Thank you for purchasing your new fridge/ freezer from Vestfrost. Please note that these instructions apply to all fridge/freezers in the FZ range. Illustrations and fi ttings may therefore not necessarily correspond exactly to your model.
Warning
As the refrigerant used in this appliance is a fl ammable gas (Isobutane R600a), special care must be taken to prevent damage to the refrigerant circuit and piping during transport and installation.
If damage does occur, avoid sparks or naked fl ame in the vicinity of the appliance, ensure that the room is well ventilated, disconnect the power supply, and contact your supplier.
The unit must only be serviced by qualifi ed technicians from an approved service centre.
Old appliances
Old refrigerators and freezers are often fi tted with complicated latches that can only be opened from the outside. If you have one of these old units stored away somewhere, or if you scrap one, remember to destroy the latch fi rst in order to prevent children from being exposed to danger by getting locked inside the unit.
Disposal
This appliance contains recyclable materials. Before disposing of the unit, detach the plug from the cable and remove the doors. If the doors are left on, the appliance is highly dangerous for children at play.
Environmental regulations on disposal must also be observed. When disposing of the appliance you should contact your local
authority technical department who will inform you of how collection and recycling of such units take place in your area.
Before use
Before operating your new appliance, please read the following instructions carefully as they contain important information on safe installation, operation and maintenance. Keep the instructions for future reference.
On receipt, check to ensure that the appliance has not been damaged during transport. Transport damage should be reported to the local distributor before the appliance is put to use.
Remove the packaging. Clean the inside of the cabinet using warm water with a mild detergent. Rinse with clean water and dry thoroughly (see cleaning instructions). Use a soft cloth.
If during transport the appliance has been laid down, or if it has been stored in cold surroundings (colder than +5°C), it must be allowed to stabilise in an upright position for at least an hour before being switched on.
Contents
Get to know your fridge/freezer.........3
Installation and start-up.....................4
Electrical connection.........................6
Reversing the doors..........................7
Operation and function......................8
Refrigerator section.........................11
Freezer section...............................12
Cleaning and maintenance.............14
Fault fi nding....................................15
Warranty, spare parts and service..16
3
DB
Get to know your fridge/freezer
fi g. 1
Control panel
Lighting
Shelf with storage boxes
Door shelf
Bottle rack
Large storage box
Glass shelf
Nameplate
Crisper bins
Freezing tray
Sealing strip
Freezer drawers
Door handle
Defrost water drain
Kick plate
Adjustable feet
4
GB
Placement
For safety and operational reasons, the appliance must not be installed outdoors.
The appliance should be placed on a level surface in a dry, well ventilated room (max. 75% relative air humidity). Never place the appliance close to sources of heat such as cookers or radiators, and avoid placing it in direct sunlight.
Room temperature
The climate class is stated on the nameplate (see fi g. 1 on page 3 and fi g. 17 on page 13). This specifi es the optimum room temperature.
Climate class Optimum room
temperature
SN +10 ºC to +32 ºC
N +16 ºC to +32 ºC
ST +18 ºC to +38 ºC
T +18 ºC to +43 ºC
Installation
The surface on which the appliance is to be placed must be level. Do not use a frame or similar.
The appliance can be installed as a free­standing unit against a wall, built into a kitchen element, or lined up with other appliances (fi gs 2 and 3).
600
600
fi g. 2
fi g . 3
Installation and start-up
5
DB
Ventilation
It is important that the appliance be well ventilated and that air can circulate unhindered above, below and around it. The fi gures below illustrate how the necessary air circulation can be ensured (fi gs 6 and
7). If two fridge/freezers are placed side by side, there must be at least 30 mm clearance between them.
1650/1950
100
100
1560/1860
fi g. 6
fi g. 7
The appliance viewed from above
If the appliance is placed beside a wall, there must be suffi cient room for the freezer door to be opened wide enough to allow the drawers to be pulled out (fi g. 4).
600
610
fi g . 4
Fitting the tilt-stop
A tilt-stop can be fi tted to prevent the unit from tilting forwards when the door is opened. Mount the tilt-stop on the wall behind the appliance 80-100 mm from the left or right side of the appliance depending on the side on which the door is hinged. The tilt-stop must always be fi tted on the side opposite to the hinge (fi g. 5).
80 - 100 mm
fi g. 5