Vaillant electronicVED E ../7 INT II Series, VED E 18/7 INT II, VED E 21/7 INT II, VED E 24/7 INT II, VED E 27/7 INT II Installation Instructions Manual

Installation instructions
electronicVED
VED E ../7 INT II
EXP (ar)
Publisher/manufacturer Vaillant GmbH
Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18‑0 Fax +49 21 91 18‑2810 info@vaillant.de www.vaillant.de
Contents
2 Installation instructions electronicVED 0020264435_00
Contents
1 Safety .................................................................... 3
1.1 Action-related warnings ......................................... 3
1.2 Intended use.......................................................... 3
1.3 General safety information .................................... 3
1.4 Regulations (directives, laws, standards).............. 4
2 Notes on the documentation .............................. 5
2.1 Observing other applicable documents ................. 5
2.2 Storing documents................................................. 5
2.3 Validity of the instructions...................................... 5
3 Product description............................................. 5
3.1 Overview................................................................ 5
3.2 Function................................................................. 5
3.3 Information on the data plate................................. 5
3.4 CE label ................................................................. 5
4 Set-up.................................................................... 6
4.1 Checking the scope of delivery.............................. 6
4.2 Selecting an installation location ........................... 6
4.3 Installation clearances ........................................... 6
4.4 Installing the product on the wall ........................... 6
5 Installation............................................................ 8
5.1 Connecting the hot and cold water ........................ 8
5.2 Connecting the product to the electricity supply .... 9
6 Start-up ............................................................... 10
6.1 Removing air pockets from the product............... 10
6.2 Fitting the product casing..................................... 10
6.3 Checking the system's functionality..................... 11
6.4 Activating the scald protection function ............... 11
7 Handing over to the operator ........................... 11
8 Recycling and disposal..................................... 11
9 Troubleshooting ................................................ 11
9.1 Detecting and rectifying faults ............................. 11
9.2 Procuring spare parts .......................................... 12
10 Inspection and maintenance ............................ 12
11 Decommissioning.............................................. 12
11.1 Temporarily decommissioning the product.......... 12
11.2 Permanently decommissioning the product......... 12
12 Customer service............................................... 12
13 Technical data.................................................... 13
Safety 1
0020264435_00 electronicVED Installation instructions 3
1 Safety
1.1 Action-related warnings
Classification of action-related warnings
The action-related warnings are classified in accordance with the severity of the possible danger using the following warning signs and signal words:
Warning symbols and signal words
Danger!
Imminent danger to life or risk of severe personal injury
Danger!
Risk of death from electric shock
Warning.
Risk of minor personal injury
Caution.
Risk of material or environmental damage
1.2 Intended use
There is a risk of injury or death to the user or others, or of damage to the product and other property in the event of improper use or use for which it is not intended.
Vaillant electronicVED electric instantan­eous water heaters must only be used to heat up drinking water.
Vaillant electronicVED electric instantan­eous water heaters are suitable for use only in an enclosed, frost-free room in a domestic environment.
Vaillant electronicVED electric instantan­eous water heaters are not suitable for opera­tion in secondary circulation lines.
Intended use includes the following: – observance of accompanying operating,
installation and servicing instructions for the product and any other system compon­ents
– installing and fitting the product in accord-
ance with the product and system approval
– compliance with all inspection and main-
tenance conditions listed in the instruc­tions.
Intended use also covers installation in ac­cordance with the IP code.
Any other use that is not specified in these instructions, or use beyond that specified in this document shall be considered improper use. Any direct commercial or industrial use is also deemed to be improper.
Caution.
Improper use of any kind is prohibited.
1.3 General safety information
1.3.1 Risk caused by inadequate qualifications
The following work must only be carried out by competent persons who are sufficiently qualified to do so:
Set-upDismantlingInstallationStart-upInspection and maintenanceRepairDecommissioning
Observe all instructions that are included
with the product.
