Vetter Compact shower User Manual

Page 1
Emergency Pneumatics.
Operating Instructions
VETTER Decon Showers 0.3 bar/4.35 psi
Compact ShowerDecon Shower
Article No. 9987040203 | © Vetter GmbH I 09/14 I Changes and errors excepted.
Page 2
Vetter Decon Showers 0.3 bar/4.35 psi
Contents
2. Description of the product ........................................2
2.1 Inventory check ............................................2
2.2 Correct handling and usage .................................2
2.3 Safety instructions ..........................................2
3. Operating Instructions ............................................3
3.1 Operation with blower ......................................3
3.2 Operation with compressed air ..............................3
3.3 Handling of the shower .....................................4
3.4 Deation and Packing ......................................4
4. Care and Maintenance ............................................5
Page 1/7
Page 3
1. Important preliminary remarks
Only an understanding and exact observance of this operating manual can guarantee correct and perfect operation, achieve the greatest possible use and meet the requirements contained wi­thin the scope of the Vetter guarantee.
Every application/operation of the Decon Showers 0.3 bar re­quires an exact understanding and adherence to these operating instructions.
The operating instructions given here are to be regarded as part of the product and are to be kept for the complete life duration of the product. In case the product should be passed on to a succes­sive user then the operating instructions must also be included.
2. Description of the product
2.1 Inventory check
Description Qty.
Set, consisting of:
Support frame 1
Insertion basin 1
Shower hose 1
Shower curtain 1
Repair material 1
Packing bag 110 x 72 x 30 cm/42.9 x 28.1 x 11.7 inch 1
2.2 Correct handling and usage
The Decon Showers 0.3 bar are to be used for decontamination of persons and are only allowed to be used with compressed air. Only original Vetter ination ttings are to be used in order to avoid over-ination of the Decon Shower´s pneumatic supporting frame.
2.3 Safety instructions
All relevant national regulations regarding work safety and acci­dent prevention are to be just as equally observed as those regu­lations generally recognized in the engineering eld. Work pro­tection clothing is to be worn during operational conditions.
Page 2/7
Page 4
Vetter Decon Showers 0.3 bar/4.35 psi
3. Operating Instructions
Open the packing cover. Lay out the shower at the required loca­tion. The ground area must be free of any sharp-edged or pointed objects!
The pneumatic 0.3 bar Decon showers are designed to be inated with a blower or with compressed air.
3.1 Operation with blower
eg. Tent blower 0.23-0.47 bar (Art. no. 1523017700)
The ination connection for blowers is opened when air ows through. Connect the ination hose of the blower to the ination connection of the shower. Make certain there is perfect locking of the couplings of the ination hose with the shower coupling and the blower.
Start the blower and ll the shower until the maximum permitted operating pressure of 0.3 bar/4.35 psi. The decon shower erects automatically. The safety valve integrated into the support frame avoids over-ination (greater than 0.3 bar/4.35 psi).
Note! Should parts of the support frame become caught up during erection then switch o the blower immediately and rectify the problem. Ination can then be continued after doing this.
3.2 Operation with compressed air
1
5
2
3
6
4
7
Connect the pressure regulator with the knurled wheel on the compressed air bottle. Close the hand wheel (3) of the pressure regulator. Open the valve on the bottle (5). The manometer (1) in­dicates the pressure in the bottle. Adjust the back-pressure to ap­proximately 10 bar using the adjustment wheel (4). The set pres­sure can be checked on the back-pressure manometer (2).
Connect the air hose of the pressure regulator (6) with the brass coupling (7) of the ination connection.
Open the pressure regulator and start ination. Observe the shower during the ination process. Close the hand valve when the operating pressure of 0.3 bar/4.35 psi is reached.
The decon shower erects automatically. The safety valve integra­ted into the support frame avoids over-ination (greater than 0.3 bar/4.35 psi).
Page 3/7
Note! Should parts of the support frame become caught up during erection then close the valve of the pressure regulator immediately and rectify the problem. Ination can then be continued after doing this.
Page 5
3.3 Handling of the shower
max. water temperature: 45° C
max. water pressure: 10 bar/145 psi
The required amount of water for the 8 shower jets (1) attached to the support frame can be regulated via the ball valve (2). The shower jets can be swivelled within the plastic holder ring.
