Tyco Safety Sensormatic BIC4170 Users manual

Page 1
BIS-4170 IVS People Counter
Installation and Planning Guide
To the Installer
WARNING! Install the people counter IVS device in an air space not used for environmental air. DO
!
Contents
About the People Counter..................................... 2
Mounting Considerations....................................... 5
Installation Procedure............................................ 7
Running the Cables............................................ 8
Mounting the IVS Device ................................... 9
Connecting Video, Communications,
and Power to the IVS Device ........................... 13
Verification Test ............................................... 15
Specifications ...................................................... 22
Declarations ........................................................ 22
Appendix A: Site Survey Form .......................... 23
NOT install the IVS device in a plenum or other environmental air-handling space.
For indoor use only.
Cables placed in environmental airspace must be plenum rated unless the cables are in raceways.
To a Ceiling Tile............................................ 10
To a Ceiling T-Bar......................................... 10
To a Wall....................................................... 11
To Wood or Sheetrock Ceilings.................... 12
© 2010 Sensormatic Electronics, LLC
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
1 of 23
Page 2
About the People Counter
Mounted at ceiling heights up to 4.3m (14ft), the IVS People Counter device (Figure 1) tracks the paths of people within its field-of-view (Figure 2). The IVS device can cover an entrance up to 2.4m (8ft). The IVS device is also capable of reporting counts to a remote location through one of the following dedicated communication interfaces:
Ethernet
LDM II via RS-485
Bluetooth.
Figure 1. IVS device
Figure 2. IVS device field-of-view
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
2 of 23
Page 3
Coverage
Ceiling-mounted up to a height of 4.3m (14ft), the IVS device can cover a doorway or opening up to 2.4m (8ft) wide.
The IVS device is powered by a 48Vdc Power over the Ethernet (PoE) device.
Tracking
A floor-facing camera in the IVS device is used to determine the height of a desired target (adults), and thus to distinguish them from undesired targets such as shopping carts, pets, and children.
A count line is projected across the entrance. The line is a virtual trip wire you draw on the video image
where the “feet” of the person tracked are to be counted.
The count line can be set to trigger the count from a person crossing it while entering an area.
A person entering an area is counted as one “enter”. A person exiting an area is counted as one “exit”.
A personal computer is used to setup the IVS device and view what it detects. Downloaded or web-based
setup software displays the camera image.
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
3 of 23
Page 4
Figure 3. IVS device orientation
Hardware Features
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
4 of 23
Page 5
Mounting Considerations
Perform a site survey (Appendix A) while observing the installation site for the following considerations.
Ceiling Considerations
Composition: Sheet rock, plaster, suspended ceiling.
The IVS device can attach to any 1/4-20 thread-per-inch bolt of a customer mounting bracket.
Height: The IVS device can be mounted up to a height of 4.3m (14ft).
CAUTION: The tilt of the IVS device should follow the slope of the floor. The setup software can
adjust IVS device settings for unavoidable tilt, as long as it is less than 10 degrees of the floor slope (placeholder, TBD).
CAUTION: Mounting over stairs or highly sloped floors is not recommended (placeholder, TBD).
Access: Check for in-ceiling obstacles such as ceiling vents and fire sprinklers.
Location: Mount the IVS device in such a way that its field-of-view is centered over the entry/exit corridor.
Also, do not mount the IVS device to capture people through glass or other translucent surfaces (placeholder, TBD).
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
5 of 23
Page 6
Traffic Corral Points
Check for walls, displays and anti-theft pedestals that help corral traffic. Ideally, the traffic path should be elongated as much as possible under the IVS device.
PoE Device
The PoE device supplied with the IVS device is typically placed in computer wiring room or next to the IVS device near a convenient power outlet. The PoE comes with a 1.8m (6ft) power cable.
Other Considerations
24-hour or timed power available.
• Cable distance from IVS device to computer wiring room: DO NOT exceed a maximum of 100m (330ft).
Network switch type and ports available.
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
6 of 23
Page 7
Installation Procedure
Parts Required
• DVR for verification testing (The DVR records video data “seen” by the IVS device.)
• Cat5 cable
• IVS device
• ¼-20 threaded rod
• ¼-20 nuts (2)
Optional Parts*
?
