Vaillant ecoFIT pure Operating Instructions Manual

For the operator
Operating instructions
ecoFIT pure
825 - 835
GB, IE
Operating instructions
Publisher/manufacturer
Berghauser Str. 40 D-42859 Remscheid Tel. +49 21 91 18‑0 Fax +49 21 91 18‑2810 info@vaillant.de www.vaillant.de
Contents
2 Operating instructions ecoFIT pure 0020230532_02
Contents
1 Safety ............................................ 3
1.1 Action-related warnings ................. 3
1.2 Intended use .................................. 3
1.3 General safety information............. 4
2 Notes on the documentation ...... 7
2.1 Observing other applicable
documents ..................................... 7
2.2 Storing documents......................... 7
2.3 Validity of the instructions .............. 7
3 Product description..................... 7
3.1 Front view ...................................... 7
3.2 Control elements............................ 7
3.3 Displayed symbols......................... 8
3.4 Information on the identification
plate ............................................... 8
3.5 Serial number ................................ 9
3.6 CE label ......................................... 9
3.7 Benchmark..................................... 9
4 Operation.................................... 10
4.1 Operating concept ....................... 10
4.2 Basic display................................ 10
4.3 Adjustment and display levels ..... 10
4.4 Cabinet-type casing ..................... 11
4.5 Opening the isolator devices ....... 11
4.6 Starting up the product ................ 11
4.7 Switching on the product ............. 11
4.8 Setting the heating flow
temperature ................................. 11
4.9 Setting the hot water
temperature ................................. 11
4.10 Switching Comfort mode on and
off................................................. 12
4.11 Switching off the product's
functions ...................................... 12
4.12 Guaranteeing the correct filling pressure of the heating
system ......................................... 12
4.13 Protecting the heating
installation against frost ............... 13
4.14 Switching the product to
standby mode .............................. 14
5 Troubleshooting ........................ 14
5.1 Detecting and rectifying faults...... 14
5.2 Calling up (Live monitor) status
codes ........................................... 14
6 Care and maintenance .............. 14
6.1 Maintenance ................................ 14
6.2 Caring for the product .................. 14
6.3 Reading maintenance
messages .................................... 14
6.4 Checking the condensate drain
pipework and tundish................... 14
7 Decommissioning...................... 15
7.1 Temporarily decommissioning
the product................................... 15
7.2 Permanently decommissioning
the product................................... 15
8 Recycling and disposal............. 15
9 Guarantee and customer
service ........................................ 15
9.1 Guarantee.................................... 15
9.2 Customer service......................... 15
Appendix ............................................... 16
A Status codes – Overview........... 16
B Troubleshooting ........................ 16
Safety 1
0020230532_02 ecoFIT pure Operating instructions 3
1 Safety
1.1 Action-related warnings Classification of action-re-
lated warnings
The action-related warnings are classified in accordance with the severity of the pos­sible danger using the following warning signs and signal words:
Warning symbols and signal words
Danger!
Imminent danger to life or risk of severe personal injury
Danger!
Risk of death from electric shock
Warning.
Risk of minor personal injury
Caution.
Risk of material or envir­onmental damage
1.2 Intended use
There is a risk of injury or death to the user or others, or of dam­age to the product and other property in the event of im­proper use or use for which it is not intended.
The product is intended as a heat generator for closed heat-
ing installations and for hot wa­ter generation.
Intended use includes the fol­lowing:
– observance of the operating
instructions included for the product and any other system components
– compliance with all inspection
and maintenance conditions listed in the instructions.
This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervi­sion or instruction concerning use of the product in a safe way and understand the hazards in­volved. Children must not play with the product. Cleaning and user maintenance work must not be carried out by children unless they are supervised.
Any other use that is not spe­cified in these instructions, or use beyond that specified in this document shall be considered improper use. Any direct com­mercial or industrial use is also deemed to be improper.
Caution.
Improper use of any kind is prohibited.
1 Safety
4 Operating instructions ecoFIT pure 0020230532_02
1.3 General safety information
1.3.1 Installation by
competent persons only
The installation, inspection, maintenance and repair of the product, as well as the gas ratio settings, must only be carried out by a competent person.
