þ Suitable for most types of ventilators
þ Solid state switching with noise suppression
þ Can be connected to existing installation
þ LED function indication.
þ Can also be used without light as fan delay timer
Specifications :
• Power supply: 110 to 240Vac (50/60Hz)
• Maximum load: 200W (1A)
• Delay range: from 10sec. to 5min.
• Dimensions: 80x60mm (3,2” x 2,4”)
K8041
ILLUSTRATED ASSEMBLY MANUAL H8041IP-1
2
VELLEMAN Components NV
Legen Heirweg 33
9890 Gavere
Belgium Europe
www.velleman.be
www.velleman-kit.com
0.000
Assembly hints
1. Assembly (Skipping this can lead to troubles ! )
Ok, so we have your attention. These hints will help you to make this project successful. Read them carefully.
1.1 Make sure you have the right tools:
•A good quality soldering iron (2540W) with a small tip.
•Wipe it often on a wet sponge or cloth, to keep it clean; then apply solder to the
tip, to give it a wet look. This is called ‘thinning’ and will protect the tip, and enables you to make good connections. When solder rolls off the tip,
it needs cleaning.
•Thin raisin-core solder. Do not use
any flux or grease.
•A diagonal cutter to trim excess wires. To avoid injury
when cutting excess leads, hold the lead so they
cannot fly towards the eyes.
•Needle nose pliers, for bending leads, or to hold components in
place.
•Small blade and Phillips screwdrivers. A basic range is fine.
For some projects, a basic multi-meter is required, or
might be handy
1.2 Assembly Hints :
⇒ Make sure the skill level matches your experience, to avoid disappointments.
⇒ Follow the instructions carefully. Read and understand the entire step before you
perform each operation.
⇒ Perform the assembly in the correct order as stated in this manual
⇒ Position all parts on the PCB (Printed Circuit Board) as shown on the drawings.
⇒ Values on the circuit diagram are subject to changes.
⇒ Values in this assembly guide are correct*
⇒ Use the check-boxes to mark your progress.
⇒ Please read the included information on safety and customer service
* Typographical inaccuracies excluded. Always look for possible last minute manual
updates, indicated as ‘NOTE’ on a separate leaflet.
3
Assembly hints
1.3 Soldering Hints :
Mount the component against the PCB surface and carefully solder the
leads
Make sure the solder joints are cone-shaped and shiny
Trim excess leads as close as possible to the solder joint
AXIAL COMPONENTS ARE TAPED IN THE CORRECT
MOUNTING SEQUENCE !
REMOVE THEM FROM THE TAPE
ONE AT A TIME !
4
5%
4K7= ( 4 - 7 - 2 - B )
1%
4K7= ( 4 - 7 - 0 - 1 - 1 )
COLOR= 2… 5
C O D
E
KODE
COLOR= 2...5
KLEUR
CODIFI-
CATION
DES COU-
CODE
COLOUR
FARB
KODE
KODE
FARGE-
KODE
FARVE-
FÄRG
SCHEMA
VÄRI
KOODI
ORES
CODIGO
DE COL-
LEURS
I P E SF S DK N D GB F NL
CODIGO
DE CORES
CODICE
COLORE
C O D E
0 Nero Preto Negro Musta Svart Sort Sort Schwarz Black Noir Zwart 0
(*) When placing the fan timer in a
housing then see pag 12 for mounting the LED.
q C7 : 100nF/250V
7
Construction
C...
11. Fuse holder & fuse
F...
q F1 : 1A (slow)
12. Electrolytic
Capacitors.
Watch the polarity !
q C4 : 10µF
q C5 : 220µF
q C6 : 470µF/25V
13. Capacitor
q C1 : 680nF/600V
14. Terminal Blocks
q SK1 : 3P
q SK2 : 2P
8
Connection
15. Connection & operation
Note : this kit operates on mains voltage and this may
present some hazards. Disconnect the kit from the mains
!
when working on the PCB.
A - Power supply :
Connect the device to the mains (110 - 240 Vac) through connections L & N of connector SK1.
F This kit is available in various countries. Take care to use an
appropriate connection.
F The connection cables should be equipped with an appropri-
ate strain relief when mounted in a housing.
B - Connect the fan :
This kit enables you to switch on a fan together with the light.
G ATTENTION : check the wiring carefully when connecting to an
existing installation (see connection diagram p. 10).
— Connect the fan to output connector SK2.
— Connect Lx of connector SK1 to the cable linking the switch to
the light source in question (Ø1.5mm²).
— Connect the live (L) of connector SK1 with the live of the
mains.
— Connect the neutral (N) of connector SK1 to the neutral of the
mains.
Operation : The fan starts when the lights in the room are
switched on. After the lights have been extinguished, the fan will
continue its operation for 5 more minutes. This delay can be adjusted by turning potentiometer RV1.
When the lights are turned on again during the deactivation delay,
the fan timer will simply restart. The deactivation delay will restart
after the lights are extinguished.
9
Connection diagram
16. Connection diagram
N
L
N
Lx
L
L
Lx
N
Inspect the complete assembly once more
before applying power to the unit !
10
Optional housing
17. Mounting into the optional housing
This fan timer exactly fits into the box type G311 from Velleman
Components. Follow the assembly instructions below :
1. Drilling the holes :
— Mark the centre of the holes to be drilled on the front of the
bottom enclosure. (Fig. 1.0)
— You can drill the left hole with a Ø 7mm drill bit and the right
hole with a Ø 15mm bit.
Ø 15
Ø 7
FIG. 1.0
— Mark the centre of hole to be drilled in the lid for the LED clip Fig. 2.0
— Drill the hole with a Ø 4,5mm drill.
Ø 4,5mm
FIG. 2.0
F MAKE SURE THE EDGES OF THE HOLES ARE
COMPLETELY SMOOTH.
11
Optional housing
2. Mounting :
Position the PCB in the bottom half of the enclosure. (Fig. 3.0)
G ATTENTION : Solder two wires onto the PCB instead of the
LED. The LED will be mounted on top of the enclosure later
on.
Mount the LED clip into the hole of the top
enclosure, together with the LED.
See Fig. 4.0
* LED clip (optional)
FIG. 4.0
FIG. 3.0
12
Optional housing
3. Assembling :
Pay attention when connecting the two wires with the LED.
Respect the polarity! Connect the fan timer as depicted in the
wiring diagram, see pag. 10.