Page 1
Emergency Pneumatics.
Operating Instructions
VETTER Pneumatic Decon Tents
Article No. 9987018005 | © Vetter GmbH I 09/14 I Changes and errors excepted.
Page 2
Vetter Pneumatic Decon Tents
Contents
1. Important preliminary remarks ....................................2
2.1 Scope of delivery ...........................................2
2.2 Optional accessories ........................................3
2.3 Correct handling and usage .................................3
2.4 Safety instructions ..........................................3
3.1 Preparations for operation ..................................3
4.1 Operation with blower ......................................4
4.2 Operation with compressed air ..............................4
4.3 Use as decontamination tent ................................5
4.4 Instructions of the showers .................................6
4.5 Deation ...................................................7
4.6 Folding Plan ................................................8
5. Practical Tips ......................................................9
6. Repeated Inspections .............................................9
7. Repair Instructions ................................................9
8. Technical data ..................................................10
Page 1/11
Page 3
1. Important preliminary remarks
These instructions must be read carefully and complied with at all times to ensure this product is used properly and as intended, to ensure this product provides the greatest possible benet, and that the entitlements within the scope of the Vetter warranty are preserved.
Each use/operation of the pneumatic universal tent requires detailed knowledge and compliance of these inst­ructions.
The operating instructions given here are to be regarded as part of the product and are to be kept for the comple­te life duration of the product. In case the product should be passed on to a successive user then the operating instructions must also be included
2. Description of the product
2.1 Scope of delivery
Article No. Description PZ 17 Decon 2 L
(1520047000)
1520034500 Tent frame PZ 40 3 L incl. tension rope X
1520046600 Tent frame PZ 17 Decon 2 L X
1520034600 Tent oor PZ 40 3 L X
1520046400 Tent oor PZ 17 Decon 2 L X
1520034800 Tent cover PZ 40 3 L X
1520046800 Tent cover PZ 17 Decon 2 L X
1520034900 2 x Entry covers type PZ 40 3 L with 3 doors X
1520046900 2 x Entry covers type PZ 17 Decon 2 L with 2 doors X
1520035000 2 x Separation wall, longitudinal PZ 40 3 L X
1520046500 Separation wall for PZ 17 Decon 2 L X
1520034700 Collection tub for PZ 40 3 L X
1520046300 Collection tub for PZ 17 Decon 2 L X
1520035300 Shower hose PZ 40 3 L X
1520046700 Shower hose PZ 17 Decon 2 L X
1520035100 Shower cover type PZ 40 3 L left/right X
1520035200 Shower cover type PZ 40 3 L centre X
PZ 40 3 L
(1520035500)
1520031100 2 x Shower cover type PZ 17 Decon 2 L X
1510014700 Decon hand shower 4 X 12 X
1520000500 Packing bag (110 x 85 x 60 cm) X
1520011500 Packing bag (110 x 85 x 85 cm) X
1520002400 18 x Square earthing pins X
1520033500 24 x iron tent pegs, 30 cm X
1520028301 Repair material X X
1520002500 Bag, red, for tent pegs X
1523013900 Bag, red, for tent pegs X
1523006800 Hammer X X
Page 2/11
Page 4
Vetter Pneumatic Decon Tents
2.2 Optional accessories
Article No. Description
1523003700 Valise for PZ 17 Decon 2 L, 265 x 150 cm (104 x 59 inch), yellow, Incl. auto belt latch
1523013300 Valise for PZ 40 3 L, 330 x 160 cm (130 x 63 inch), yellow, incl. auto belt latch
2.3 Correct handling and usage
Always use compressed air with the pneumatic decon tents - ever use ammable or aggressive ga­ses. Only Vetter original ttings and parts may be used for the pneumatic decon tents.
2.4 Safety instructions
Only trained, reliable, and responsible employees are permitted to use and operate this product. Wear the required protective gear and clothing. Please contact the manufacturer or authorized re­tailer when detecting cracks, ssures, holes, or leakages on the pneumatic supporting frame during the product inspection. Such defects can lead to bursting. Always avoid contact with hot or sharp­edged materials.
Due to the light design of the pneumatic tents, it is possible that heavy winds may cause stability problems.
Always fasten tents with anchoring ropes or use ballast containers. Comply with DIN 7716 if storing the pneumatic universal tents long-term.
3. Preparing the product for use
3.1 Preparations for operation
Inspect the pneumatic decon tent before and after each operation to ensure correct and perfect condition. It is imperative that the recommended folding instructions be observed.