1.3.2 Danger caused by
improper operation
Improper operation may present a danger to you and others, and cause material damage.
Carefully read the enclosed
instructions and all other ap­plicable documents, particu­larly the "Safety" section and the warnings.
Only carry out the activities
for which instructions are provided in these operating instructions.
1.3.3 Risk of death from
escaping gas
What to do if you smell gas in the building:
Avoid rooms that smell of
gas.
If possible, open doors and
windows fully and ensure adequate ventilation.
Do not use naked flames (e.g.
lighters, matches).
Do not smoke.
Do not use any electrical
switches, mains plugs, door­bells, telephones or other communication systems in the building.
If it is safe to do so, close the
emergency control valve or the main isolator.
If possible, close the gas isol-
ator cock on the product.
Warn other occupants in the
building by yelling or banging on doors or walls.
Leave the building immedi-
ately and ensure that others do not enter the building.
Notify the gas supply com-
pany or the National Grid +44 (0) 800 111999 by tele­phone once you are outside of the building.
1.3.4 Risk of death due to a blocked or leaking flue gas pipe
What to do if you smell flue gas in the property:
Open all accessible doors
and windows fully to provide ventilation.
Switch off the product.Inform a competent person.
Safety 1
0020230532_02 ecoFIT pure Operating instructions 5
1.3.5 Risk of death due to explosive and flammable materials
Do not use or store explosive
or flammable materials (e.g. petrol, paper, paint) in the in­stallation room of the product.
1.3.6 Risk of death due to changes to the product or the product environment
Never remove, bridge or
block the safety devices.
Do not tamper with any of the
safety devices.
Do not damage or remove
any seals on components.
Do not make any changes:
The product itselfto the gas, air, water and
electricity supplies
– to the entire flue gas install-
ation
– to the entire condensate
drain system
to the expansion relief valveto the drain pipeworkto constructional condi-
tions that may affect the operational reliability of the product
1.3.7 Risk of corrosion damage due to unsuitable combustion and room air
Sprays, solvents, chlorinated cleaning agents, paint, adhes­ives, ammonia compounds, dust or similar substances may lead to corrosion on the product and in the air/flue pipe.
Ensure that the supply of
combustion air is always free of fluorine, chlorine, sulphur, dust, etc.
Ensure that no chemical sub-
stances are stored at the in­stallation site.
1.3.8 Risk of material damage caused by frost
Ensure that the heating in-
stallation always remains in operation during freezing con­ditions and that all rooms are sufficiently heated.
If you cannot ensure the op-
eration, have a competent person drain the heating in­stallation.
1 Safety
6 Operating instructions ecoFIT pure 0020230532_02
1.3.9 Risk of injury and material damage due to maintenance and repairs carried out incorrectly or not carried out at all
Never attempt to carry out
maintenance work or repairs on your product yourself.
Faults and damage should
be immediately rectified by a competent person.
Adhere to the maintenance
intervals specified.
Notes on the documentation 2
0020230532_02 ecoFIT pure Operating instructions 7
2 Notes on the
documentation
2.1 Observing other applicable documents
You must observe all operating instruc-
tions enclosed with the system compon­ents.
2.2 Storing documents
Keep this manual and all other applic-
able documents safe for future use.
2.3 Validity of the instructions
These instructions apply only to:
Product article number
Article number
Gas Coun­cil Number
VUW 256/6-3 (H-GB)
0010020389
47-044-68
VUW 306/6-3 (H-GB)
0010020390
47-044-74
VUW 356/6-3 (H-GB)
0010020391
47-044-70
3 Product description
3.1 Front view
1
2
1 Control elements 2 Plate with serial
number on the rear
3.2 Control elements
50
1
2
3
1 Fault clearance
key
2 Operating but-
tons
3 Display
3.2.1 Operator control panel
50
1
9
8
7
6
2
3
4
1
5
1 Current heating
flow temperat­ure, operating mode, fault code or additional in­formation
2 Current assign-
ment of the right­hand selection button
3 Left- and right-
hand selection buttons
4
and but-
ton
5 Fault clearance
key
3 Product description
8 Operating instructions ecoFIT pure 0020230532_02
6 Maximum out-
put (only used for Austria, Germany and Switzerland)
7 Access to the
menu for addi­tional information
8 Current assign-
ment of the left­hand selection button
9 Active operating
status
3.3 Displayed symbols
Sym­bol
Meaning Explanation
Burner operating correctly
Burner on
bar
Current filling pressure of the heating system The dashed lines show the permit­ted range
– Permanently
on: Filling pressure in the permitted range
– Flashing:
Filling pres­sure outside the permitted range
Hot water gener­ation active
– Permanently
on: Draw-off mode before burner is on
– Flashing:
Burner on in draw-off mode
Heating mode active
– Permanently
on: Heating mode heat requirement
– Flashing:
Burner on in heating mode
Comfort mode active
– Permanently
on: Comfort mode active
– Flashing:
Comfort mode active, burner on
Maintenance re­quired
Information on the maintenance message in the "Live Monitor"
Sym­bol
Meaning Explanation
Summer mode active Heating mode is switched off
Burner anti-cyc­ling time is active
To avoid the need for frequent switching on and off (increases the product's working life).
