H280 SERIES
VERIS INDUSTRIES
Load Status Switch
Provides Status For
Manually Switched Loads
DESCRIPTION
The H280 load status switch monitors both voltage and current on manuallyswitched loads (e.g., lights/fans in bathrooms). This device provides status
monitoring for loads that are not, or cannot be, controlled by a control system.
The H280 also saves cost by eliminating the need to connect a digital output to
prove status.
APPLICATIONS
● Lighting
● Bathroom Fans
● Sump Pumps
● Trac Lights
● Roadside Lighted Areas (e.g., bus stations)
current monitoring
● Parking Lots/Garages
TM
H280
FEATURES
● Wide voltage range (110-277VAC)...easy to use in many applications
● Low current threshold (100mA) oers great sensitivity for those small loads
● Nipple mount housing can be connected to any 1/2” conduit knockout for
installation versatility
● Dual-color LED for easy visual inspection...control system is not required
● Isolated status output protects control system
Year
5
SPECIFICATIONS
Sensor Power Line powered
Operating Temperature -15° to 60°C (5° to 140°F)
Operating Humidity 10-90% RH noncondensing
LED Status GREEN LED=status normal; RED LED=status alarm
Frequency 50/60 H z
Wire Specications:
Lead Length 14” (356 mm) min.
Gauge UL1015; Neutral: 18 AWG; Line: 12 AWG; Status: 16 AWG
Agency Approvals UL 508 open device listing
Do not use the LED status indicators as evidence of applied voltage.
800.354.8556
Warranty
+1 503.598.4564
www.veris.com
HQ00 01773.B 01131
800.354.8556
Current
Switch
Voltage
Switch
Output
Neutral
ORANGE
White
ORANGE
yel
l
ow
yel
l
ow
From Line
To Load
Current Flow
110-277VAC
+1 503.598.4564
www.veris.com
DIMENSIONAL DRAWING
(74 mm)
2.8"
(71 mm)
1/2" NPT Nipple
WIRE COLOR CODES
Line Connections
1.7"
(43 mm)
1.6"
(41 mm)
1.8"
(46 mm)
APPLICATION/WIRING DIAGRAM
Nipple mount to 4x electrical box
Status Output
(Grey) or (Brown)
POWER
SOURCE
NOTE: Incidental loads as small as 30mA AC, such as pilot lamps or control circuits, connected in parallel to the
sensed load may draw enough current to give a false load presence signal, even though the true load has been
interrupted.
HOW IT WORKS
VOLTAGE CURRENT H280 H280NC LED
ON ON OPEN CLOSED GREEN
ON OFF CLOSED OPEN RED
OFF OFF OPEN CLOSED OFF
Line
Neutral
Switch
Orange Orange
Wht/Yellow
STATUS O UTPU T
Status Outputs
H280 (NO)
GREY
COMMON
GREY
N.O.
ORDERING INFORMATION
MODEL AMPERAGE RANGE VOLTAGE RANGE STATUS OUTPUT
H280
H280NC N.C. 100mA@120VAC/DC
HQ00 01773.B 01131
0.1 - 20A 110 - 277VAC
N.O. 100mA@120VAC/DC
H280 NC
BROWN
COMMON
BROWN
N.C.
(max.)
TRIP POINT HOUSING STATUS
LED
0.1A or less
Nipple Mount
n n n
n n n
RELAY
POWER LED
current monitoring
UL