INSTALL GUIDE |
® |
|
|
|
|
CLEAR ICE MODELS
CLEAR ICE COMBO MODELS
ICE COMBO MODELS
CLRCO2175 |
CO2175 |
|
|
CO1175 |
CO29 |
CLR2160 |
The Built-In Undercounter Leader Since 1962 |
U-LINE.COM |
|
|
1 Table of Contents |
|
Safety Precautions |
|
Safety Alert Definitions......................................................................................................................................... |
1 |
General Precautions .............................................................................................................................................. |
1 |
Inspect & Plan |
|
Product Registration ............................................................................................................................................. |
2 |
Product Description.............................................................................................................................................. |
2 |
Tools / Material Required .................................................................................................................................... |
2 |
Exterior Cleaning ................................................................................................................................................... |
2 |
Black and White Models:........................................................................................................................... |
2 |
Stainless Models:.......................................................................................................................................... |
2 |
Prepare Site |
|
Cut-Out Dimensions............................................................................................................................................. |
3 |
(CLR)CO21 & CO11 Series..................................................................................................................... |
3 |
CLR2160 Series ........................................................................................................................................... |
3 |
CO29 Series................................................................................................................................................. |
3 |
Product Dimensions |
|
All Models ................................................................................................................................................................ |
4 |
Door Swing Dimensions |
|
Other Site Requirements ..................................................................................................................................... |
5 |
Side-By-Side Installation............................................................................................................................. |
5 |
Power Supply ............................................................................................................................................... |
5 |
Water Supply ............................................................................................................................................... |
5 |
Drain .............................................................................................................................................................. |
5 |
Environmental Requirements ................................................................................................................... |
5 |
Standard Doors |
|
Door Alignment and Adjustment....................................................................................................................... |
6 |
Door Reversability................................................................................................................................................. |
6 |
Reversing the door ................................................................................................................................................ |
6 |
Self-Closing Doors |
|
Door Alignment and Adjustment....................................................................................................................... |
8 |
Door Reversability................................................................................................................................................. |
8 |
Reversing the door ................................................................................................................................................ |
8 |
Door Panel Installation |
|
Custom 1/4'' Thick Door Panel Insert ............................................................................................................ |
10 |
Door Panel Preparation.......................................................................................................................... |
10 |
Panel Dimensions..................................................................................................................................... |
10 |
Door Panel Installation ........................................................................................................................... |
10 |
Prepare Power Supply |
|
Electrical Specifications....................................................................................................................................... |
11 |
Receptacle Location ............................................................................................................................................ |
11 |
Prepare Plumbing |
|
Water Supply Connection ................................................................................................................................. |
12 |
Drain Connection (CLR2160 CLRCO2175)................................................................................................. |
12 |
Gravity Drain ............................................................................................................................................ |
12 |
Factory-Installed Drain Pump................................................................................................................ |
13 |
Locally-Installed Drain Pump................................................................................................................. |
14 |
Final Water Connection:.................................................................................................................................... |
14 |
Level The Unit |
|
Leveling Information............................................................................................................................................ |
15 |
Install the Unit |
|
Installation.............................................................................................................................................................. |
15 |
Relocating the Shelves............................................................................................................................. |
15 |
Installation Troubleshooting.................................................................................................................. |
16 |
2 Safety Precautions
IMPORTANT
•PLEASE READ all instructions before installing, operating, or servicing the appliance.
•Proper installation procedures must be followed when completing an installation or relocation of a unit. Consult the installation guide before any installation begins. U-Line contact information appears on the rear cover of this guide.
•This unit requires connection to a dedicated 15 Amp grounded (three-prong), polarized receptacle, installed by a qualified electrician, compliant with applicable electrical codes.
Safety Alert Definitions
Throughout this guide are safety items labeled with a Danger, Warning or Caution based on the risk type:
DANGER
Danger means that failure to follow this safety statement will result in severe personal injury or death.
WARNING
Warning means that failure to follow this safety statement could result in serious personal injury, property or equipment damage.
CAUTION
Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage.
General Precautions
Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide:
DANGER
RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside.
WARNING
SHOCK HAZARD - Electrical Grounding Required.
•Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.
•Never remove the round grounding prong from the plug and never use a two-prong grounding adaptor.
•Altering, cutting of power cord, removal of power cord, removal of power plug, or direct wiring can cause serious injury, fire and or loss of property and or life, and will void the warranty.
•Never use an extension cord to connect power to the unit.
•Always keep your working area dry.
WARNING
Install provided Anti-Tip kit on all Wine Captain Models and Beverage Centers. Serious personal injury could occur.
CAUTION
•Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges.
•If your model requires defrosting, DO NOT use an ice pick or other sharp instrument to help speed up defrosting. These instruments can puncture the inner lining or damage the cooling unit. DO NOT use any type of heater to defrost. Using a heater to speed up defrosting can cause personal injury and damage to the inner lining.
IMPORTANT
•Do not lift unit by door handle.
•Never install or operate the unit behind closed doors. Be sure front grille is free of obstruction. Obstructing free airflow can cause the unit to malfunction and will void the warranty.
•Failure to clean the condenser every six months can cause the unit to malfunction. This could void the warranty.
•Allow unit temperature to stabilize for 24 hours before use.
•Do not Block any internal Fans
Use only genuine U-Line replacement parts. Imitation parts can damage the unit, affect its operation or performance and may void the warranty.
U-Line Safety Precautions |
1 |
3 Inspect & Plan
Product Registration
You have received a carton containing your U-Line Clear Ice, Ice or Ice Combo unit with a package inside containing a Use and Care Guide, a Product Registration Card, and a water line kit. Please complete and mail the Product Registration Card or register online at www.U-LineService.com. Once your unit is installed, keep the Use and Care Guide and this Installation Guide in a safe place for future reference.
Product Description
This installation guide covers the following models.
U-CLR2160B-00 U-CLR2160B-40 U-CLR2160S-00 U-CLR2160S-01 U-CLR2160S-40 U-CLR2160S-41 U-CLR2160SOD-00 U-CLR2160SOD-01 U-CLR2160SOD-40 U-CLR2160SOD-41 U-CLR2160W-00 U-CLR2160W-40 U-CLRCO2175B-00 U-CLRCO2175B-40
Inspection
U-CLRCO2175S-00 U-CLRCO2175S-01 U-CLRCO2175S-40 U-CLRCO2175S-41 U-CO1175B-00 U-CO1175S-00 U-CO1175S-01 U-CO2175FB-00 U-CO2175FS-00 U-CO2175FS-01 U-CO2175FW-00 U-CO29B-00 U-CO29FB-00 U-CO29FWH-00
Unwrap and inspect the unit on a flat, level surface capable of supporting it’s entire weight. If necessary remove protective film from Stainless Steel models.
Tools / Material Required
•Screwdrivers — slotted and Phillips head
•1/4-inch thick door panel material and cutting tools (If installing a 1/4” Panel)
•1/4” Nut Driver
•5/16” Nut Driver
•Side Cutter
•Copper tubing cutter
•12” Level
•9/16” Open end wrench
•7/16” Open end wrench
•Pliers
•Copper tubing
CO2175 Models Only
•Full Overlay Door Panel Kit. Part number U-OL2175B (black units) U-OL2175W (white units)
A complete water hook up kit is also available for purchase from your dealer. Order U-Line Part No. WATERHOOKUP.
Exterior Cleaning
Black and White Models:
•Black and White surfaces may be cleaned with a mild detergent and warm water solution. Do not use solvent-based or abrasive cleaners. Use a soft sponge and rinse with clean water. Wipe with a soft, clean towel to prevent water spotting.
Stainless Models:
•Stainless door panels, handles and frames can discolor when exposed to chlorine gas, pool chemicals, salt water or cleaners with bleach.
•Keep your Stainless unit looking new by cleaning with a good quality all-in-one stainless steel cleaner/polish on a monthly basis. For best results use Claire Stainless Steel Polish and Cleaner, which can be purchased from U-Line Corporation (Part numbers 173348). Frequent cleaning will remove surface contamination that could lead to rust. Some installations may require cleaning on a weekly basis.
•Do not clean with steel wool or abrasive pads.