F. X X
Fault in the product
Appears instead of the basic display, may be an explanatory plain text display.
3.4 Information on the identification plate
The identification plate is mounted on the underside of the product in the factory.
The identification plate keeps record of the country in which the product is to be installed.
Information on the identi­fication plate
Meaning
Barcode with serial number
Serial number For quality control purposes;
3rd and 4th digits = year of production For quality control purposes; 5th and 6th digits = week of production For identification purposes; 7th to 16th digits = product article number For quality control purposes; 17th to 20th digits = place of manufacture
ecoFIT pure Product designation
2H, G20 – 2 kPa (20 mbar)
Factory setting for type of gas and gas connection pressure
Cat. Unit category
Product description 3
0020230532_02 ecoFIT pure Operating instructions 9
Information on the identi­fication plate
Meaning
Condensing technology
Efficiency class of the boiler in accordance with EC Dir­ective 92/42/EEC
Type: Xx3(x) Permissible flue gas connec-
tions
PMS Maximum water pressure in
heating mode
PMW Maximum water pressure in
hot water handling mode
V/Hz Electrical connection
W Max. electrical power con-
sumption
IP Level of protection
Heating mode
Hot water generation
Pn Nominal heat output range
in heating mode
Pnc Nominal heat output range
in heating mode (condensing technology)
P Nominal heat output range
in hot water handling mode
Qn Nominal heating load range
in heating mode
Qnw Nominal heating load range
in hot water handling mode
T
max.
Max. flow temperature
NOx NOx class for the product
Code (DSN) Specific product code
Read the instructions.
GC no. Gas council number
3.5 Serial number
The serial number is located on a plastic plate at the bottom of the front casing.
3.6 CE label
The CE label shows that the products comply with the basic requirements of the applicable directives as stated on the iden­tification plate.
The declaration of conformity can be viewed at the manufacturer's site.
3.7 Benchmark
Vaillant is a licensed member of the Benchmark Scheme which aims to im­prove the standards of installation and commissioning of domestic heating and hot water systems in the UK and to en­courage regular servicing to optimise safety, efficiency and performance.
Benchmark is managed and promoted by the Heating and Hotwater Industry Council. For more information visit www.benchmark.org.uk.
Please ensure that the installer has fully
completed the Benchmark Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear ex­planation of its operation. The installer is legally required to complete a com­missioning checklist as a means of complying with the appropriate Build­ing Regulations (England and Wales).
All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme. A Building Regulations Compliance Certi­ficate will then be issued to the customer
4 Operation
10 Operating instructions ecoFIT pure 0020230532_02
who should, on receipt, write the Notifica­tion Number on the Benchmark Checklist.
This product should be serviced regularly to optimise its safety, efficiency and per­formance. The service engineer should complete the relevant Service Record on the Benchmark Checklist after each ser­vice.
The Benchmark Checklist will be required in the event of any warranty.
4 Operation
4.1 Operating concept
Op­erator control element
Function
– Setting the hot water temperat-
ure
– Cancelling the activation of an
operating mode
– Cancelling a change to a set
value
– Going one selection level
higher
– Setting the heating flow tem-
perature
Reading the system pressureActivating the comfort modeActivating the operating modeConfirm settingGoing one selection level lower
+ at the same time
– Calling up the menu
or
– Reducing or increasing the set
value
– Scrolling through menu entries
The current function of the and but­tons is shown in the display.
