Viking CTG-1 User Manual

Viking's model CTG-1 is a clock controlled tone gen­erator designed to provide accurately timed bong alert tones or buzzer alert tone sounds over an existing paging system.
The CTG-1 can be programmed to output single, dou­ble or triple alert tones with up to 128 events in a 24 hour period. These bong/buzzer sounds are ideal for indicating the start and end of shifts, break times, lunch periods, etc. for factories, schools, or any busi-
Add Time Controlled Alert Tones and
Emergency Tones to Your Paging System
PPhhoonnee......771155..338866..8888661
1
hhttttpp::////wwwwww..vviikkiinnggeelleeccttrroonniiccss..ccoom
m
• Accurate 24 hour digital time clock displays hours and minutes
• User programmable 24 hour, 128 event timer
• Programmable day of week on/off feature
• Programmable single, double or triple alert
tone output (selectable bong or buzzer)
• Three contact closure controlled sounds:
1) Emergency siren (yelp) sound
2) Temporal (slow whoop) evacuation signal
*NFPA/ANSI compliant when used with supporting equipment
3) Doorbell (chime) sound
• Volume controllable, 600 ohm line level audio
output
• Non-volatile programming memory
• Battery backup for maintaining clock time with
factory installed 9V NiMh rechargeable battery
• Two sets of DPDT relay contacts for muting
paging or background music during alert tones
Power: 120V AC/13.8V AC 1.25A UL listed adapter provided Dimensions: 133mm x 91mm x 44mm (5.25” x 3.6” x 1.75”) Weight: 0.9 Kg (2 lbs) Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95%
non-condensing humidity
Connections: 12 position cage clamp terminal strip Battery Backup: 9V NiMh rechargeable battery (factory
installed) maintains clock time for over 8 hours
Time Base: 60Hz AC power line Time Base Battery Backup Accuracy: +/- 50 ppm Audio Output: 600 ohm with volume adjust potentiometer, max-
imum level = 17 dBm/5.4Vrms across 600 ohm load Relay Output: DPDT rated 125V AC, 30 W (resistive load)
PPrraaccttiicce
e
T
T
EELLEECCOOM
M
S
S
OOLLUUTTIIOONNSSFFOORRTTHHE
E
221
1
SST
T
C
C
EENNTTUURRY
Y
TECHNICAL
TECHNICAL
FFeeaattuurrees
s
SSppeecciiffiiccaattiioonns
s
ness requiring an audible indication of specified times. Each day of the week can be programmed to either on or off, allowing you to turn off the alert tones during specific days of the week (weekends, etc.)
• Signal the beginning and end of class periods, breaks, and lunch periods for schools
• Signal the beginning and end of shifts, breaks, and lunch periods for factories and other businesses
• Provides a doorbell and/or alarm sounds over an existing paging system, for such applications as door entry, fire, severe weather, etc.
• Use with Viking's DVA-2WA to provide timed messages (
Fax Back Document 110)
AApppplliiccaattiioonns
s
The CTG-1 has three contact clo­sure inputs for triggering an emergency siren, evacuation sig­nal or a doorbell sound.
CTG-1
CTG-1
Clock Controlled
Tone Generator
February 27, 2007
FFeeaattuurreessOOvveerrvviieew
w
Connect the CTG-1 between your phone system and your paging amplifier as shown in the diagram below. The factory installed rechargeable 9V battery will maintain the clock time for over 8 hours.
IMPORTANT: The CTG-1 leaves the factory with the battery backup DIP switch turned OFF to avoid discharging the battery during shipment. The battery backup DIP switch MUST be set to ON (see Programming section J) to maintain clock time during a power outage.
Clock and Event Time Setting Buttons: Press the + or -/CANCEL buttons to increase or decrease time. The -/CANCEL switch is also used to cancel an alert tone event when review­ing programming.
Alert Tones Programming Buttons: After set­ting an event time, press SINGLE, DOUBLE or TRIPLE to program 1, 2 or 3 alert bongs/buzzer sounds for that event time.
Secondary Button Functions While in the SET DAY Mode: The SINGLE button is used to select
between day (1-7) or on/off. The DOUBLE but- ton is used as a one time setup to program today’s day of the week.
12 - Common
11- Emergency Siren (Yelp): Continuous while
shorted to pin 12 (common).
10 - Evacuation Sound (Temporal Slow Whoop):
Continuous while shorted to pin 12 (common).
9 - Doorbell Chime Sound (Ding Dong): One chime per closure.
8 - N.O. 7 - COM Relay Contact 6 - N.C.
5 - N.O. 4 - COM Relay Contact 3 - N.C.
1 & 2 - 600 Ohm Audio Out Pair: Line level output,
connect to input of paging amplifier.
PM
TIME
/
CANCEL
-
+
MODE
ALERT TONES
SINGLE
DOUBLE
TRIPLE
VIKING ©
MODEL CTG-1
LOCK
SET DAY
SET TIME
SET EVENTS
REVIEW/CANCEL
CLOCK CONTROLLED
TONE GENERATOR
VOL
9V BATTERY
BACKUP
123456789101112
S1
12
on
12
ON
ON
OFF
DIP Switches: See Programming section J.
Mode Button: Press to place the CTG-1 in the
Lock, Set Time, Set Day, Set Events or Review/Cancel modes.
9V Battery Backup Connection: A standard rechargeable (NiMh) 9V battery is installed to maintain the clock time during power outages.
CTG-1 Output Volume Control: Turn clockwise to increase volume of alert bongs/buzzer sounds, emergency and door bell (chime) sounds (see diagram below).
1 2 3 4 5 6 7 8 9 10
PAGING - LOUD RINGING
AMPLIFIER SYSTEM
VIKING
ELECTRONICS
HUDSON, WI 54016
VIKING
©
MODEL PA-2A
POWER 13.8V AC
12345678910
NIGHT
TRANSFER
PAGING
HORN
600 OHM
AUDIO OUT
TRUNK OR
PAGING PORT
DRY CONTACT
CLOSURE IN
PAGING VOLUME
RINGING VOLUME
MAX
MIN
MAX
MIN
1 - 3
4 - 6
RINGING LINES
AUDIO LOADING
TALK BATTERY
ALERT TONE
WARBLE / CHIME
1 2 3 4 5
PM
TIME
/
CANCEL
-
+
MODE
ALERT TONES
SINGLE
DOUBLE
TRIPLE
VIKING ©
MODEL CTG-1
LOCK
SET DAY
SET TIME
SET EVENTS
REVIEW/CANCEL
CLOCK CONTROLLED
TONE GENERATOR
VOL
9V BATTERY
BACKUP
123456789101112
Paging port
output of
PABX/KSU
PA-2A Paging/Loud Ringing
Amplifier System
Input of
Paging Amp
-or-
Common
Siren
Evacuation Signal
Doorbell
Dry Contact Closures from Alarm Equipment, Doorbell Switch, Etc.
Display: Shows clock, event time and mode settings.
* Note: When the buzzer alert tone is programmed, a double or triple programmed event will be sounded twice, approximately three seconds apart.
IInnssttaallllaattiioon