FireMax200TM Modular Water Heater
` Model: FM200N
• All pumps, sensors and controls
included
• Woven Ceramic Fiber Infrared Power
Burner.
• Radial solid copper fin-tube heat
exchanger for 3600 heat transfer
• Burners activated by water flow and
temperature.
• Advanced microprocessor controls
• Natural Gas or Liquid Propane 199,990
BTUH
ACCESSORIES AND OPTIONS
FEATURES AND BENEFITS
• Single point water, gas and electrical
connections
• Factory-provided pressure and
temperature relief valve
• Space saving design can be installed
below dishtables
• All waterways constructed of stainless
steel, copper and brass for corrosion
protection and clean operation
• Simple, easy maintenance through
front panel
• All stainless steel cabinet and frame
• Circulates to hot water storage tank
Printed in USA R6/05
□ Factory Authorized StartUp-(highly
recommended)
□ Wall Mount Kit
□ Water Hammer Arrester
□ Water Pressure Gauge
□ Water Pressure/Temperature Gauge
□ Water pressure reducing valve (if water
supply pressure exceeds 80psi)
□ Low Pressure water pressure reducing
valve (for dishwasher rinse)
□ Auxiliary PowerVent required for
extended flue lengths. Call factory
□ EZ Install Kit
□ Seismic Legs
(available at extra cost)
TM
or FM200L
TM
FireMax200TM – Modular Water Heater
Model: FM200NTM or FM200L
TM
Model Number
TM
FM200
Natural Gas
Pressure
WC @ Inlet
Min Max Min Max Nat LP Min Max 1" Side Top Rear
7” 10.5” 10” 14” 3.5” 7.5”
FireMax200TM/120gal 1 hour 475 gal 420 gal 390 gal 360 gal 336 gal 320 gal
BTU/Storage 2 hour 820 gal 740 gal 660 gal 600 gal 552 gal 520 gal
Firemax200TM/240gal 1 hour 600 gal 540 gal 510 gal 480 gal 456 gal 440 gal
BTU/Storage 2 hour 940 gal 860 gal 780 gal 720 gal 672 gal 640 gal
**1” from back of exhaust vent
BtuH per burner
Natural or Propane
199,990 3/4" NPT 1" NPT
LP Gas
Pressure
WC @ Inlet
Temp Rise 600F 700F 800F 900F 1000F 1100F
Output Temp 1100F 1200F 1300F 1400F 1500F 1600F
Manifold
Pressure
WC
Gas
Connection
Water
Pressure
(Flow)
40
psi
80
psi
Water
Supply
Re-circulating
To Storage Tank
Electrical
Connection
120V 1ph 6.2
Loop
amps
Clearance From
Combustible
Surface
6” L
1” R
Gas Pressure
Regulators
One each
Supplied
1” 6”**
Shipping
Weight
418 lbs
Vent Per
Local Code
Auxiliary Power
Vent
Required for
extended flue
lengths Call
factory
Contact factory if booster will be supplying dishwasher fill valves or tank heat.
Note: May be vented through the dishwasher canopy or pant-leg exhaust system per 1991
Uniform Mechanical Code Sec 916. & 917. Check with local authority
Printed in USA R 6/05