Veris FSR Datasheet

FST & FSRSERIES
Ultrasonic Flow and
VERIS INDUSTRIES
FSR Monitor
FST4, FST5 Transduce r
Energy BTU Meter
Accurate Readings From Outside the Pipe
DESCRIPTION
The monitor is available in two versions: standard ow and energy ow versions. Energy versions are used in conjunction with dual clamp-on or insert RTD temperature sensors. The energy ow meter calculates energy usage in BTU or tons, and it is ideal for retrot, chilled water, and other HVAC and building automation applications.
APPLICATIONS
Commercial and industrial installations involving clean liquids or liquids
containing small amounts of suspended solids or aeration
Temperature Senso rs
No cutting,
weldin g, or
drilling for
a fast and
inexpensive
installation
FST1, FST2, FST3 Transd ucers
FEATURES
Wide range of measurable uids, including water, brine, raw sewage, ethylene
glycol, glycerin, and more...exibility in commercial and industrial applications
Bidirectional ow measurement...can measure forward ow, reverse ow, and
net total
No contact with uid...safe from fouling and damage from system pressure
Modbus RTU and BAcnet/IP communications available...easy integration with
existing data collection systems
Compact, rugged aluminum housing...long service in harsh environments
Digital LCD...easy to read
Universal AC or DC power with clamp-on or insertion temperature sensors and
numerous measurement unit choices...lots of exibility
Factory programming included using a web-based tool at time of ordering
(www.veris.com)...save time in installation
flow
SPECIFICATIONS
System:
Velocity Range All models: Bidirectional ow; FST 1, FST2, FST3: 2 to 40 FPS (0.6 to 12.1 MPS); FST4, FST5: 1 to 40 FPS (0.3 to 12.1 MPS) Flow Accuracy FST4, FST5: 1% of reading at rates > 1 FPS (0.3 MPS); within 0.01 FPS (0.003 MPS) at lower rates FST 1, FST2, FST3, 1” and larger unit s: 1% of reading from 4- 40 FPS (1.2-12 MPS); ± 0.04 FPS (0.012 MPS) at rates < 4 FPS 91.2-12 MPS) FST1, FST2, FST3, units smaller than 1”: 1% of full scale Flow Repeatability ±0.01% of reading Flow Sensitivity 0.001 FPS (0.0003 MPS) Temperature Accuracy (Energy Versions Only) 0° to 100°C (32° to 212°F); Absolute 0.25°C (0.45°F), Dierence 0.1°C (0.18°F) Temperature Sensitivity 0.025°C (0.05°F) Temperature Repeatability ±0.05% of reading
Monitor:
Power AC: fused, 95-264VAC, 47-63 Hz at 17VA max.; DC: auto-reset fuse, 10-28VDC at 5.0W, reverse polarity and transient supression prote cted Display 2 line backlit LCD Engineering Units Rate: Gal, liter s, million gal, ft3, m3, acre-f t, oil barrels (42 gal); liquor barrels (31.5 gal), ft, m, lb, kg (User Congured) Energy Version: BTU, MBTU, MMBTU, Ton Time: Sec, min, hr, days Totalizer: Gal, liters, million gal, f t3, m3, acre-f t, oil barrels (42 gal), liquor barrels (31.5 gal), lb, kg Ambient Conditions -40° to 85°C (-4 0° to 185°F), 0-95% RH (noncondensing) Response Time (Flow) 0.3 to 30 sec, user congured, for 10% to 90% step change in ow Security Keyp ad lockout, user selec ted 4-digit password code
Transducers:
Environment IP 67 Pipe Surface Temperature FST4, FST5: -40° to 121°C (-40° to 250°F); FST1, FST2, FST3: -4 0° to 85°C (-40° to 185°F) Ambient Conditions -40° to 85°C (-4 0° to 185°F), 0-95% RH noncondensing Software Compatibility Windows® 95, Windows® 98, Windows® 2000, Windows® XP, Windows® Vista
800.354.8556
Yea r
1
Warranty
+1 503.598.4564
www.veris.com
HQ00 01789.B 01131
800.354.8556
+1 503.598.4564
DIMENSIONAL DRAWINGS
FSR Monitor
6.4”
(163 mm)
6.0”
(153 mm)
4.1”
(105 mm)
www.veris.com
C
FST1, FST2, FST3 Transducers
A
A
D
B
D
B
C
1.4”
(35 mm)
FST4, FST5 Transducer
2.7”
(67 mm)
2.9”
(74 mm)
1.6”
(40 mm)
Clamp-On RTD Temperature Sensor
Cable Diameter
0.3 “ (7 mm)
ORDERING INFORMATION
Monitors:
Typ e
FSR
1 = Flow Meter 2 = Energy/BT U
Meter
Transducers:
Pipe Type
FST
1 = ANSI pipe, 1/2 to 2” 2 = Copper pip e, 1/2 to 2” 3 = Rigid tub e, 1/2 to 2 ” *
Pipe Type
FST 020
4 = most mate rials 2” to 24” 5 = most mate rials >24”
Power
A = AC, 95-264 V D = DC
Pipe Size
A = 1/2 ” B = 3/4” C = 1” D = 1 1/4” E = 1 1/2” F = 2”
Output
K
1 = Analog 4-20mA , Modbus, frequency or temperature * 2 = 10/100 Base-T, ethernet, BACnet, Modbus, TCP-IP
Cable Length
020
= 20 ft. (6.1 m) ***
A
= greater th an 2”
Cable LengthPipe Size
(110 mm)
 0.75”
(19 mm)
2x  0.5” (13 mm)
(19 mm)
0.5 “
(13 mm)
= 20 ft. (6.1 m)
4.3”
Pipe
0.75”
2.2”
(56 mm)
(5 mm)
2.1”
(53 mm)
0.2 “
Electrical and Hazardous
MET
C US
Location Safety
E112904
Size
1/2”
3/4”
1”
1 1/4”
1 1/2”
2” (U-bolt only)
®
* Varies due to U-bolt feature
Energy/BTU Included Temp. Senso r
Temp. Sensor Cable Length
Temp. Sensor Type
X
02 = 20 ft. (6.1 m) 05 = 50 ft. (15.2 m) ** 10 = 100 ft. (30.4 m) **
* If Flow version is selected, this option includes frequency; if Energy version is selected, this option includes temperature (not frequency). ** Call for availability. † Works with most pipe materials. See website for details. ‡ Call for other length options.