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
7 of 23
Page 8
Running the Cables
Run a Cat5 cable from the installation site for the IVS device to the installation site for the PoE. Run another cable from the PoE to the store’s computer wiring room.
Note: Cat5 cable runs cannot exceed 100m (330ft) without using a repeater. Terminate cables following Error! Reference source not found. below.
Use plenum / non-plenum cable per local requirements.
Use pre-manufactured patch cables when available.
Leave a sufficient service loop at end of each home run.
Test all cables. Most on-site issues are cable related.
Table 1. Ethernet cable pin assignments
Pin 1
Pin Wire Color
1 WHT / ORG
2 ORG
3 WHT / GRN
4 BLU
5 WHT / BLU
6 GRN
7 WHT / BRN
8 BRN
Note: Male plug pin assignments are according to the T-568B standard. All connections are “straight through” from plug to plug, that is: pin 1 to pin 1, pin 2 to pin 2, and so on.
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
8 of 23
Page 9
Mounting the IVS Device
The IVS device can be installed at heights up to 4.3m (14ft) using one of the following methods: surface mounting bracket or recessed mounting bracket.
WARNING! Install the IVS device in an air space not used for environmental air. DO NOT install in a
plenum or other environmental air-handling space.
!
WARNING! The ceiling must support up to 5.1kg (11.2 lbs). If the ceiling cannot support the IVS
! !
Parts Supplied
Customer to supply 1/4-20 threaded rod, two 1/4-20 nuts, 2x4 wood brace, and tile hold-down clips.
device, ask building maintenance to install additional ceiling supports
WARNING! The IVS device can mount to wood or drywall ceilings with minimal disturbance to the
ceiling. It can also mount to grid ceiling structure but not to the removable tile itself
Tested to IEC 60950-1.
CAUTION: Double check all IVS device locations before drilling or cutting ceiling. This is especially
important for multiple IVS devices
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
9 of 23
Page 10
To a Ceiling Tile
1. Do the following to prepare the tile (Figure ):
Remove the ceiling tile and drill a ¼-inch hole in its center.
Cut a 2.5ft piece of wood 2x4 and drill a ¼-inch hole in its center.
Center the 2x4 above the tile structure. Then place the ¼-20 threaded rod though the hole and secure it
from above and below with two ¼-20 nuts. Ensure the rod extends only about ¼-inch below the tile.
Reinsert the ceiling tile with the threaded rod protruding through the hole in the tile.
2. Do the following to attach the IVS device (Figure ):
Loosen the two bottom screws in the IVS device and remove its top shell.
Thread the top shell to the threaded rod until it is secure against the tile.
From the underside of the tile, punch a cable access hole in the tile above the opening(s) in the top shell.
Cable Access
Traffic Direction
IVS Device
3. Run the video cable from the DVR, above the tile ceiling, and through the opening in the top shell.
4. Push the end of the Cat5 and pigtail cables down through the openings in the top shell.
To a Ceiling T-Bar
Mounting brackets enable the IVS device to mount to a suspended ceiling T-bar.
Additional Parts Required
Mounting Brackets (2): 0500-7193-01
Screws, Pan head, M3x8 (2): 5801-1051-120
Procedure
1. Loosen the two bottom screws in the IVS device and remove its top shell.
2. Cut a triangular piece off of the rubber flap to keep it from interfering with the locking screw. Repeat for the
other locking screw (Figure ).
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
10 of 23
Page 11
3. Attach two mounting brackets to the outside of the top shell with two screws as shown.
4. Maneuver the brackets into place, then tighten the two locking crews from below to secure the top shell to
the T-bar.
Locking Screws (2)
To a Wall
The RHIUCM wall mounting bracket enables the IVS device to mount to a wall.
Additional Parts Required
RHIUCM wall mounting bracket (1)
1. Loosen the two bottom screws in the IVS device and remove its top shell.
2. Mount the RHIUCM wall mount bracket supplied to the wall surface (see instructions supplied with the
bracket).
3. Place the top shell against the bracket.
4. Screws and nuts are provided for attachment. Place the top shell against the bracket and, from underneath,
insert the two screws through the holes and secure them with the nuts.