Proceed in accordance with current tech-
nology.
Observe all applicable directives, stand-
ards, laws and other regulations.
1.3.2 Risk of material damage caused by frost
Do not install the product in rooms prone
to frost.
1.3.3 Risk of death from electric shock
There is a risk of death from electric shock if you touch live components.
Before commencing work on the product: Disconnect the product from the power
supply by switching off all power supplies at all poles (electrical partition with a con­tact gap of at least 3 mm, e.g. fuse or cir­cuit breaker).
Secure against being switched back on
again.
Check that there is no voltage.
1 Safety
4 Installation instructions electronicVED 0020264435_00
1.3.4 Risk of death from electric shock from live lines and connections
The drinking water that is used must demon­strate a specific resistance of 900 Ω at 15 °C. Otherwise, the product must not be used.
Before installing the unit, ask your water
company to inform you about the water resistance and conductivity.
1.3.5 Risk of being scalded by hot water
The outlet temperatures at the draw-off points can be up to approx. 60 °C.
When using the product, ensure that you
do not scald yourself.
If you want to be protected from scald-
ing, set the maximum temperature of the product to 43 °C.
1.3.6 Risk of being scalded by hot water
If a solar thermal energy system is connected upstream, hot water temperatures of over 43 °C could be generated even if the scald protection function is set.
If a solar thermal energy system is connected upstream of the product, the inlet temperat­ure must be limited by including precaution­ary features in the design (e.g. a mixer valve).
Install a mixer valve to limit the inlet tem-
perature to 25 °C.
1.3.7 Risk of being burned or scalded by hot components
Only carry out work on these components
once they have cooled down.
1.3.8 Risk of material damage caused by using an unsuitable tool
Use the correct tool to tighten or loosen
threaded connections.
1.4 Regulations (directives, laws, standards)
Observe the national regulations, stand-
ards, guidelines and laws.
Notes on the documentation 2
0020264435_00 electronicVED Installation instructions 5
2 Notes on the documentation
2.1 Observing other applicable documents
You must observe all the operating and installation in-
structions included with the system components.
2.2 Storing documents
Pass these instructions and all other applicable docu-
ments on to the system operator.
2.3 Validity of the instructions
These instructions apply only to:
Product article number
VED E 18/7 INT II
0010023714
VED E 21/7 INT II
0010023715
VED E 24/7 INT II
0010023716
VED E 27/7 INT II
0010023717
3 Product description
3.1 Overview
10
9
11
12
13
8
7
6
5
4
3
2
1
1 Mains connection ter-
minal
2 Top cable duct
3 Adjustment spindle
4 Safety switch
5 Electronics
6 Temperature selector
(infinitely variable)
7 Optional space under-
neath for the mains connection terminal
8 Filter
9 Cold water connection
10 Bottom cable duct
11 Hot water connection
12 Safety overheat cut-off
device
13 Heating block
3.2 Function
The product heats up drinking water via a bare wire in the heating block using the flow-through principle.
The drinking water can be drawn from several draw-off points.
The electronics measure the temperature of the water in the cold water supply and the water volume flow. The electrical performance that is required to heat the water to the required hot water temperature is calculated using these two values. The temperature can be set to any value between 30 °C and 60 °C on the product's temperature selector.
The hot water temperature depends on:
Water inlet temperatureWater outlet volumePerformance category of the unit
If the set hot water temperature is not reached, reduce the water volume.
3.3 Information on the data plate
Symbol Meaning
The VDE GS mark confirms that the unit complies with standards and has been tested for safety.
Symbol confirming conformity with the electromagnetic com­patibility standard
Read all of the instructions.
Barcode with serial number, The 7th to 16th digits of the
serial number form the article number
3.4 CE label
The CE label shows that the products comply with the basic requirements of the applicable directives as stated on the identification plate.
The declaration of conformity can be viewed at the manufac­turer's site.