panel Installation
9
x13
Reinstall cabinet trim and screws.
34
1
2
Remove air grille center blade.
Remove two 1/4” (0.6 cm) screws with a magnetic
extended screwdriver at least 8” (20.3 cm) long.
3
4
Pull air grille assembly forward.
Remove 2 mounting brackets from
the grille air assembly.
5
6
Using eight screws removed from the mounting brackets, attach mounting brackets to the custom wood grille using predrilled pilot holes. (See grille overlay specifications for
proper alignment and pilot hole placement.)
Insert custom air grille assembly.
Custom Grille Installation
35
Install two 1/4” (0.6 cm) screws with a magnetic extended screwdriver at least 8” (20.3 cm) long.
Install custom air grille center blade.
7
8
Custom Grille Installation (cont.)
36
General Information
Area Requirements
Verify the following:
• Unit can fit into residence and can be moved around corners and through doorways.
• Floors can support unit’s weight plus food weight (approximately 1200 pounds [540 kg] per unit).
• Floors underneath refrigerator are level with surrounding finished floor.
• Rear wall is solid and is able to support two horizontally mounted 2 x 4s (included) bolted to two wall studs. The 2 x 4 board bolt heads must be flush with 2 x 4 to prevent obstruction.
• Remove anything attached to rear or side walls that can obstruct unit installation.
• Cutout dimensions are accurate.
• Electrical outlet is in correct location.
• Water line is in correct location.
• DO NOT install a refrigeration unit near a heat source, nor in a location where the surrounding temperature will fall below 60º F (16º C).
Electrical Requirements
It is the customer’s responsibility to:
• Contact a qualified electrical installer.
• Assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or Canadian Electrical Code C22.1-1998 and C22.2 No. 0-M91 (or latest edition), and all local codes and ordinances.
A 115 volt, 60-Hz, 15 amp, fused, electrical supply is required. It is required that a separate circuit serving only this appliance be provided. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, grounding-type wall receptacle. DO NOT use an extension cord.
If codes permit a separate grounding wire to be used, it is recommended that a qualified electrician determine that the grounding path is adequate.
DO NOT ground to a gas line. Check with a qualified electrician if you are not sure if the appliance is properly grounded. DO NOT have a fuse in the neutral or grounding circuit.
Anti-Tip Requirements
The anti-tip boards should be fastened into position prior to moving the unit into the opening.
Note: Additional mounting boards may be required if the unit does not touch the back wall of the enclosure. To prevent unit from tipping forward, it must be secured in place with a solid soffit or wood block.
37
General Information
Water Supply Requirements
Use only 1/4” (6 mm) copper tubing for water line. DO NOT install copper tubing in area where temperatures drop below 35˚ F (1.7˚ C). Before attaching copper tubing to the unit, flush at least 2 quarts (1.9 L) of water through the copper tubing and into a bucket to remov
e any particles
in the water line.
• Viking Range, LLC is not responsible for property damage due to improper installation or water connection.
• Connect 1/4” (6 mm) flexible copper tubing to household plumbing in compliance with local codes and ordinances.
• Length of copper tubing must reach from water supply connection to the unit connection with an additional length to facilitate moving the unit out of enclosure for cleaning or service. Tubing should be soft instead of rigid and ends should be free of burrs.
• Copper tubing route must be above 35˚ F (1.7˚ C) to prevent water line from freezing.
• DO NOT use plastic water lines from the household plumbing to the water inlet valve connection on the refrigeration unit.
• DO NOT use the self-piercing feature of a saddle valve. The hole made by the piercing lance is too small for the water flow rate required by the ice maker.
• If saddle valve is not used, place a separate shut-off valve in an easily accessible location between water supply and the unit. DO NOT install shut-off valve behind the unit.
• The installation of Viking units with a reverse osmosis system is acceptable as long as the water pressure remains within the allowable PSI as stated below. It is important to note that with many reverse osmosis systems, the pressure starts off high, but then it decreases as the water level of the reverse osmosis storage area drops. This must be considered when checking the water pressure coming into the unit.
