USER GUIDE & SER V ICE MANU AL
SAFETY • INST ALLA TION & I NTEGRA TION • OPERA TI NG I N STR U CTIONS • MAINTENANCE • SER V I CE
RIGHT PR ODUCT . R I GHT PLA C E. RIGHT TEMPERA T URE. SINCE 1962.
1000 Series • 1224FZR • 24" Con v ertible F r eezer
USER GUID E
u - l i n e. c o m
Contents
SAFETY • INSTALLATION & INTEGRATION • OPERATI N G INSTRUCTIONS • MAINTENANCE • SERVICE
Intro
Safety
Safety and Warning
Disposal and Recycling
Installation
Environmental Requirements
Electrical
Cutout Dimensions
Product Dimensions
Side by Side Installation
Anti-Tip Bracket
General Installation
Grille / Plinth Installation
Door Swing
Service
Troubleshooting
Warranty
Service Extended
Wire Diagram
Product Liability
Warranty Claims
Parts
Ordering Replacement Parts
System Diagnosis Guide
Compressor Specifications
Troubleshooting Extended
Control Quick Guide
Thermistor
Defrost
Door Stop
Door Adjust
Free Standing Kit
Operating Instructions
First Use
Control Operation
Sabbath Mode
Airflow and Product Loading
Maintenance
Cleaning
Cleaning Condenser
Extended Non-Use
Remove Fan and Cover
USER GUIDE
u- li n e . c om
WEL C OME T O U-LINE
C o ngr a tulati ons on y o ur U-Lin e pu rch a s e . Y o u r p r oduc t com e s fr om a c o mpa n y wi th ov er fiv e deca des a n d thr ee genera ti ons
o f p r e m i u m mo d u lar i c e ma ki n g , r e f r i g e r a t io n , an d wi ne pre s erv a tion exp e rience . U-Line co nt in ues t o b e th e Am er ic an
lea d er , del i v e r i n g v e r s a t i l it y an d f l exi b il ity f o r mul t i p l e a p pl ic ati on s in cl udi n g resi den t i a l , ligh t commerc ia l, ou tdoor a n d m arine
use . U-Li ne’ s c o mpl e te produc t coll ec ti on in clud es modu lar Wi ne C a pt ai n
Crescent I c e Mak e rs , Glass & Solid Door R e fr igerators , Drawer Models , F r eezers , and Combo ® Models .
U-Li ne has ca pt iv a t ed those wi th a n a p prec i ati on f o r t h e fi ner things wi th ex c e pti o na l func ti ona l i t y , st yle, i n s p ir ed inno v a tio ns
and a ttenti o n to e v en the s m all e st det a il s . W e ar e known a n d r e s p ected for ou r un wa v e r i n g dedication to prod uct design ,
qua l i ty and s e lect ion. U-Line i s hea d quar ter e d in Milwauk e e , Wis c ons i n and h a s s h ipped produ c t to fiv e con t inen ts for o v er
two decades and is prou d to ha v e the opportun ity to s h ip to y o u.
PR ODU C T INFORMA T ION
L o oking for ad dition al information on y o ur product? User Guides , Qu ick R e f e r e nce Guides , CAD D r awings , Compliance
Docum e nt ation, and Product W a rr anty in formation ar e all a v ailable for r e f e r e nce and download at u-l i ne . c om.
®
Models , Be v e rage Centers , Clear I c e Machines ,
PR OPER TY D A MA GE / INJUR Y CONCERNS
In the unlik e l y e v ent property dam a ge or pers onal injury is s u s p ected r e la ted to a U-Line produc t, plea se t a k e the fol l owi n g
st eps :
1. U-Li ne Cust omer C a r e mus t be c o n tac ted i mmedi a t el y a t +1 .8 0 0 . 7 7 9 . 2 54 7.
2 . Serv i c e or r e p a i r s per f orm e d on th e u n i t w i t h ou t pri o r w r it t e n app r o v a l f r om U - L i n e is n o t perm it ted . If th e u n i t ha s been
alter e d or r e pair ed in th e field withou t pr ior written a p prov a l from U-Line , c l ai ms w i ll not be eligibl e .