Adjustable values are always displayed as flashing.
You must always confirm a change to a value. Only then is the new setting saved.
You can press to cancel a procedure at any time.
4.2 Basic display
50
The basic display shows the current condi­tion of the product. If you press a selection button, the activated function is displayed in the display.
The functions that are available depend on whether a controller is connected to the product.
You can switch back to the basic display by:
Pressing to exit the selection levelsNot pressing any button for longer than
15 minutes.
If there is an error message present, the basic displays switches to the error mes­sage.
4.3 Adjustment and display levels
The product has two adjustment and display levels.
The end user level contains information and setting options that you require as the end user.
The installer level is reserved for the com­petent person. It is protected by a code. Only competent persons may change any settings in the installer level.
Operation 4
0020230532_02 ecoFIT pure Operating instructions 11
4.4 Cabinet-type casing
Enclosing the product in cabinet-type cas­ing requires compliance with the applic­able design instructions.
If you require cabinet-type casing for your product, consult a heating specialist com­pany. Never, under any circumstances, enclose the product yourself.
4.5 Opening the isolator devices
1. Ask the competent person who in­stalled the product to explain to you where these isolator devices are loc­ated and how to handle them.
2. Open the gas isolator cock fully.
3. Open the service valves in the heating installation's flow and return.
4. Open the cold water stop valve.
4.6 Starting up the product
Only start up the product once the cas-
ing has been completely closed.
4.7 Switching on the product
Switch on the product via the main
switch installed on-site.
4.8 Setting the heating flow
temperature
1. Press ( ).
The target value of the heating flow
temperature appears on the display.
Note
The competent person may have adjusted the maximum possible temperature.
Conditions: No controller connected
Use or to set the required heating
flow temperature.
Confirm by pressing .
Conditions: Controller connected
Set the maximum possible heating flow
temperature on the product.
Confirm by pressing .Set the required heating flow temperat-
ure on the controller (Controller oper­ating instructions).
4.9 Setting the hot water temperature
Warning. Risk of being scalded by hot water.
To protect against Legionella, the hot water can be heated up to above 60 °C at pre-defined times.
Have a competent person
inform you about the meas­ures that should be taken to protect against Legionella in your system.
1. Press ( ).
The set hot water temperature
flashes in the display.
Conditions: No controller connected
Change the hot water temperature by
pressing or .
Confirm by pressing .
Conditions: Controller connected
Use to set the maximum possible hot
water temperature on the product.
Confirm by pressing .Set the required hot water temperature
on the controller (Controller operating instructions).
4 Operation
12 Operating instructions ecoFIT pure 0020230532_02
4.10 Switching Comfort mode on and off
Note
Comfort mode immediately sup­plies hot water at the required tem­perature, without you having to wait for the water to heat up.
1. Press ( ).
2. Press ( ).
Comf. on or Comf. off are shown
flashing in the display.
3. Activate or deactivate Comfort mode
by pressing or .
4. Press to confirm this change.
When you have activated Comfort
mode, the symbol appears in the basic display. When you have deac­tivated Comfort mode, the " " sym­bol goes out in the basic display.
4.11 Switching off the product's functions
4.11.1 Switching off heating mode
(Summer mode)
1. To switch off heating mode without
switching off the hot water generation, press ( ).
The value of the heating flow tem-
perature appears in the display.
2. Use the button to set the heating
flow temperature to Off.
3. Confirm by pressing .
Heating mode is switched off.The symbol appears in the
display.
4.12 Guaranteeing the correct filling pressure of the heating system
4.12.1 Checking the filling pressure
of the heating installation
Note
To ensure that the heating installa­tion operates smoothly, the filling pressure when the heating install­ation is cold must be between
0.10 MPa and 0.20 MPa (1.0 bar and 2.0 bar) or lie between the two dashed lines in the bar graph display.
If the heating installation extends over several storeys, a higher filling pressure may be required for the heating installation. Ask a compet­ent person for details.
In addition, the symbol appears after approx. one minute.
If the filling pressure in the heating installation falls below 0.05 MPa (0.5 bar), then the product switches off. The display alternates between the fault message F.22 and the current filling pressure.