Page 3/11
Page 5
4. Operating Instructions
Open the packing cover. Lay out the tent at the required location. The ground area must be free of any sharp-edged or pointed ob­jects! The decon tents are designed to be inated with a blower or with compressed air.
4.1 Operation with blower
The ination connection for blowers is opened when air ows through. Connect the ination hose of the blower to the ination connection of the tent. Unscrew the cap from the ination con­nection in a counter-clockwise direction and check whether the valve is closed. Make certain there is perfect locking of the coup­lings of the ination hose with the tent coupling and the blower.
Start the blower and ll the tent until the maximum permitted operating pressure. The medical tent erects automatically. The sa­fety valve integrated into the support frame avoids over-ination.
Note! Should parts of the support frame become caught up during erection then switch o the blower immediately and rectify the problem. Ination can then be continued after doing this.
e.g. Tent blower 0.23-0.47 bar (Art. no. 1523017700)
Replace the cap after lling and tighten it by turning it in a clock­wise direction.
4.2 Operation with compressed air
Connect the pressure regulator with the knurled wheel on the compressed air bottle. Close the hand wheel (3) of the pressure regulator. Open the valve on the bottle (5). The manometer (1) indicates the pressure in the bottle. Adjust the back-pressure to approximately 10 bar using the adjustment wheel (4). The set pressure can be checked on the back-pressure manometer (2). Connect the air hose of the pressure regulator (6) with the brass coupling (7) of the ination connection. Open the pressure regu­lator and start ination. Observe the shower during the ination process. Close the hand valve when the max. operating pressure is reached.
Attention!
9 With the PZ 17 Decon 2 L you must ensure that the connec-
tion hose is correctly connected between the tent frame and the shower tub
Note! If, during erection of the tent, parts of the tent frame become caught up in the tent cover, then close the valve on the pressure regulator immediately and rectify the cause of the problem. After doing this, the ination process can be continued.
1
5
2
3
6
4
7
Page 4/11
Page 6
Vetter Pneumatic Decon Tents
4.3 Use as decontamination tent
The water connection for the shower heads and the hand showers is po­sitioned in the blue throughway opening and is a Storz Coupling Size D for water. The lling connection is positioned in the green throughway opening. Therefore this makes any confusion impossible with respect to the connections.
PZ 17 Decon 2 L:
The tent is subdivided by 1 longitudinal partition into two lines. There are two each doors in the entrance awnings to enable entering the lines separately. The two shower units in the middle of the tent divide the tent into the undressing, showering and dressing areas. The continuous collecting basin prevents uid from transgressing into the rest of the tent. The showers with the shower cap create a self-contained unit. 2
1
each shower handsets (1) in the individual shower units provide optimal cleaning of the contaminated person.
PZ 40 3 L:
The tent is divided into three lines using two longitudinal separation walls. There are three doors in the entry covers in order to separately enter each of the lines. The three shower units in the centre of the tent divide the tent into three areas: clothe removal area, shower area and the dressing area. Continuous shower tubs stop any liquid overow into the remaining area of the tent. The showers with the shower covers form an enclosed unit. Four hand showers (1) in the individual shower units ensure optimum decontamination of contaminated persons.
Page 5/11
Page 7
Vetter PZ 17 Decon 2 L
The Vetter decontamination path (PZ 40 3 L)
4.4 Instructions of the showers
The required amount of water can be regulated via the ball valve (1).
In order to change the shower curtains the hand showers (2) must rstly be uncoupled and the rubber washers (3) removed. The shower curtain can now be removed by separating the Vel­cro and pile fabric connections on the vertical support hose and unhooking the eyelets (4) on the insertion basin.
3
4
2
1
2
Page 6/11
Page 8
Vetter Pneumatic Decon Tents
1
2
3
4.5 Deation
The deation of the support frame happens over the ination connec­tion. To deate the tent, close the air source (compressed air cylinder, etc.) and disconnect the pressure reducer or the lling hose of the blo­wer. The deation valve is opened by pressing-in and turning the pin (1) counter clockwise.
1
Pin before locking Pressing-in + turning Valve open
Fold the tent in the way, that the air can escape (Folding to the direction of the ination connection). Any remaining air can be removed with a vacuum adaptor (Item No.: 1700018300) in combination with an const­ruction-site compressor adaptor (Item No.: 1600012000).
Connect the construction-site compressor adaptor (1) to the coupling of the vacuum adaptor (2) and turn it interlocking. Then tighten the screwable part of t the vacuum adaptor. Now connect the construction­site compressor adaptor to the support frame. Attach the quick-action coupling (3) to the connection hose of the pressure regulator and open the hand valve of the pressure regulator slowly.