• Connect a vertical or horizontal 1/2” (1.2 cm) to 1-1/4” (3.2 cm) COLD water line near water area.
• Run water line through the floor, back, or side wall. Tubing should lay flat on floor underneath the unit. Clamp tubing to wall or floor.
• Water pressure must be greater than 20 psi and less than 120 psi on non-dispensers and greater than 35 psi and less than 120 psi on dispensers.
To avoid serious illness or death, DO NOT use unit where water is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
WARNING
38
General Information
• Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping.
• DO NOT remove protective film until unit is in operating position.
• All four leveling legs must make contact with the floor to support and stabilize the full weight.
• DO NOT drop unit.
• Remove exterior shipping materials prior to moving unit into home.
• Use two or more people to move and install unit. Failure to follow this instruction can result in back or other injury.
• To avoid personal injury, wear gloves when performing any installation procedure and wear eye protection when cutting metal straps.
Tip Over Hazard
Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions. Use two or more people to move and install the appliance. Failure to do so can result in death or serious injury.
Unpacking unit
1. Remove top and bottom strap.
2. Remove top cap.
3. Cut rear of carton approximately 1/4” (0.6 cm) to 1” (2.5 cm) from right corner with a utility knife extended 1/4” (0.6 cm).
4. Remove carton and exterior packaging. Save cardboard shipping material to protect floor surface when installing unit. Remove anti-tip board, kickplate and door trim pieces (DF models) from rear of unit.
Moving Unit
1
2
Remove shipping brackets from skid by
removing four bolts (two on each side) with a
1/2” deep-well socket wench and a pair of pliers.
Note: Tilting unit is not required to remove
shipping brackets.
Slip cart between unit and skid. Remove unit from skid.
Note: Use excess packaging to protect decorative trim;
also, verify that leveling legs are up (0” adjustment).
39
1
2
Place unit in front of cutout.
Pull the center grille louver up
at an angle and pull out.
3
4
Using an 8” magnetic nut driver,
remove the two 1/4” screws.
Remove grille assembly.
Installation
Remove four side screws and remove unit top.
Loosen the four hinge screws. Adjust door.
Retighten four hinge screws.
2
1
5
Front of unit
2
1 3
6
Hinge Adjustment
40
Replace unit top and four side screws.
Attach one 2 x 4 to wall stud (refer to dimensions page
for exact location).
If needed, depending on cabinet and depth,
attach second 2 x 4 to first 2 x 4.
1
2
7
8a
Wall
2 x 4
Refrigerator
8b
Wall
2 x 4
Refrigerator
9
Plug in power cord to verify operation.
Note: Make sure power switch and
showroom switch are in the “On” position.
3”3”3”
10a
Place unit within 3” of being flush with cabinets.
Note: To avoid cabinet damage, place cardboard
between cabinets and unit. When moving unit,
DO NOT crimp, kink or crush water supply line.
10b
Carefully move unit until semi flush with cabinet
(depending on unit).
41
11
Pull supply tubing forward under unit.
Note: DO NOT use plastic water lines.
12
13
Flush water line by running two quarts of water
into a bucket. Turn water off
Connect supply tube to water valve using
a 1/2” wrench.
Note: DO NOT overtighten.
Turn on water supply and check for leaks.
14
Lift unit off rollers to desired height
and level unit using a 5/16” head wrench.
Note: DO NOT use an electric device.
Overtightening can cause damage.
Attach positive secure self-tapping bolts
to 2 x 4 using a 22” extension.
15
Wall
2 x 4
Refrigerator
Screw
16
42
Verify that drain pan is installed and aligned.
Align holes on both ends of louvered panels
and insert screws.
Using a phillips screwdriver, attach the
kickplate to the unit and adjust to desired height.
17
1
2
18
2
1
3
19
Kickplate Installation
3
1
2
20
1
2
21
110˚
90˚
120˚
Open refrigerator door so door stop and
shoulder screw are accessible.
Note: Shoulder screw should be in 110˚ door opening position.
Remove shoulder screw and place in 90˚
or 120˚ position.
