ZBAMB2010T
If you need assistance…
Tabletop Deactivator
Installation Guide
The AMB-2010 tabletop deactivator consists of the deactivator unit and a class 2 external power supply that plugs into an ac outlet. The power LED glows green when power is applied.
The deactivator deactivates UltraStrip II and III security labels rubbed and swirled on its surface. The deactivate field is 10cm (4 in.) square and
7.5cm (3 in.) high. Deactivation is indicated by the power LED pulsing orange and a long beep.
WARNING: Do not deactivate labels on
!
The deactivator is intended to be installed “as is” without adjustments. If adjustments are necessary, a laptop computer containing special configuration software can be connected to a jack at the rear of the deactivator.
Please observe the following safeguards before you begin installation.
audio or videotapes. The deactivate field is not magnetic media safe.
Call 1-800-241-6678 (Sensormatic / ADT Customer Response Center).
Cleaning the Deactivator
Clean exterior surface using a soft cloth moistened with warm, soapy water. Dry thoroughly. DO NOT use solvents or scouring cleanser.
Deactivation Status Indications
Status LED Tone
Power On Sequence
Ready Green
Deactivate Pulsing Orange Long Beep
Transmit Off Flashing Green
Fault Condition Red
Hard Tag Present
Flashing Green (for 10 seconds)
Continuous
Short Beep
Short Beep
Install Kit Required
Install Kit 0352-0101-01
Deactivator Assy. 1 0303-0038-01 Template, Cutout 1 8000-2699-02 Velcro, Hook, w/Adhesive .5ft 3200-0358-01 Velcro, Loop, w/Adhesive .5ft 3200-0358-02 Cable Tie, 5-1/2"L x 16"W, Nylon 3 6009-0001 Mount, Adhesive Backed, 1-1/8 sq. 3 6009-0003 Clamp, Cable, Nylon, .313D, .172MTG 2 6010-0035-10 Screw, Self-Tapping, 3.5x16 PHP 2 5810-3051-120 Label, Keep Magnetic Media Away 1 2402-1301-01 Pad, Alcohol 2 1600-0033
WARNING: Hazardous areas.
DO NOT install the deactivator where
!
© Sensormatic 2002
highly combustible or explosive products are stored or used.
WARNING: RISK OF ELECTRIC SHOCK!
Deactivator has no user-serviceable parts! DO NOT attempt to open the
deactivator.
Power Cord. The cord cannot interfere with the operation of cash drawers, conveyor belts, or with the operation, maintenance or removal of equipment.
Tools Required
§ Power drill and drill bits
§ Phillips screwdriver
§ Hand vacuum and broom.
Proper Placement
§ DO NOT install the deactivator over a metal surface. Deactivator fields interact with metal causing deactivator performance to degrade.
§ The field from the deactivator can interact with certain POS equipment. Avoid placing the deactivator too close to POS equipment.
ZBAMB2010T TABLETOP DEACTIVATOR INSTALLATION GUIDE (8200-0185-01, REV. A)
1 of 3
Page 2
Installation
Positioning the deactivator so the LED window faces away from the sales associate:
Hook and Loop Material, if used.
1. Mount the deactivator to the countertop.
Using a ZPCM mounting bracket (optional): See instructions supplied with bracket.
Using hook and loop material:
a. Mate hook and loop material, then cut
hook and loop material into two strips.
b. Remove the liner from the hook side of
each strip, then fasten a strip to the flat area on the bottom front and rear edges of the deactivator.
c. Place the deactivator in the desired
location and press down.
Using M5 machine screws:
a. Place the template supplied in the desired
mounting location and use it to drill four holes for M5 machine screws.
b. Select the appropriate length for the
screws. Screw length should be 8mm (.31 in.) plus the counter thickness.
c. From the underside of the countertop,
insert the four machine screws, mate them with the mounting holes in the bottom of the deactivator, and tighten from below.
Cable Clamp, if used.
Holes for M5 Machine Screws (4), if used.
2. Secure the power cable.
Using cable ties (not shown):
a. Remove the liner from the adhesive-
backed mount and run a tie through the hole in the mount and around the cable.
b. Fasten the cable tie securely around the
cable and remove excess.
Using the cable clamp:
a. Place the clamp around the cable near the
antenna.
b. Secure the clamp in place using a screw.
3. Connect the deactivator to the power supply and plug the power supply into an ac outlet. The deactivator will produce a brief tone at power up.
ZBAMB2010T TABLETOP DEACTIVATOR INSTALLATION GUIDE (8200-0185-01, REV. A)
2 of 3
Page 3
Optional Adjustments
To be determined.
Specifications
Power Supply
Input voltage .....................100–240 Vac, 50/60 Hz
AC line current .................. 1 Arms (max.)
Deactivator
Input voltage .....................18 Vdc
Auto synchronization......... Optional
Tone volume ..................... Adjustable, Off
Operating temperature...... 0° to 40°C
Humidity............................ 0 to 90% non-condensing
Weight (deactivator).......... 0.95kg (2.1 lbs)
Weight (power supply) ...... 0.28kg (0.6 lbs)
Declarations
Regulatory Compliance
EMC .......................................47 CFR Part 15
RSS 210 EN 300330 EN 301489
EMF........................................ VDE 0848
Safety ..................................... UL60950
EN 60 950 CE Mark
FCC COMPLIANCE: This equipment complies with Part 15 of the FCC rules for intentional radiators and Class A digital devices when installed and used in accordance with the instruction manual. Following these rules provides reasonable protection against harmful interference from equipment operated in a commercial area. This equipment should not be installed in a residential area as it can radiate radio frequency energy that could interfere with radio communications, a situation the user would have to fix at their own expense.
EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics Corporation, the party responsible for FCC compliance, could void the user's authority to operate the equipment and could create a hazardous condition.
Other Declarations
WARRANTY DISCLAIMER: Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Sensormatic Electronics Corporation reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of Sensormatic Electronics Corporation to notify any person of such revision or changes.
LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private expense and no part of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013. Unpublished - rights reserved under the Copyright Laws of the United States.
TRADEMARK NOTICE: Sensormatic, and the Sensormatic logo are trademarks or registered trademarks of Sensormatic Electronics Corporation. Other product names mentioned herein may be trademarks or registered trademarks of Sensormatic or other companies.
No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics Corporation.
MDR 11/02
ZBAMB2010T TABLETOP DEACTIVATOR INSTALLATION GUIDE (8200-0185-01, REV. A)
3 of 3
Loading...