H-2241
AIR FRESHENER
DISPENSER
1-800-295-5510
uline.com
H-2241
DISPENSER DIAGRAM
HAMMER
SERVICE BUTTON
RESET BUTTON
METAL BRACKET
BATTERY COMPARTMENT
HOLES FOR
SCREW MOUNT
LCD
MIN BUTTON
HRS BUTTON
DAY BUTTON
ON / OFF SWITCH
TEST SWITCH
PRECAUTIONS
•Place dispenser away from food preparation areas.
•Avoid spraying onto plastic, varnished or painted
surfaces.
•Always replace with new alkaline batteries and
never leave dead batteries in unit.
PAGE 1 OF 2 0409 IH-2241

INSTRUCTIONS
MOUNTING THE DISPENSER
For best operation, mount the dispenser 7 to 9 feet above
the floor.
1. Place the dispenser in the desired location to be
mounted. Make a mark on the wall surface through the
two mounting holes.
2. Drill the holes at the marks and insert the anchors.
3. Place the unit on the wall and affix the screws.
4. Ensure the dispenser is mounted securely.
PROGRAMMING THE DISPENSER
1. Insert 2 "D" alkaline batteries in the battery compartment.
2. Turn the unit ON. ON/OFF switch is located on the side of
the dispenser.
NOTE: Do not insert aerosol can in the dispenser yet.
3. Set the clock by pressing the MIN and HRS buttons. Clock
is set in Military Time.
4. Set day by pressing the DAY button repeatedly until
correct day is illuminated.
5. Dispenser is set and activated.
NOTE: Factory default is all days active.
TO DEACTIVATE PRESET DAYS
1. Press the SERVICE button four times until "Off Days" is
illuminated.
2. Press the DAY button to illuminate deactivate day of
the week.
a. Press the DAY button once to deactivate unwanted
days. Deactivated days will be displayed.
b. Press the DAY button twice to skip the active days.
c. When a day is activated, to deactivate, press DAY
button once.
3. There will be a slight pause between each day as the
dispenser cycles through all the days of the week.
4. Once there is no activation on the DAY button for 5
seconds, the dispenser will save and go to the date and
time screen.
5. Active days can have specific times in which the
dispenser turns on and off.
a. Press the SERVICE button once to ON to set the time to
start each active day. Change time by using the MIN
and HRS buttons.
b. Press the SERVICE button two times to OFF, to set the
time to end each active day. Change time by using
the MIN and HRS buttons.
c. Once there is no activation on the DAY button for 5
seconds, the dispenser will save and go to the date
and time screen.
TO CHANGE THE SPRAY INTERVALS
NOTE: The default is every 15 minutes 24 hours
a day.
1. Press the SERVICE button three times to INT to set internal
time each active day. Change interval by using the MIN
button.
2. Once there is no activation on the DAY button for 5
seconds, the dispenser will save and go to the date and
time screen.
3. The dispenser is fully programmed.
4. Test spray by putting a can into the dispenser and press
the circle button underneath the ON/OFF button on the
side of the dispenser. Do not stand directly in front of the
dispenser.
BATTERY LIFE
1. Hold down the SERVICE button for 3 seconds to view the
battery life.
2. When battery life is low, a battery icon will appear on the
main screen.
3. The dispenser will hold settings for 60 seconds while
changing the batteries. Otherwise all settings will revert
back to factory settings.
CAN LIFE
1. Hold down the SERVICE button for 3 seconds and press
the SERVICE button again to view the remaining days left
in the aerosol can.
2. Each time the can is replaced, press the RESET button.