Door Stop Adjustment
43
Replace top air grille.
Using an 8” magnetic nut driver,
replace the two 1/4” screws.
Replace the center grille louver.
Open door. The display should flash.
Press “ACTIVATE CONTROLS”
pad and close door.
Note: There is a 6 minute delay before the unit starts.
28
29
30
31
32
Final Installation
44
Performance Checklist
Verify cabinet size.
Verify electrical supply and water supply
(if applicable).
Install anti-tip device(s) and verify unit is
secure.
Position unit in cutout, level at desired
height and secure unit.
Plug-in unit and verify operation.
Connect water supply (if applicable).
• Verify icemaker fill tube is properly inserted.
• Verify icemaker bail arm is down.
• Verify dispenser operation (if applicable).
Align/square door(s).
Verify drain pan is properly installed and
there are no leaks on water connection.
Install kickplate.
Remove internal packaging and labels
and wipe unit down.
Installer’s information:
Installer’s name:
_____________________________
Installer’s company:_________________________
Date: ________________________________________
45
Verify Operations
Control Panels
1. Press “Activate Controls” pad.
2. Verify unit is not in Sabbath Mode. If in Sabbath Mode: A. The Sabbath Mode will disable the interior lights, display (except SAB indicator, temperature and
compartment indicator) and alarm.
To exit the Sabbath Mode: B. Press and hold “Activate Controls” and then “Display Off” for 3 seconds.
(The control will beep three times to alert the user the Sabbath Mode has been exited.)
3. Verify unit is not in Showroom Mode. If in Showroom Mode: A. The Showroom Mode will disable the refrigerator system but all other functions are normal.
These include lights and control. (If the refrigerator is in Showroom Mode, SHOW will be lit.) To exit Showroom Mode: B. Press and hold “Activate Controls”; while holding, press and hold “Higher” and “Alarm Off”
together. (The control will beep three times to alert the user that Showroom Mode has been
exited.)
4.Press “Activate Controls” then press and hold “Lower”; while holding, press and hold “Display Off” and hold until beeps (force start compressor).
5. All models need to be set at 38° F and 0° F for the Refrigerator and Freezer respectfully - factory setting.
All Refrigerator
All Freezer
ACTIVATE
CONTROLS
REF
TEMP
HIGHER LOWER
ACTIVATE
CONTROLS
FRZ
TEMP
HIGHER LOWER
FREEZER
MAX FRZ MAX REF
FAST COOL SAB SHOW
FREEZER
MAX FRZ MAX REF
FAST COOL SAB SHOW
REFRIGERATOR
F
C
REFRIGERATOR
F
C
DOOR OPEN
POWER
HIGH TEMP
DOOR OPEN
POWER
HIGH TEMP
FAST
COOL
FAST
COOL
MAX
REF
MAX
FRZ
ALARM
OFF
ALARM
OFF
DISPLAY
OFF
DISPLAY
OFF
46
Service & Registration
If service is required, call your authorized service agency.
Have the following information readily available.
• Model number
• Serial number
• Date purchased
• Name of dealer from whom purchased
Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range, LLC at 1-888-(845-
4641), or write to:
VIKING RANGE, LLC
PREFERRED SERVICE
111 Front Street
Greenwood, Mississippi 38930 USA
Record the information indicated below. You will need it if service is ever required. The serial number and model numbers for your refrigerator are located on the upper wall, behind the lighting:
M o d e l N o .__________________________________________________ _______________________________________________________________
S e r i a l N o . ___________________________________________________________________________________________________________________
D a t e o f P u r c h a s e __________________________________________________________________________________________________________
D a t e I n s t a l l e d _____________________________________________________________________________________________________________
Dealer’s Name _____________________________________________________________________________________________________________
Address: ____________________________________________________________________________________
____________________________________________________________________________________________
If service requires installation of parts, use only authorized parts to insure protection under the warranty.
Keep this manual for future reference.
47
Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information, call 1-888-(845-4641)
or visit our web site at vikingrange.com in the US
or brigade.ca in Canada
F21344C EN
(120115)
Loading...