Turn the grey securing ring counter-clockwise in order to change the shower curtain. Remove the shower nozzle together with the O-ring seal and replace the shower curtain by separating the Vel­cro and pile fabric connection on the vertical support hose and unhooking the eyelets (5) on the insertion basin. The assembly happens in reversed order.
There is a quick-snap coupling in the upper area of the show­er hood which additionally enables connection of a hand wash brush (4). For this purpose push the connecting nipple into the self-locking quick-snap coupling (3), until it locks perceptible.
3.4 Deation and Packing
The deation of the support frame happens over the ination connection. To deate the tent, close the air source (compressed air cylinder, etc.) and disconnect the pressure reducer or the lling hose of the blower. The deation valve is opened by pressing-in and turning the pin (1) counter clockwise.
1
2
3
4
1
Pin before locking Pressing-in + turning Valve open
Fold the shower in the way, that the air can escape (Folding to the direction of the ination connection).
Any remaining air can be removed with a vacuum adaptor (Item No.: 1700018300) in combination with an construction-site com­pressor adaptor (Item No.: 1600012000).
1
2
Connect the construction-site compressor adaptor (1) to the cou­pling of the vacuum adaptor (2) and turn it interlocking. Then tighten the screwable part of t the vacuum adaptor.
3
3
4
5
Page 4/7
Page 6
Vetter Decon Showers 0.3 bar/4.35 psi
Now connect the constructionsite compressor adaptor to the sup­port frame. Attach the quick-action coupling (3) to the connection hose of the pressure regulator and open the hand valve of the pressure regulator slowly.
It is also possible to deate the support frame with a blower with deate function. Follow the operating instructions of the blower.
After deation and before packing, the valve must be unlocked again in order to guarantee perfect ination when it is next used!
4. Care and Maintenance
The Decon Showers 0.3 bar and its equipment is to be cleaned after use. Cleaning of the Decon Showers is normally carried out with warm water with a soap solution and then dried at room temperature. Cleaning with high pressure hot water devices must not be carried out under any circumstances. If necessary, conta­minated showers are to be decontaminated with suitable disin­fection agents. DIN 7716 is to be observed when storing for long periods of time
5. Test
The ination ttings and the Decon Showers 0.3 bar are to be che­cked for a perfect and orderly condition each time before and af­ter use:
9 The parts of the stiening frame are free of damage, e.g. tears,
cuts, piercings, splits, hard or soft areas caused by chemical or thermal eects.
9 The PVC foldable container is free of damage, e.g. tears, cuts,
piercings, splits, hard or soft areas caused by chemical or ther­mal eects.
9 Visual and operational check of the ination connection and
the blower including the accessories.
Page 5/7
Page 7
6. Technical data
Type
Article No.
Article No. (with gloves and drain)
Erection time, ca.
Ext. basin size (L x W x H)
Int. basin size (L x W x H)
Total height
Air requirement
Capacity
Ø Water ow rate
Pack size
Weight, ca.
sec.
cm
ft
cm
ft
cm
ft
l
cu.ft.
l
cu.ft.
l/min.
cu.ft./min.
cm
inch
kg
lbs
Compact shower Decon shower
1513000102 1513003900
1513003700 1513001801
30 40
156 x 156 x 20 276 x 156 x 20
5 x 5 x 0.65 9 x 5 x 0.65
120 x 120 x 20 240 x 120 x 20
4 x 4 x 0.65 8 x 4 x 0.65
220 220
7 7
682 738
24 26
300 770
11 27
25 25
0.88 0.88
110 x 72 x 30 110 x 72 x 30
43 x 28 x 12 43 x 28 x 12
24-29 27-32
53-64 60-71
All rights reserved for technical changes within the scope of product improvement.
Page 6/7
Page 8
Place your trust in emergency pneumatics!
We are the company who can help you, nd a solution to your problem!
Vetter GmbH
A Unit of IDEX Corporation
Sales
Blatzheimer Str. 10 - 12 D-53909 Zülpich Germany
www.vetter.de
Tel.: +49 (0) 22 52 / 30 08-0 Fax: +49 (0) 22 52 / 30 08-590 Mail: vetter.rescue@idexcorp.com
Article No. 9987040203 | © Vetter GmbH I 09/14 I Changes and errors excepted. | Made in Germany
Loading...