SER V ICE IN FORMA T ION
Answers to Custom er F r equently Ask e d Qu estions ar e a v a i l able at u-li ne . c om un der Cu stomer C a r e or y o u ma y c o nt act our
Cu s t omer Care grou p di r e ct ly , c o nt a c t in for m at ion below.
G E N E RAL I N QU IR IE S
U-Li ne Corpora t i o n
89 00 N. 5 5th St r eet
Mil w auk e e, Wi sc ons i n 5 3 2 23 USA
Monda y - F r i d a y 8 : 0 0 am to 4:30 pm CST
T : +1. 4 1 4 .3 54 .0 300
F : +1. 4 14 .3 54 . 7 9 0 5
Ema i l: s a l e s@ u- li ne . c om
u- li ne . c om
SER V ICE & P A R T S A SSIST ANCE
Monda y - F r i d a y 8:0 0 a m to 4:30 pm CST
T : +1.8 00 .7 79 .25 4 7
F : +1. 4 1 4 . 354 .5 69 6
Ser v i c e Emai l: on li nes e rvic e@u - line . c om
P a rt s Ema i l: onli nep a rt s@ u- li ne . c om
CONNEC T WITH US
Designed, engineer ed an d ass e mbled in WI, US A
Intr od uc ti on 1
USER GUIDE
u- li n e . c om
SA FETY • I NSTALLATION & INTE GRATION • OPER ATI NG INS TRUCTIONS • MAINTENANCE • SE RVICE
Safety and Warning
Please read all inst ructi o ns bef o re inst alling,
operating, or serv icing the appliance.
U s e th is a ppl ia nc e f o r it s in ten d ed purp ose onl y an d f o l l ow
these g e neral p r ecaution s with thos e li sted th roug hout th is
gu ide:
SA FETY ALERT DEFINITIONS
Throughout this gui d e are s a f e ty it ems la beled wi th a
Dan g er, Warni ng or C a u t i o n based on the ris k type:
DANGER
!
Danger means that fai l ure to fol l ow this safet y
stat ement will result in se ve re per son al inj u ry o r
death .
WARNING
!
Warning means that fa ilure to fol l ow this safet y
statement cou l d resu lt in seriou s pers onal injury
or d e ath.
CAUTION
!
Ca ut io n mea n s t h at fail ur e t o follow this saf e ty
statement may result in minor or mod e rate
pe rs onal in ju ry , p r ope r ty or eq uipm en t dam a ge.
Safet y and Warnin g 1
USER GUIDE
u- li n e . c om
SA FETY • I NSTALLATION & INTE GRATION • OPER ATI NG INS TRUCTIONS • MAINTENANCE • SE RVICE
Disposal and Recycling
DANGER
!
RISK OF CH ILD ENTRAPMENT. Bef o r e you throw
away your old ref r igerator or freezer, take off
the d oors an d leave shelves in place so children
may not easily cli m b inside.
If the unit is being remov e d from s e rv ic e for di spos al,
check and obey a ll federal, sta t e a n d l o ca l regul ati ons
reg a rd in g the di sp os al an d recy cl i n g of r e fr ig erat i o n
appliances, and follow these steps com p letely:
1. Remove a ll consumable contents from the unit.
2. Unplug the elec tric al c o rd f r o m its s o cket.
3 . Remov e th e d o or (s )/ dra w er (s ).
Dis p osal and Re c y cli n g 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Environmental Requirements
Th is m o del is in ten d ed f o r in door/i nt eri o r ap pl ic at ion s onl y
and i s not to be us ed i n inst all ati ons t h a t are open/
exposed to natural elements.
Thi s un it is des i gn ed to op era t e betw een 5 0 ° F ( 1 0°C ) and
10 0°F (3 8°C) . H i gher ambien t t e mperat ures may reduce
th e un it ’s abil ity to rea c h lo w temperatures and/or redu ce
ice produ c tion on applicable mod e ls .
Fo r best perform a nce, keep the unit out of direct sunlig ht
and a w ay from heat generat i ng equi pment.
I n cl im at es w h ere h i gh h u m i di ty an d d e w poi n t s ar e
pres ent , c o nden sa ti on ma y ap pear on ou ts ide s urf ac es.