It is also possible to deate the support frame with a blower with deate function. Follow the operating instructions of the blower.
After deation and before packing, the valve must be unlocked again in order to guarantee perfect ination when it is next used!
Page 7/11
Page 9
4.6 Folding Plan
Bef üllanschlus
Before repacking, the tent frame and the frame of the shower must be completely empty.
1. The front of the tent is folded lengthwise in four equal sections.
L
Ination connector
Stirnseite
Front
2. Then fold the tent ve times in the direction of the ination connector.
3. Now place the tent into the carrying bag.
Page 8/11
Page 10
Vetter Pneumatic Decon Tents
5. Practical Tips
9 The individual separating walls, oor tarps, as well as the tent
tarpaulins are removed easily and quickly if and as needed. Hook and loop fasteners are used to attach the tarpaulin to the pneumatic supporting frame.
9 When using tent heaters, avoid blowing heat directly onto
parts of the tent.
9 If needed, lights can be suspended from the supporting frame.
9 Additional tents are easily connected using hook and loop
overlaps.
9 After use, clean the tent with a mild cleanser before packing.
Allow the parts to dry at normal room temperature. Treat outer surfaces with commercially available impregnating agents.
9 Follow the instructions of the folding plan to fold and pack
the tent. Make sure that the tent is folded and packed in an orderly manner and as instructed to ensure the tent is easy to unpack next time it is needed.
6. Repeated Inspections
The tents should be subjected to a visual and functional inspec­tion by a trained technician at least once a year. This requires ina­ting the tent to approx. 50 % of the max. working pressure (0.25 bar). Check all pressurized parts for ssures, cracks, cuts, puncture holes, detached spots, and heat or chemical damage. If the pres­sure does not experience a signicant drop within one hour, the tent is ready for use.
Please contact the manufacturer in case of larger damage or if you have any questions. Comply with DIN 7716 if storing the pneuma­tic universal tents long-term.
7. Repair Instructions
Minor damage such as cracks, cuts, or punctures (max. 4 cm) can be repaired by the operator with the enclosed repair kit. Please follow these steps:
1. Select the size of the patch so that the patch extends approx. 4 cm beyond the damaged area on all sides.
2. Mark patch area on the supporting frame.
Page 9/11
3. Roughen the area of the patch on the surface of the sup­porting frame as well as one side of the patch.
4. Apply a thin layer of the special adhesive to the roughened spot on the supporting frame and the roughened side of the patch.
5. Allow special adhesive to dry for approx. 10-15 minutes until no longer sticky.
Page 11
6. Press patch rmly onto the pretreated area of the supporting frame and smooth out.
7. Allow unpressurized supporting frame to rest for at least 48 hours.
Only the factory is able to repair damage that is more ex­tensive.
A trained technician must check the tent and its supporting frame for leaks after the repairs.
8. Technical data
Type
Article No. (Set) 1520047000 1520035500
m 4.9 x 3.86 x 2.48 8 x 5.5 x 3.1
Size outside (L x W x H)
ft. 16 x 13 x 8 26 x 18 x 10
m 4.9 x 3.5 x 2.3 8 x 5.1 x 2.9
Size inside (L x W x H)
ft. 16 x 12 x 8 26 x 16 x 9
bar 0.5 0.5
Working pressure
psi 7.25 7.25
bar 0.65 0.65
Test pressure
psi 9.4 9.4
l 1,776 4,576
Nominal capacity
cu. ft. 62.72 161.6
l 2,664 6,863
Air requirement
cu. ft. 94.1 242
Ination time ca. sec 60 300
m 1.1 x 0.85 x 0.6 1.1 x 0.85 x 0.85
Pack size (L x W x H)
ft. 3 x 2 x 1 3 x 2 x 2
PZ 17 Decon 2 L
PZ 40 3 L *
Weight
kg 105 204
lbs 231 450
* Also available as a 40 m² tent with 2 lines. PZ 40 2 L (1520048900) All rights reserved for technical changes within the scope of product improvement.
Page 10/11
Page 12
Place your trust in emergency pneumatics!
We are the company who can help you, nd a solution to your problem!
Vetter GmbH
A Unit of IDEX Corporation
Sales
Blatzheimer Str. 10 - 12 D-53909 Zülpich Germany
www.vetter.de
Tel.: +49 (0) 22 52 / 30 08-0 Fax: +49 (0) 22 52 / 30 08-590 Mail: vetter.rescue@idexcorp.com
Article No. 9987018005 | © Vetter GmbH I 09/14 I Changes and errors excepted. | Made in Germany