Vetter Pneum. collection containers User Manual

Page 1
Emergency Pneumatics.
Operating Instructions
Vetter Pneumatic Hazmat Container PAB
Article No. 9987007202 | © Vetter GmbH I 09/14 I Changes and errors excepted.
Page 2
Vetter Pneumatic Hazmat Container PAB
Contents
1. Important preliminary remarks ....................................2
2.1 Inventory check ............................................2
2.2 Area of application ..........................................2
2.3 Safety instructions .........................................2
2.4 Correct handling and usage .................................3
3.1 Preparations for operation ..................................3
4.1 Operation with compressed air ..............................3
4.2 Pumping o the collected uid ..............................3
4.3 Deation ...................................................4
4.4 Care and Maintenance ......................................4
5. Inspection ........................................................5
6. Taking the product out of operation ...............................5
7. Technical data ....................................................5
Page 1/6
Page 3
1. Important preliminary remarks
Only an understanding and exact observance of this operating manual can guarantee correct and perfect operation, achieve the greatest possible use and meet the requirements contained wi­thin the scope of the Vetter guarantee.
Every application/operation of the Hazmat Container PAB requires an exact understanding and adherence to these operating inst­ructions.
The operating instructions given here are to be regarded as part of the product and are to be kept for the complete life duration of the product. In case the product should be passed on to a succes­sive user then the operating instructions must also be included.
2. Description of the product
2.1 Inventory check
Article No. Description
1510000302 Pneumatic stiening frame x
1510004301 Pneumatic stiening frame x
1510000200
1510004600
1600026100 Pressure regulator 200/300 bar/4500 psi x x
3110000700 Valise (110 x 72 x 30 cm/43 x 28 x 12 inch) x
1520004200 Valise (110 x 85 x 40 cm/ 43 x 33 x 16 inch) x
0050004500 Set repair material x x
Special exitank 3000 l/106 cu.ft., PVC-
coated on both sides
Special exitank 5000 l/1077 cu.ft., PVC-
coated on both sides
PAB
3000
x
PAB
5000
x
2.2 Area of application
Contaminated extinguishing water, chemicals, oil and dirty water must be quickly collected and temporarily stored in cases of re, oods, storms, pipe bursts and accidents.
To do this, the Vetter Pneumatic Hazmat Container is now availab­le.
2.3 Safety instructions
All relevant national regulations regarding work safety and acci­dent prevention are to be just as equally observed as those regu­lations generally recognized in the engineering eld. Work pro­tection clothing is to be worn during operational conditions.
Page 2/6
Page 4
Vetter Pneumatic Hazmat Container PAB
2.4 Correct handling and usage
The Pneumatic Hazmat Container PAB is only allowed to be used with compressed air. Only original Vetter ination ttings are to be used in order to avoid over-ination of the Hazmat Container.
3. Preparing the product for use
3.1 Preparations for operation
Only perfectly working Hazmat Containers are to be used having original Vetter ination ttings. Before being used, the chemical resistance of the PVC foldable container is to be tested against the liquid or substance to be collected.
4. Operating instructions
Open the packing cover. Lay out the Pneumatic Hazmat Contai-
5
1
2
3
ner at the required location. The ground area must be free of any sharp-edged or pointed objects!
4.1 Operation with compressed air
4
6
7
Connect the pressure regulator with the knurled wheel on the compressed air bottle. Close the hand wheel (3) of the pressure regulator. Open the valve on the bottle (5). The manometer (1) indicates the pressure in the bottle. Adjust the back-pressure to approximately 10 bar/145 psi using the adjustment wheel (4). The set pressure can be checked on the back-pressure manometer (2). Connect the air hose of the pressure regulator (6) with the brass coupling (7) of the ination connection. Open the pressure regu­lator and start ination. Observe the Pneumatic Hazmat Container during the ination process. Close the hand valve when the ope­rating pressure of 0.5 bar/7.25 psi is reached.
The Vetter Pneumatic Hazmat Container is now operati-
onal.