Thi s is c o ns ider ed n o rmal . T h e condensation wil l
evaporate when th e h u midity d r ops.
CAUTION
!
Damages caused by am bi en t tem p e r atur es of
40 °F (4 °C) or below are not co vered by the
warran ty.
E n v i ronmental Requirements 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Electrical
WARNING
!
S H O C K HA ZA RD — E l ectr ical Gr oun d ing
Required. Never att e mpt to repair or perform
maint e nance on the unit unt il t h e el ectricit y has
be en d i sconne cted.
Never rem o ve th e round g r ou ndin g pro n g from
the p l u g and never u s e a two-p r on g gro und in g
adapter.
A l te ring , cu tt ing or re mov i ng pow e r cord ,
re mov i ng power pl ug, or di rect wiri ng can cause
serious injury, fire, los s of property and/or lif e,
and wi ll v o id the warranty.
Nev e r use an extension cor d to connect power to
the unit .
A l ways k e e p you r wo rk in g are a d r y .
El ectrical inst allat i on must observe all sta t e and
local codes. This uni t requires connection to a
gr oun d ed ( t hr ee -pr o ng) , polarized receptacle
that h a s been placed by a qua lified el ectrician.
Th e u n it requ ires a grou nd ed and polar i zed 115 VA C,
60 Hz, 15A p o wer s u pply (nor mal hou s ehold cu rren t ). An
i n di vi dual, proper ly grou nded branc h ci rc ui t or ci rc ui t
breaker is recommen d ed. A G F CI (grou n d fault cir c u i t
i n terrup ter ) is u s u a lly not r e qui r ed for fi xed location
appliances and is not recommen d ed fo r you r un it becaus e
i t cou l d be pron e to nu is anc e tr ippi ng . H o wever, b e s ure
to c o ns ult you r loc a l codes .
See CUTOUT DIM E NS IONS for recomm ended re ceptacle
locat i on.
Electri c al 1
USER GUIDE
4"
(102 mm)
7"
(178 mm)
24"
(610 mm)
24-1/4"
(616 mm)
34-1/4"
(870 mm)
to
35-1/8"
(892 mm)
Preferred location
for electrical outlet
is in adjacent
cabinet.
5/8"
(16 mm)
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Cutout Dimensions
PREPARE SITE
Y o ur U- Line pr oduc t has been designed fo r either free-
s tanding or bui l t - i n inst all a t i on . W h en bu il t- in , you r un it
does n o t requ ir e additional ai r sp a c e f o r top , si d e s, or
rea r . H o w e ver , th e fron t gr il l e m u st NO T b e obs t r u c t ed,
and clearance is required for an electrical con n ec ti on in
the rear.
CAUTION
!
Uni t can NOT be inst alled be hi nd a cl o s e d cab i ne t
door.
CUTOU T DIMENSIONS
Cuto ut Dimensio ns 1
USER GUIDE
24 " (610 mm)
3-9/16
"
(91 mm)
Not Including Handle
23-1/4
"
(591 mm)
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Product Dimensions
Product Dimensio ns 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Side-by-Side Installation
Two units may be ins t alled s i d e -by-side.
Cutout widt h for a si de-by - s i de i n s t a lla ti on is the c u t o ut
di mens ion of a si ng le un it ti mes two.
No trim kit i s required. H o wever, 1/4" ( 6 mm) of s p ace
need s to be main tain ed be tween the units to ensure
un obstru cted door swing.
Unit s mus t operat e from s e p a rate, properly grounded
elec tric al recepta c l e s pl aced ac cording to ea ch unit’ s
electrical sp ecifications requirem ents.
Si de-by-Side Instal lati on with B r acket
1. Sli d e both units out s o s c rews on t o p of uni t s are eas i ly
a c c e ssi ble.
3. Pl ac e brac ket over holes a n d a t t a c h to unit wit h two
sc rews rem o ved i n step 2 us in g a T-25 Tor x dri v er .
Ti ghten sc rews fully.
4. G e nt ly p u s h un it s in to p o s i t i on . Be car e f u l not t o
entangle the el ectri c al c o rd or w ater line, i f a pplic able.
