Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Display Symbols Measurement Operation A. DC Voltage Measurement B. AC Voltage Measurement C. DC Current Measurement D. AC Current Measurement E. Measuring Resistance F. Inductance Measurement G. Capacitance Measurement H. Temperature Measurement I. Measuring Diodes & Continuity Sleep Mode Turning on the Auto Display Backlight General Specifications Accuracy Specifications A. DC Voltage B. AC Voltage C. DC Current D. AC Current E. Resistance Test F. Inductance G. Capacitance H. Temperature I. Diodes and Continuity Test
Table of Contents
3
10
4
11
13 13
15 16
17 19
20 21 23
27 27
28 29
29 29
30 30 31 31 31
5 6 8 9
24
32 32
Model UT50D: OPERATING MANUAL
33 33
33 34
Maintenance A. General Service B. Replacing the Battery C. Replacing the Fuses
Model UT50D: OPERATING MANUAL
2
Digital Multimeters Model UT50D (hereafter referred to as “the Meter”) is a 3 1/2 digits with steady operations, fashionable structure and highly reliable hand-held measuring instrument. The Meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. The Meter not only can measure AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Temperature, Inductance, Diodes and Continuity, but also has Data Hold, Full Icon Display and Sleep Mode features.
The Meter adopted advanced “co-injection” technique in order to provide sufficient insulation and anti-shaking. In addition, the Automatic Display Backlight feature enables user to work in a dim condition.
Warning To avoid electric shock or personal injury, read the “Safety Information” and “Rules for Safety Operation” carefully before using the Meter.
Model UT50D: OPERATING MANUAL
3
1 English Operating Manual 1 piece 2 Test Lead 1 pair 3 Test Clip 1 piece 4 Point Contact Temperature Probe 5 9V Battery (NEDA 1604, 6F22 or 009P) (installed inside the Meter)
1 piece 1 piece
Item
Description
Qty
In the event you find any missing or damage, please contact your dealer immediately.
4
Model UT50D: OPERATING MANUAL
Safety Information
This Meter complies with the standards IEC61010: in pollution degree 2, overvoltage category (CAT. II 1000V, CAT. III 600V) and double insulation.
CA T. II: Local level, appliance, POR TABLE EQUIPMENT etc., with smaller transient voltage overvoltages than CAT. III CAT. III: Distribution level, fixed installation, with smaller transient overvoltages than CAT. IV
Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired.
In this manual, a Warning identifies conditions and actions that pose hazards to the user, or may damage the Meter or the equipment under test.
A Note identifies the information that user should pay attention on.
International electrical symbols used on the Meter and in this Operating Manual are explained on page 8.
5
Model UT50D: OPERATING MANUAL
Rules For Safe Operation (1)
Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Pay attention to the insulation around the connectors. Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity . Replace damaged test leads with identical model number or electrical specifications before using the Meter. Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and grounding. The rotary switch should be placed in the right position and no any changeover of range shall be made during measurement is conducted to prevent damage of the Meter. When the Meter working at an effective voltage over 60V in DC or 30V rms in AC, special care should be taken for there is danger of electric shock. Use the proper terminals, function, and range for your measurements. Do not use or store the Meter in an environment of high temperature, humidity, explosive, inflammable and strong magnetic field. The performance of the Meter may deteriorate after dampened. When using the test leads, keep your fingers behind the finger guards.
6
Warning To avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or to the equipment under test, adhere to the following rules:
l
l
l
l
l
l l
l
Model UT50D: OPERATING MANUAL
Rules For Safe Operation (2)
Disconnect circuit power and discharge all high
-voltage capacitors before testing resistance, continuity, diodes, capacitance or current. Before measuring current, check the Meter’s fuses and turn off power to the circuit before connecting the Meter to the circuit. Replace the battery as soon as the battery indicator appears. With a low battery, the Meter might produce false readings that can lead to electric shock and personal injury. Remove test leads, test clips and temperature probe from the Meter and turn the Meter power off before opening the Meter case. When servicing the Meter, use only the same model number or identical electrical specifications replacement parts. The internal circuit of the Meter shall not be altered at will to avoid damage of the Meter and any accident. Soft cloth and mild detergent should be used to clean the surface of the Meter when servicing. No abrasive and solvent should be used to prevent the surface of the Meter from corrosion, damage and accident. The Meter is suitable for indoor use. Turn the Meter power off when it is not in use and take out the battery when not using for a long time. Constantly check the battery as it may leak when it has been using for some time, replace the battery as soon as leaking appears. A leaking battery will damage the Meter.
l
l
l
l
l
l
l
l l
l
7
Model UT50D: OPERATING MANUAL
International Electrical Symbols
AC (Alternating Current). DC (Direct Current). Grounding. Double Insulated. Deficiency of Built-In Battery. Warning. Refer to the Operating Manual.
Conforms to Standards of European Union.
Diode. AC or DC.
Fuse. Continuity Test.
Model UT50D: OPERATING MANUAL
8
9
(figure 1)
The Meter Structure (see figure 1)
1. LCD Display
2. Data Hold Button.
3. Rotary Switch
4. Other Input Terminals
5. COM Input Terminal
6. 20A Input Terminal
7. mA Input terminal
8. Power
Model UT50D: OPERATING MANUAL
Button Operation Performed
Turn the Meter on and off. l Press down the POWER to turn on the Meter. l Press up the POWER to turn off the Meter.
HOLD
(Blue Button)
l Press HOLD once to enter hold mode. l Press HOLD again to exit hold mode. l In Hold mode, is displayed and the present value is shown.
POWER
(Yellow Button)
Functional Buttons
Below table indicated for information about the functional button operations
Model UT50D: OPERATING MANUAL
10
(figure 2)
Display Symbols(1) (see figure 2)
No. Symbol Meaning
1
Dangerous Voltages.
2
The battery is low.
Warning: To avoid false readings, which could lead to possible electric shock or personal injury , replace the battery as soon as the battery
indicator appears.
3
Indicator for AC voltage or current.The displayed value is the mean value.
4
Indicates negative reading.
5
Test of diode.
6
Data hold is active.
7
The continuity buzzer is on.
8
Centigrade temperature
o
C
o
F
9
Fahrenheit temperature
10
V: Volts. The unit of voltage. mV: Millivolt. 1 x 10-3 or 0.001 volts.
mV, V
11
Model UT50D: OPERATING MANUAL
11