Do not inate outer frame! The valve is only for air compensation when the container is upright or folded.
Page 3/6
4.2 Pumping o the collected uid
To pump o the collected uid, use a commercially availab­le immersion pump (comply with the resistance), e.g. item no.: 1520041600 dewatering pump. For complete vacuum withdra­wal, if necessary the suction nozzle (Item no.: 1700014701) can be used in combination with a Vetter aspirator.
Page 5
4.3 Deation
The deation of the Pneumatic Hazmat Container happens over the ination connection. To deate the Pneumatic Hazmat Contai­ner, close the compressed air cylinder and disconnect the pressure reducer. Screw the cap o of the lling connection in the counter­clockwise direction. The deation valve is opened by pressing-in and turning the pin (1) counter clockwise.
1
Pin before locking Pressing-in + turning Valve open
Fold the Pneumatic Hazmat Container s in the way, that the air can escape (Folding to the direction of the ination connection). Any remaining air can be removed with a vacuum adaptor (Item No.:
1700018300) in combination with an construction-site compres­sor adaptor (Item No.: 1600012000).
1
Connect the construction-site compressor adaptor (1) to the cou­pling of the vacuum adaptor (2) and turn it interlocking. Then tighten the screwable part of t the vacuum adaptor. Now connect the constructionsite compressor adaptor to the pneumatic stie­ning frame. Attach the quick-action coupling (3) to the connec­tion hose of the pressure regulator (pressure approx. 6 bar/87 psi) and open the hand valve of the pressure regulator slowly. Using the vacuum adapter the air is sucked out of the Hazmat container which can then be quickly packed without diculty.
2
3
After deation and before packing, the valve must be unlocked again in order to guarantee perfect ination when it is next used!
4.4 Care and Maintenance
The Hazmat Container and its ttings are to be cleaned after use. Cleaning of the Hazmat Container is normally made using warm water together with a soap solution and dried at room tempera­ture. DIN 7716 is to be observed when storing for long periods of time.
Page 4/6
Page 6
Vetter Pneumatic Hazmat Container PAB
5. Inspection
The ination ttings and the Hazmat Container are to be checked for a perfect and orderly condition each time before and after use:
9 The stiening frame is free of damage, e.g. tears, cuts, pier-
cings, splits, hard or soft areas caused by chemical or thermal eects.
9 The PVC foldable container is free of damage, e.g. tears, cuts,
piercings, splits, hard or soft areas caused by chemical or ther­mal eects.
9 Visual and operational check of the pressure regulator
6. Taking the product out of operation
In case the Pneumatic Hazmat Containers are taken out of ope­ration then this must be disposed of as special waste. If required, the manufacturer can supply you with more detailed information regarding this.
7. Technical data
Type PAB 3000 PAB 5000
Art.-No. (set)
cm 225 280
Size (internal) Ø
inch 88 11 0
cm 265 320
Size (external) Ø
inch 104 126
cm 95 95
Height
inch 37 37
bar 0.5 0.5
Operating pressure
psi 7.25 7.25
bar 0.65 0.65
Test pressure
psi 9.4 9.4
l 470 562
Nominal content
cu.ft. 16.6 19.8
l 705 843
Air requirement
cu.ft. 25 30
1510000101 1510004001
Page 5/6
Capacity
l 3,000 5,000
cu.ft. 106 177
kg 33 44
Weight
lbs 73 97
All rights reserved for technical changes within the scope of product improve­ment.
Page 7
Place your trust in emergency pneumatics!
We are the company who can help you, nd a solution to your problem!
Vetter GmbH
A Unit of IDEX Corporation
Sales
Blatzheimer Str. 10 - 12 D-53909 Zülpich Germany
www.vetter.de
Tel.: +49 (0) 22 52 / 30 08-0 Fax: +49 (0) 22 52 / 30 08-590 Mail: vetter.rescue@idexcorp.com
Article No. 9987007202 | © Vetter GmbH I 09/14 I Changes and errors excepted. | Made in Germany