•Do not use cleaners that are not specifically intended for stainless steel on stainless surfaces (this includes glass, tile and counter cleaners).
•If any surface discolors or rust appears, clean it quickly with Bon-Ami or Barkeepers Friend Cleanser and a non-abrasive cloth. Always clean in the direction of the grain. Always finish this process with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems.
WARNING
Rust that is allowed to linger can penetrate into the surface of the stainless steel and complete removal of the rust may not be possible.
U-Line Inspect & Plan |
2 |
4 Prepare Site
Your U-Line product has been designed for either free-standing or built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed and clearance is required for an electrical connection in the rear.
IMPORTANT
•Unit can NOT be installed behind a closed cabinet door.
•If you would like to align the face of the unit with other adjacent cabinet doors, you may need to alter the wall just behind the drain connection on the unit to accommodate the drain.
Cut-Out Dimensions
(CLR)CO21 & CO11 Series
See Electrical |
|
Specifications |
24" |
for Power Supply |
|
34-1/4" |
Minimum |
to |
|
35-1/8" |
|
8"
24-1/4"
Follow the cut-out drawing. The 24-1/4" width allows 1/4" for ease in installation and removal of the unit. 24" is the cabinet depth in most installations.
CLR2160 Series
CO29 Series
Filler Panel (Not Provided by U-Line) – May BeAddedAbove or Below Unit to Enclose for a Built-In Look
Typical |
See Electrical |
|
Counter |
||
Specifications |
||
Height |
||
for Power Supply |
||
34-1/4" |
||
|
||
to |
24" |
|
35-1/8" |
Minimum |
|
Cut-Out |
|
|
Height |
|
|
28-5/8" |
|
|
to |
|
|
28-7/8" |
8" |
|
|
||
|
21-1/16" |
Follow the cut-out drawing. The 21-1/16" width allows 1/4" for ease in installation and removal of the unit. 24" is the counter depth in most installations. The unit is 24" deep including the door and handle.
IMPORTANT
It is extremely important that this unit sits on a level surface, as it does not have feet levelers. If it is not level, the ice mold will not fill evenly.
See Electrical |
|
|
Specifications |
24" |
|
for Power Supply |
||
|
34-1/4" to 35-1/8"
8"
15-1/4"
Follow the cut-out drawing The 15-1/4" width allows 1/4" for ease in installation and removal of the unit. 24" is the cabinet depth in most installations.
Prepare Site |
3 |
5 |
Product Dimensions |
|
All |
|
CLR2160 Series |
CO1175 Series |
23-1/4" * |
23-1/16”* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
34-3/16" |
|
|
34-3/16" |
||||
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3-15/16” |
|
15" |
3-13/16” |
|
24" |
Black andWhite |
STAINLESS CO1175 |
*Add 3/4”To Depth For Drain Line Clearance |
*Add 3/16” to Depth For Water Line Clearance |
|
|
23-1/4” * |
CO2175 Series |
|
23-1/16”* |
34-3/16"
34-3/16”
3-7/8” |
|
|
15" |
|
|
Stainless Steel |
3-13/16” |
24" |
*Add 3/4”To Depth For Drain Line Clearance |
|
Black andWhite |
CO1175 Series |
|
|
|
*Add 3/16”To Depth ForWater Line Clearance |
|
|
|
23-1/16”*
23-5/16" * |
|
|
34-3/16" |
34-3/16" |
|
3-13/16” |
24" |
3-13/16” |
|
24" |
Stainless Steel |
*Add 3/16”To Depth ForWater Line Clearance |
|
BLACK CO1175 |
|
*Add 3/16” to Depth For Water Line Clearance |
|
CO29 Series
23” *
28-1/2"
4-3/4”
20-13/16"
*Add 15/16”To Depth ForWater Line Clearance
CLRCO2175 Series
23-1/16”*
34-3/16"
3-13/16” |
24" |
|
Black andWhite
*Add 3/4”To Depth ForWater Line Clearance
23-1/16”*
34-3/16"
3-13/16”
24”
Stainless Steel
*Add 3/4”To Depth ForWater Line Clearance
Product Dimensions |
4 |