Viewsonic VX750-1 Service Bulletin 001

ViewSonic® Corporation
381 Brea Canyon Road Walnut, CA 91789 Tel: (909) 444-8727 Fax: (909) 444-8654
To : Authorized Service Providers Issue Date: March 2, 2004 ECO # : 4022-1 Model # : VX750-1
(VLCDS27089-1W)
Subject/Symptom: Firmware update for video noise issue for QDI panel. Prepared By :
Tommy Jue
Purpose: Firmware update for video noise issue for QDI panel.
Service Bulletin Application: ASP Distribution:
Recall. - USA ASP Service Inventory, Repairs In-Process & No Problem Found (NPF). - Canada ASP Repairs In-Process & NPF. - Latin America ASP Repairs In-Process. - 3rd Party ASP Technician judgement for unit under service (symptomatic). - Supplier Service ASP
Change(s)/Countermeasure(s):
Part Location Part Description Part Number Repair Action Comment Failure
*Note: Repair action(s) that consist of the countermeasures contained in this or any other service bulletin(s), shall use D5 as the repair code. All other repair action(s) outside of the service bulletin(s) shall use the appropriate repair codes contained in the Repair and Defect Codes Handbook (i.e. C7).
Firmware chip with Rev.
0V70
Service Bulletin
Cut-in S/N: A2N035000001
S/N Range: Target Date:
Approved By :
E-IC-0450-0027
Eileen Nguyen
Replace firmware chip
with Rev. 0V60 with this
updated version.
- Limited ASP
- ViewSonic Internal
- Complete ASP Listing
For use with QDI
panel only.
Repair
Code
G0A D5
Code
Please contact the Quality Assurance Department at (909) 444-8727 for further informati on.
4.19: Form, Service Bulletin 10/30/2002
SERV-BULL-V1 Page 1 of 1
Loading...