Parts SuppliedParts Supplied
Sync Link Module 1 0304-0029-01
Cable Ties 3 ?
Cable 1 ?
Mechanical SpecificationsMechanical Specifications
Dimensions: 82mm (L) x 60mm (W) x 30mm (D)
Weight: 2.5 oz
Transmit FrequenciesTransmit Frequencies
North America Frequency Hop: 903.2–914.8 MHz
Europe Single Low frequency: 869.8 MHz
Europe Single High frequency: 869.9 MHz
Setting Up the TransmitterSetting Up the Transmitter
1. Find the EAS device that is central and within
60.1m (200 feet) of the others. Designate this
device for use with the transmit module.
Wireless synchronization modules can significantly
reduce electrical interference between Sensormatic
EAS systems timed to the AC line. A module
system includes a module designated as a
transmitter and one or more modules designated
as receivers.
IMPORTANT! Ensure EAS devices can support
wireless synchronization.
IMPORTANT! The maximum distance between the
transmit module and any receive module is
approximately 60.1m (200 feet), but keep in mind
that the range depends upon the environment in
which the module is used. Many factors can limit
the range, thus it would be impossible to list them.
© Sensormatic 2002
IMPORTANT! DO NOT designate a mobile
checkout stand or use with the transmit
module. Only receive modules can be used
with mobile checkout stands.
2. Configure one module as the transmitter by
opening it and setting switch 7 to OFF (see
Table on page 3). To access the switch,
remove the holding screw and carefully
separate the top and bottom covers (the side
label serves as a hinge between the two
covers. DO NOT remove this label).
AMC-4010 SYNCHRONIZATION MODULE INSTALLATION AND SERVICE GUIDE (8200-0183-01, RE V. 03)
1 of 5
Switch 7
4. Close the module and reattach the holding
screw.
Preliminary
5. Mount the transmit module:
• As high as possible and in a location near
the designated EAS device. The length of
the cable supplied determines the distance
the module can be from the device.
IMPORTANT! Ensure the module will be
within 60.1m (200 feet) of the transmit
module.
• In such a way that the two LEDs on the
module can be readily see from below.
Note: It is recommended to mount the
module to an electrical access pole of a
checkout counter by running a tie wrap
through the two key slots on the back of
the module and then running two additional
tie warps through the tie wrap and around
the pole (see box).
Rx
Rx
Rx
Receivers (Rx) must be within
60.1m (200 feet) of the transmitter (Tx)
6. Using the cable supplied, connect the transmit
module to the expansion port of the EAS
device.
AMC-4010 SYNCHRONIZATION MODULE INSTALLATION AND SERVICE GUIDE (8200-0183-01, RE V. 03)