Vanguard FM200 User Manual

Job __________________________
Item No ______________________
FireMax200TM Modular Water Heater
` Model: FM200N
• Woven Fiber Power Burner
• Radial solid copper fin-tube heat exchanger for 3600 heat transfer
• Cleanable intake air filter
• Burners activated by water flow and temperature
• Advanced microprocessor controls
• Natural Gas or Liquid Propane 199,900 BTUH
ACCESSORIES AND OPTIONS
(available at additional cost)
FEATURES AND BENEFITS
• Single point water, gas and electrical connections
• Factory-provided pressure and temperature relief valve
• Space saving design can be installed below dishtables
• All waterways constructed of stainless steel, copper and brass for corrosion protection and clean operation
• Simple, easy maintenance through front panel
All stainless steel cabinet and frame
• Circulates to hot water storage tank
• All pumps, sensors and controls included
Printed in USA R06/15
EZ-Vent Kit for Venting through
dishwasher ventilation system
Factory Authorized StartUp Wall Mount Kit Water Hammer Arrester Water Pressure Gauge Water Temperature Gauge Water Pressure/Temperature Gauge High Pressure water pressure reducing
valve (needed if water supply pressure exceeds 80psi)
Low Pressure water pressure reducing
valve (for dishwasher rinse; installed after booster & before D/W rinse)
Auxiliary PowerVent required for
extended flue lengths. Call factory
Stainless Steel Legs Seismic Stainless Steel Legs EZ Install Kit Expansion Tank
TM
TM
FireMax200TM – Modular Water Heater
Model: FM200NTM or FM200L
TM
BtuH per burner
Model Number
TM
FM200
Natural Gas
Pressure
WC @ Inlet
Min M ax Min Max Nat LP Min Max 1" Side Top Rear
7” 10.5” 10” 14”
FireMax200TM/120gal 1 hour 475 gal 420 gal 390 gal 360 gal 336 gal 320 gal
BTU/Storage 2 hour 820 gal 740 gal 660 gal 600 gal 552 gal 520 gal
Firemax200TM/240gal 1 hour 600 gal 540 gal 510 gal 480 gal 456 gal 440 gal
BTU/Storage 2 hour 940 gal 860 gal 780 gal 720 gal 672 gal 640 gal
**1” from back of exhaust vent
Natural or Propane
199,900 3/4" NPT 1" NPT
LP Gas
Pressure
WC @ Inlet
Temp Rise 600F 700F 800F 900F 1000F 1100F Output Temp 1100F 1200F 1300F 1400F 1500F 1600F
Manifold Pressure
WC
2.75”
-
3.5”
Gas Connection
6.5”
-
8”
Water
Pressure
(Flow)
40
80
psi
psi
Water Supply
Re-circulating
To Storage Tank
Electrical Connection
120V 1ph 6.2
Loop
amps
Clearance From
Combustible
Surface
6” L 1” R
Gas Pressure Regulators
One each
Supplied
1” 6”**
Shipping Weight
418 lbs
Vent Per
Local Code
Auxiliary Power
Vent
Required for
extended flue
lengths Call
factory
Contact factory if booster will be supplying dishwasher fill valves or tank heat. Note: May be vented through the dishwasher canopy or pant-leg exhaust system per 1991 Uniform Mechanical Code Sec 916. & 917. Check with local authority
Printed in USA R 07/15
Loading...
+ 1 hidden pages