A = Clamp-on RTD B = Insertion RTD
Exam ple:
Example Monitor: FSR1AK1X or FSR2DKX02A
Example Transducer: FST2C020
U-Bolt Connection
(2” Pipe Only)
Pipe
A B C D
Material
ANSI 2.46” (63 mm) 2.36” (60 mm) 2.66” (68 mm) 0.840 (22 mm)
Copper 2.46” (63 mm) 2.36” (60 mm) 3.33” (85 mm) 0.625” (16 mm)
Tubing 2.46” (63 mm) 2.28” (58 mm) 3.33” (85 mm) 0.500” (13 mm)
ANSI 2.46” (63 mm) 2.57” (66 mm) 2.66” (68 mm) 1.050” (27 mm)
Copper 2.46” (63 mm) 2.50” (64 mm) 3.56” (91 mm) 0.875” (23 mm)
Tubing 2.46” (63 mm) 2.50” (64 mm) 3.56” (91 mm) 0.750” (19 mm)
ANSI 2.46” (63 mm) 2.92” (75 mm) 2.86” (73 mm) 1.315” (34 mm)
Copper 2.46” (63 mm) 2.87” (73 mm) 3.80” (97 mm) 1.125” (29 mm)
Tubing 2.46” (63 mm) 2.75” (70 mm) 3.80” (97 mm) 1.000” (26 mm)
ANSI 2.79” (71 mm) 3.18” (81 mm) 3.14” (80 mm) 1.660” (43 mm)
Copper 2.46” (63 mm) 3.00” (77 mm) 4.04” (103 mm) 1.375” (35 mm)
Tubing 2.46” (63 mm) 3.00” (77 mm) 4.04” (103 mm) 1.250” (32 mm)
ANSI 3.02” (77 mm) 3.42” (87 mm) 3.33” (85 mm) 1.900” (49 mm)
Copper 2.71” (69 mm) 2.86” (73 mm) 4.28” (109 mm) 1.625” (42 mm)
Tubing 2.71” (69 mm) 3.31” (85 mm) 4.28” (109 mm) 1.500” (39 mm)
ANSI 3.71” (95 mm) 3.42” (87 mm) 5.50” (140 mm) 2.375” (61 mm) *
Copper 3.71” (95 mm) 3.38” (86 mm) 5.50” (140 mm) 2.125” (54 mm) *
Tubing 3.21” (82 mm) 3.85” (98 mm) 4.75” (121 mm) 2.000” (51 mm) *
ACCESSORIES
PART # DESCRIPTION
FSA001 Kit, software CD, Veris Ultrasonic, USB
FSA002 Acc, Flow, US, transducer coupling grease, 5.3 oz.
FSA003 Acc, Flow, US, kit, 200°C temperature clamp, 1k RTD,
FSA004 Acc, Flow, US, kit, 200°C temperature clamp, 1k RTD,
FSA005 Acc, Flow, US, kit, 200°C temperature clamp, 1k RTD,
FSA006 Acc, Flow, US, kit, 200°C temperature insert, 3 x 1/4,
FSA007 Acc, Flow, US,Extra heat sink grease, 4 g
FSA008 Acc, Flow, US, temperature clamp tape, 6 ft.
FSA009 Acc, Flow, US, connector, RTD replacement
FSA010 Acc, Flow, US, kit, 200°C temperature insert, 3 x 1/4,
PS24 - 7.5W Power Supply, 24VDC, 7.5W
20 ft. lead
50 ft. lead
100 ft. lead
1k RTD 20
1k RTD 50
flow
HQ00 01789.B 01131
Loading...