5. Re-check the l e veli ng, from front to back and side to
s i de. Ma ke any nec e ss ary adjus t ments . The uni t ’ s top
su rf ac e s h ou ld be a pprox im at ely 1/ 8" ( 3 m m ) bel o w
the c o unt e rt op.
2. Remove s c rews a s shown below.
Si de-by - Side Insta llat i on 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Anti-Tip Bracket
1. Sli d e unit out so s c rews on top of unit are e a sily
a c c e ssi ble.
2. Remove t h e two sc rew s from the opposi te s i de o f t h e
hi ng e a s s e mbl y u s i n g a T- 25 T o rx driver (see b e l o w).
NOTE: 1224 models shown with fo u r screw. 1215 models
only have thr ee sc rews, but s a m e screws are used in b o th
a ppl ic at ion s .
3. Pl ac e brac ket (pa r t #14 154 ) over holes and a tta ch t o
uni t w i t h t w o s c rews removed i n st ep 2 us ing a T-2 5
Torx dri v er. Tig h ten sc rews fully.
4. G e nt ly pus h unit i n t o posi ti on. Be c a reful not to
entangle the el ectri c al c o rd or w ater line, i f a pplic able.
5. Chec k t o be s u re the uni t i s level from front t o ba ck
and side to side. M a ke an y nec e ss ary adjustments .
Th e u n it ’ s top s urf ac e shou l d b e a pprox im at el y 1/ 8"
(3 mm) below the coun ter t op .
6. Secure brac ket into adjoining s u rfa c e.
Anti -T ip Bra c k e t 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
General Installation
LE VE LING INFO RMATION
1 . U s e a l e vel to
con f i r m t h e un it is
lev e l. Lev e l should
be placed alon g top
edge and s i de ed ge
as s h own.
2. If t h e unit i s not l e vel, a d jus t the legs on t h e corners o f
the unit as neces s a r y .
INSTALLATI ON
1. P l u g in the power/elec t ri cal c o rd.
2. G e nt ly pus h the uni t i n t o pos i ti on. Be c a reful not to
entangle the cord.
3. Re-check the l e veli ng, from front to back and side to
s i de. Ma ke any nec e ss ary adjus t ments . The uni t ’ s top
su rf ac e s h ou ld be a pprox im at ely 1/ 8" ( 3 m m ) bel o w
the c o unt e rt op.
4. Remove the i n t e ri or packi n g materi al a n d w i pe out t h e
i n s i de of the unit wit h a clea n, wa ter-da mpened c l oth.
3 . C o nf irm t h e un it is l e v e l af ter ea ch adjust ment and
repeat the previous s t eps unti l t h e unit i s l e vel.
INSTALLA TION TIP
If the room floor is higher than the f l oor i n the cutout
opening, adjust the rear legs t o a c hiev e a tota l unit rear
height of 1 / 8" (3 mm) les s th an the opening’ s rear hei g ht.
Sh or ten the un it hei g ht in th e front by a d just ing the f r ont
legs. This a llows t h e unit to be gen t ly tipped in to the
openi n g . R e adj u st t h e f r on t l e gs t o lev e l th e un it af t e r i t i s
cor r ec tl y pos i t i on ed in the opening.
General Insta llat i on 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Grille - Plinth Installation
REMO VING AND INST ALL I NG GR IL LE
WARNING
!
Di sconnect electric power to t h e unit before
remov i ng the gri lle.
When usi n g the unit, t h e gr il le (pl i nt h st rip/base
fascia ) mu st b e installed.
WARNING
!
DO NOT touch the condenser fins. The cond ens e r
fins are SHARP an d can be easily dam a g e d .
Removi ng t h e grill e
1. Dis c on nect power to the uni t.
2. Loosen the two screws (1).
3. Remove grill e (2 ) from unit .
Inst alling the grille
1. Alig n cabin e t and grille holes and s e cur e , but do not
ov er tighten gri lle sc rews (1 ).
2. Rec o nnec t power to the un it.
Gril le - Pl inth Insta llat i o n 1
USER GUIDE
Wall Wall
90
Door Swing
90
Door Swing
2-1/8" Min.
(54 mm)
1/4" Min.
