5 GHz airMAX® ac Bridge with
500 mm RF Isolated Reflector
Model: PBE-5AC-500-ISO
Introduction
Thank you for purchasing the Ubiquiti Networks®
PowerBeam®acISO. This Quick Start Guide is designed to
guide you through installation and includes warranty terms.
Package Contents
ReflectorRadomeAntenna FeedRear Housing
Mounting
Bracket
Carriage Bolts
(Qty. 4)
Nylon Insert
Lock Nuts
(Qty. 4)
TERMS OF USE: Ubiquiti radio devices must be professionally installed. Shielded Ethernet
cable and earth grounding must be used as conditions of product warranty. TOUGHCable™ is
designed for outdoor installations. It is the professional installer’s responsibility to follow local
country regulations, including operation within legal frequency channels, output power, and
Dynamic Frequency Selection (DFS) requirements.
Adjustment
Bracket
Flange Nuts
(Qty. 4)
Gigabit PoE
(24V, 0.5A) with
Mounting Bracket
Hex Bolts with Washers
(Qty. 4)
Screws with Washers
(Qty. 4)
Power CordQuick Start
Pole Clamp
(Qty. 2)
Washers
(Qty. 4)
5 GHz airMAX® ac Bridge with
500 mm RF Isolated Reflector
Model: PBE-5AC-500-ISO
Guide
Hardware Overview
Bottom View
Technology
Radome
Antenna Feed
Ethernet Port
Reset Button
Release Button
Reflector
Mounting Bracket
Alignment Pins
Rear Housing
Release Button Slot
Cable Door
Reset Button To reset to factory defaults, press and hold the
Reset button for more than 10 seconds while the device is
poweredon. Alternatively, the device may be reset remotely
via a Reset button located on the bottom of the Gigabit PoE adapter.
Release Button After you assemble the device, check the
Release button; it should be fully engaged in the Release Button
Slot of the Rear Housing. This ensures that the Antenna Feed is locked into place. If you need to remove the Antenna Feed, you
must depress the Release button first.
LEDs
Power The Power LED will light blue when the
device is connected to a power source.
Ethernet The Ethernet LED will light steady blue
when an active Ethernet connection is made and
flash when there is activity.
Signal In airOS®, you can modify the threshold
value for the wireless signal strength LEDs on the
Wireless tab under Signal LED Thresholds. Each LED
will light when the wireless signal strength is equal
to or greater than the LED’s threshold value. The
default threshold values for these LEDs are shown
below:
-73 dBm
-65 dBm
-80 dBm -94 dBm
Application Examples
The PowerBeam mounted outdoors with the Reflector
installed provides directional outdoor coverage (gain is
reflector‑dependent).
The PowerBeam mounted outdoors without the Reflector
installed provides outdoor‑to‑indoor coverage using the 3 dBi
Antenna Feed only.
Installation Requirements
• 13 mm wrench
• Shielded Category 5 (or above) cabling should be used for
all wired Ethernet connections and should be grounded
through the AC ground of the PoE.
We recommend that you protect your networks from
harmful outdoor environments and destructive ESD events
with industrial‑grade, shielded Ethernet cable from Ubiquiti
Networks. For more details, visit www.ubnt.com/toughcable
Installation
1. Align and insert the tabs of the Mounting Bracket into
the slots of the Reflector. Rotate the Mounting Bracket
counterclockwise until the alignment holes in the dish and
bracket align with each other.
2. For added support in high‑wind environments, insert four
Screws with Washers into the holes in the Reflector and
Mounting Bracket, and secure each screw with a Washer
and a Nylon Insert Lock Nut.
Mounting Bracket
Reflector
3. Line up the Alignment Pins of the Rear Housing with the
alignment holes of the Mounting Bracket. Push the Rear
Housing into the Mounting Bracket.
4. View the Reflector from the front. Ensure that the three
hooks (indicated below) of the Rear Housing are fully
engaged with the inner wall of the Reflector and locked
into place.
IMPORTANT: Before proceeding, lightly pull the Rear
Housing to confirm that it is locked into place.
5. Push in the sides of the Cable Door and detach it from the Rear Housing.
6. Attach the Antenna Feed.
a. Insert the Antenna Feed into the Rear Housing, and push
until it locks into place with a click.
b. Lightly pull the Antenna Feed to ensure that it is locked
into place and the Release Button is fully engaged.
Release
Button
Bottom View
7. Connect an Ethernet cable to the Ethernet Port of the
Antenna Feed. Then re‑attach the Cable Door to the
RearHousing.
8. Attach the Pole Clamps to the Adjustment Bracket.
a. Hold the Adjustment Bracket with its clamps facing you
and the Elevation Indicators towards the top.
b. Insert the Carriage Bolts through the holes of the
Adjustment Bracket.
c. Place the Pole Clamps on the bolts on one side of the
bracket by sliding the hole of the clamp over the bolt.
d. Place one Flange Nut on each bolt.
Elevation
Indicator