Veria Control B35/45 is a electronic thermostat provided with a 2-pole switch and a oor sensor to measure and control the desired oor temperature. The thermostat is intended for ush-mounting. Veria Control is equipped with a LED indicator showing standby periods (green light) and heating periods (red light).
The maximum temperature setting of the Veria Control B35 Thermostat is 35°C, which makes it ideal for controlling electrical heating mats beneath or on top of wood oors such as parquet or laminates.
The Veria Control B45 Thermostat can be used for temperatures up to 45°C, which makes it ideal for controlling electrical heating mats on top of concrete or screed oors or underneath a tile or decorative stone covering.
Operating voltage 180-250 VAC, 50/60 Hz Contact rating:
- resistive load
- inductive load
250V ~ 15A/3450W
cos ϕ = 0,3 Max. 4A Sensor NTC 15 kOhm at 25° C Sensor values:
18°C 20°C 22°C
19,7 kOhm
18,0 kOhm
16,8 kOhm Switching differential ±0,2° C Temperature range:
- Veria Control B35
- Veria Control B45
(0) 15-35° C
(0) 5-45° C
Ambient temperature range
-10º to +30° C
Frost protection (
)
15º C (B35) / 5º C (B45)
Led Indicator:
- No light
- Red light
- Green light
- Green light ashing
Thermostat off.
Heating mat/cable is active
The desired set point tempe-
rature has been reached.
Floor sensor is faulty Protection rating IP 31
Dimensions & weight 85mm x 85mm & 90 g
- 4 - - 5 -
1.1 Technical Specications
Cable specication max. 1x4mm² or 2x2,5mm²
Ball pressure temperature 75°C
Pollution degree 2 (domestic use)
Type 1C
Storage temperature -20 to +65°C
Protection class
Class II -
The product complies with the EN/IEC Standard “Automatic electrical controls for household and similar use”:
EN/IEC 60730-1 (general)
EN/IEC 60730-2-9 (thermostat)
Produced for:
Veria ApS Ulvehavevej 44 DK-7100 Vejle Denmark
Fax: +45 7488 7151 E-mail: mail@veria.dk
1. Safety Instructions
Make sure the mains supply to the thermostat is turned off before installation.
IMPORTANT:
When the thermostat is used to control a oor heating element in connection with a wooden oor or similar material, always use a oor sensor and never set the maximum oor temperature to more than 35°C.
Please also note the following:
The installation of the thermostat must be done by an authorized and qualied installer according to local regulations.
The thermostat must be connected to a power supply via an all-pole disconnection switch.
The sensor is to be considered as live voltage. Have this in mind if the sensor must be extended.
Always connect the thermostat to continuous power supply.
Do not expose the thermostat to moisture, water, dust, and excessive heat.
1.2 Safety Instructions