1. Press twice.
The values for the current filling
pressure and for the minimum and maximum filling pressures appear in the display.
2. Check the filling pressure in the
display.
1 / 2
System pressure: 0.10 … 0.20 MPa (1.00 … 2.00 bar) The filling pressure is in the intended pressure range.
2 / 2
Filling pressure: < 0.08 MPa (< 0.80 bar)
Operation 4
0020230532_02 ecoFIT pure Operating instructions 13
Fill the heating installation.
(Page 13)
If you have topped up the install-
ation with sufficient heating wa­ter, the display automatically dis­appears after 20 seconds.
4.12.2 Filling the heating installation
Caution. Risk of material damage due to heating water that is ex­tremely calciferous or corros­ive or contaminated by chem­icals.
Unsuitable tap water damages the seals and diaphragms, blocks components in the product and heating installation through which the water flows and causes noise.
Only fill the heating install-
ation with suitable heating water.
1. Ask a competent person where the filling cock is located.
2. Connect the filling tap to a heating wa­ter supply in the way you were told by the competent person.
3. Open all radiator valves (thermostatic radiator valves) of the heating installa­tion.
4. Open the heating water supply.
5. Turn the filling cock on slowly and al­low water to flow in until the required filling pressure has been reached.
6. Close the heating water supply.
7. Purge all radiators.
8. Check the filling pressure in the display.
9. Top up with more water if necessary.
10. Close the filling cock.
11. Return to the basic display.
(Page 10)
4.13 Protecting the heating installation against frost
4.13.1 Frost protection function
Caution. Risk of material damage due to frost.
The frost protection function cannot guarantee flow through the entire heating installation, which means that parts of the heating installation may freeze and therefore become dam­aged.
During a period of frost, en-
sure that the heating installa­tion remains in operation and that all rooms are sufficiently heated, even when you are away.
Note
To keep the frost protection devices active, you should switch your product on and off using the controller, if one is provided.
If the heating flow temperature falls be­low 5 °C when the on/off button is on, the product comes into operation and heats the circulating water to approx. 30 °C on both the heating side and the hot water side (if available).
4.13.2 Draining the heating
installation
When the unit is switched off for an exten­ded period, frost protection can be guar­anteed by completely draining the heating installation and the product.
Consult a competent person about this.
5 Troubleshooting
14 Operating instructions ecoFIT pure 0020230532_02
4.14 Switching the product to standby mode
Press the fault clearance key for less
than three seconds.
The display shows OFF and goes
out.
The product is now in standby mode.The product's frost protection func-
tion is activated.
The main power supply is not inter-
rupted. The product continues to be supplied with power.
5 Troubleshooting
5.1 Detecting and rectifying faults
If faults occur, proceed in accordance
with the table in the appendix. Troubleshooting (Page 16)
If the fault cannot be eliminated using
the specified measures or if fault mes­sages (F.xx) occur, contact a compet­ent person.
5.2 Calling up (Live monitor) status codes
Press and at the same time.
Status codes – Overview (Page 16)
The current operating status (status
code) is shown on the display.
6 Care and maintenance
6.1 Maintenance
An annual inspection of the product carried out by a competent person is a prerequis­ite for ensuring that the product is perman­ently ready and safe for operation, reliable, and has a long working life.
6.2 Caring for the product
Caution. Risk of material damage caused by unsuitable clean­ing agents.
Do not use sprays, scouring
agents, detergents, solvents or cleaning agents that con­tain chlorine.
Clean the casing with a damp cloth and
a little solvent-free soap.
6.3 Reading maintenance messages
If the symbol is shown in the display, the product requires maintenance work.
The product is not in fault mode but contin­ues to operate.
Consult a competent person about this.If the water pressure is flashing at the
same time, simply add more heating water.
6.4 Checking the condensate drain pipework and tundish
The condensate drain pipework and tun­dish must always be penetrable.
Regularly check the condensate drain
pipework and tundish for faults and, particularly, for blockages.
You must not be able to see or feel any obstructions in the condensate drain pipe­work and tundish.
If you notice a fault, have it rectified by
a competent person.