(6 mm)
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Door Swing
Unit s ha ve a zero c l ea ra nc e for the door to open 90°,
when inst al led adja cent t o c a binets .
Stainless Steel and bl ack and white m o dels require 2-1/8"
(5 4 mm) door clea rance t o a c c o mmodat e the handle i f
ins tal led next to a w a ll .
Integrat ed model s require 1/ 4" (6 m m ) c l e a ra nc e i f
ins tal led next to a w a ll . Al low for a d di tiona l s p ace for a n y
kn obs or pul l s in st al l e d on th e i n t e gr at ed pan e l/ fr am e.
Door Swi n g 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Door Stop
Y o ur U- L i ne un it wa s s h i pped to y o u wi th t h e opt i on al
90 ° p in(s ). ( M odel s that a r e 1 5 " wi de i n c l ude 1 pi n. Models
that are 2 4 " w i de inc l ude 2 pins .) The unit’s door will open
f r eel y w i t h ou t a f i x e d openi n g a n gl e li mi ta t i on . If you
would l i ke the door s t op at 90 ° foll ow t h es e ins t ruc t i o ns .
The pin is designed to stop the door at 90° und er
normal operating condit io ns. It is not desi gned
for exces s ive force . D o not u s e th e d oor to mov e
the unit in/out of t h e cutout during inst allat i on.
If your uni t is al read y un dercoun t er, it m i ght
need to be moved out/ forward t o access t h e
hing e.
1. Loc a t e the t h readed pi n.
3. On 24" models, a second pin is inclu d ed for the bottom
hi ng e. Repeat steps above for sec o nd hi ng e.
NOTE: Thread ed p i n wil l be inserted from the bottom.
4. Ca r e fu lly sl ide y o ur u n i t bac k in pla c e.
2. W i th the door betw een 0 ° ( c los e d) a n d 90 ° a n d usi n g a
3 / 32 " h e x dri v er , in st al l th e t hre aded pi n th roug h th e
hi ng e.
The pin can be rem o ved to return the doo r s w ing
back to it s original st ate by unscrewing the
threaded pin.
Do o r St op 1
USER GUIDE
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Door Adjustments
DO OR A L IGNME N T AND A D JUSTME NT
Al ig n an d a d ju st t h e door i f i t is not l e v e l or is n o t s e al in g
properly . If the door i s not sealed, the unit ma y not cool
prop erly , or ex cessiv e frost ma y for m in t h e in ter i or .
Properly aligned, the door ’ s gask et should be
fir m l y i n c o nt act wit h the cabinet all the wa y
a r o und t h e door ( n o g a ps) . C a r e f u l l y e x a m in e
the door ’ s gask et to ensure that it is fi rmly in
contac t with the cabinet. Also mak e sure the
door gask et is n o t pin c he d o n th e hing e side of
the d oor .
T O A L IGN A N D AD JUST TH E D OOR
R e mo v e grille:
R e mov e the grill e (s ee G R ILL E -PL I NTH IN ST AL LA TION
sec t ion of t h i s gu ide ) .
T O R E VE RSE THE DOO R
R e mo v e grille:
R e mov e the grill e (s ee G R ILL E -PL I NTH IN ST AL LA TION
sec t ion of t h i s gu ide) .
R e m o ve to p hi ng e and d o o r :
1. L oos en (do not r e mo v e ) top and bottom hi nge s c r e w s .
2. Ali g n door s q ua r e ly wi th c a binet.
3. Mak e s u re gas k et is f i rml y i n cont ac t wit h ca bi net a ll
the w a y a r o u nd the door ( n o ga ps) .
4. Tighten bott om hi nge s c rews .
5. Tighten top hi nge s c rew s .
REV E RS ING THE D OOR
L o cation of the unit m a y mak e it des i rable to moun t the
door on the opposite side of the cabinet.
Th e h i ng e h a r d war e will be r e mo v e d and ins t alled on the
oppos i te side of th e cab i n e t.
1. Hold door to k e e p it from f a l l ing.
2. R e mo v e top hinge from cabinet b y r e mo ving thr ee
sc r e ws . Set as ide a n d sa v e for poss ible fu tu r e u s e .
Door Adjus t m e nt s 1