Decommissioning 7
0020230532_02 ecoFIT pure Operating instructions 15
7 Decommissioning
7.1 Temporarily decommissioning the product
Caution. Risk of material damage due to frost.
The frost protection and mon­itoring devices are only active while the unit is connected to the power mains and switched on via the on/off button, and when the gas isolator cock is open.
Temporarily decommission
the product only if no frost is expected.
Temporarily decommission the product
only if no frost is expected.
Switch off the product via the main
switch installed on-site.
The display goes out.
When decommissioning the product
for a prolonged period (e.g. holiday), close the gas isolator cock and also, for combination products, the cold water stop valve.
7.2 Permanently decommissioning the product
Have a competent person permanently
decommission the product.
8 Recycling and disposal
The competent person who installed
your product is responsible for the dis­posal of the packaging.
If the product is identified with this
symbol:
In this case, do not dispose of the
product with the household waste.
Instead, hand in the product to a collec-
tion centre for old electrical or electronic appliances.
If the product contains batteries that are marked with this symbol, these bat­teries may contain substances that are hazardous to human health and the envir­onment.
In this case, dispose of the batteries at
a collection point for batteries.
9 Guarantee and customer
service
9.1 Guarantee
For information on the manufacturer's guarantee, you can write to the contact address that is provided on the back page.
9.2 Customer service
To ensure regular servicing, it is strongly recommended that arrangements are made for a Maintenance Agreement. Please contact Vaillant Service Solutions for further details:
Telephone: 0330 100 3461
Appendix
16 Operating instructions ecoFIT pure 0020230532_02
Appendix A Status codes – Overview
Status codes that are not listed here can be viewed in the installation instructions.
Status code
Parameter Meaning
Displays in heating mode
S.00 Heating: No heat demand Heating: No heat demand
S.02 Heating mode: Pump pre-run Heating mode: Pump pre-run
S.03 Heating mode: Ignition Heating mode: Ignition
S.04 Heating mode: Burner on Heating mode: Burner on
S.06 Heating mode: Fan overrun Heating mode: Fan overrun
S.07 Heating mode: Pump overrun Heating mode: Pump overrun
S.08 Heating mode: Anti-cycling time
Heating, remaining anti-cycling time xx mins
Displays in hot water handling mode
S.10 DHW demand Hot water requirement via flow sensor
S.14 DHW mode: Burner on DHW mode: Burner on
Displays in Comfort mode with warm start or hot water handling mode with cylinder
S.20 DHW demand Hot water requirement
S.22 DHW mode: Pump pre-run DHW mode: Pump pre-run
S.24 DHW mode: Burner on DHW mode: Burner on
Others
S.31 No heat demand: Summer mode Summer mode active
S.34 Heating mode: Frost protection Frost protection mode, frost protection
S.46 Waiting time: Measuring program
Comfort protection mode, flame loss at minimum load
B Troubleshooting
Fault Cause Measure
Product does not start up:
No hot waterHeating re-
mains cold
The gas isolator cock installed on-site and/or the gas isolator cock on the product is closed.
Open both gas isolator cocks.
The power supply in the building is dis­connected.
Check the fuse in the building. The product switches on automat­ically when the power is restored.
The product is switched off. Switch on the product ("Switch-
ing on the product" section).
The heating flow temperature is set too low or to the Heating off position, and/or the hot water temperature is set too low.
Set the heating flow temperat­ure and hot water temperature ( "Setting the heating flow temper­ature" section/"Setting the hot water temperature" section).
Appendix
0020230532_02 ecoFIT pure Operating instructions 17
Fault Cause Measure
Product does not start up:
No hot waterHeating re-
mains cold
The system pressure is insufficient. Low water pressure in the heating in­stallation (fault message: F.22).
Fill the heating installation ( "Filling the heating installation" section).
There is air in the heating installation. Have your competent person
purge the heating installation.
After three unsuccessful attempts to ignite the flame, the product switches to fault mode (fault message: F.28).
Press the fault clearance key for one second. The product makes another attempt to ignite the flame. If you have been unable to elim­inate the ignition fault after three fault clearance attempts, consult a competent person.
Hot water gener­ation functioning correctly; heating does not start up.
The external controller is not set cor­rectly.
Set the external controller cor­rectly (Controller operating in­structions).