5. Run the Cat5 cable through the hole in the top of the bracket.
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
11 of 23
Page 12
6. Attach the cover to the bracket/counter assembly.
To Wood or Sheetrock Ceilings
(TBD)
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
12 of 23
Page 13
Connecting Video, Communications, and Power to the IVS Device
The PoE can be placed in the computer room (where power is readily accessible) as long as cable length from the PoE to the IVS Device does not exceed 100m (330ft). The minimum cable length is 0.5m.
1. Connect the following cables (Figure 4):
a. Connect a Cat5 cable between the host computer and the LAN input on the PoE.
b. Connect a Cat5 cable between the PoE Injector “LAN+DC” port (power and communications) and the
Ethernet connector J1 in the IVS device.
Figure 4. Connecting the PoE to the IVS Device
AC in
LAN + DC
(to IVS)
Ethernet Port J1
Power/Status LED
LAN
(to Host)
Video Out E1, E2
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
13 of 23
Page 14
2. For Video to the DVR, plug the pigtail connector of the DVR video cable to connectors E1 and E2 inside
the IVS Device.
3. Attach the bottom shell to the top shell. Tighten both screws securely.
4. Once the PoE injector into a 24-hour outlet, the IVS device will begin its boot up process. This process
takes about 40 seconds, where the Power/Status LED on the PoE module momentarily turns yellow (stand by), then green indicating that the PoE has successfully identified the IVS as a PoE compliant device.
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
14 of 23
Page 15
Verification Test
1. Check out the entire ‘IVS Engineering Test Tool Setup’ folder
from StarTeam. Locate the ‘IVS Engineering Test Tool’ icon on the desktop of your laptop.
The Test Tool is used to perform initial installation of the IVS and can be used to verify count information obtained from the IVS Device. Communications will occur via one of two communications media: Ethernet or Bluetooth (selectable via a pull down menu).
The IVS Engineering Test Tool can:
• Display the static video image “seen” by the IVS Device
• Be used to draw count lines
• Transmit count lines to the DSP
• Be used to set and maintain time
• Display and storing count data.
2. On your laptop, click the icon to open the IVS Engineering
Test Tool.
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
15 of 23
Page 16
3. From the pull down menu ‘Select COM’, select ‘Configure’ to
invoke the following ‘Input Requested’ dialog box. Enter the IP address for the IVS Device and click OK.
4. Connect a Cat5 cable from the PoE Injector “LAN” port to the
Ethernet port on your laptop.
5. From the ‘Select COM’ pull down menu, select ‘TCP/IP’. At
the bottom of the screen, click ‘Connect’.
6. Verify that the addressed IVS Device is ‘Connected’ to the
IVS Engineering Test Tool.
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
16 of 23
Page 17
7. On the side panel of the Test Tool, select the ‘Image’ tab.
Then from the ‘Get’ pull down menu, select ‘Image’. Verify on the DVR screen that the IVS Device is capturing and processing the video image.
8. Verify that the image on your display corresponds to the
image “seen” by the IVS device.
9. Select ‘New Line’ from the side panel of the Test Tool. Select
the line color from color palette and click OK.
10. Using the mouse, position the cursor to indicate the start of the line, drag it to the desired destination point, then click the cursor again. An arrow indicates the traffic direction.
• Dragging the line left to right produces an UP arrow.
• Dragging the line right to left produces a DOWN arrow.
• Traffic crossing the line in the direction of the arrow would
trigger ‘IN’ counts.
• Traffic crossing the line in the direction opposite the arrow
would trigger “OUT’ counts.
11. From the ‘Diag’ pull down menu, select ‘Verification Test’ to invoke an ‘Open’ dialog box to save the count data to a .txt file. Name and save file for later retrieval.
Note: A ‘Test In Progress’ indication at the bottom right of the Test Tool appears as shown below.
12. After the prescribed count intervals, terminate the verification test by clicking ‘Disconnect’ at the bottom of the Test Tool.
13. Retrieve .txt file for count verification against the DVR captured events.
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
17 of 23
Page 18
Adjusting the Count Line
The IVS device automatically sets the count line at the middle of its field-of-view. However, in certain situations, the line may have to be moved forward or backward.
To move the count line, do the following:
Setting the IP Address for the IVS Device
Auto addressing
Each IVS Device is automatically assigned a Static IP address of 198.168.0.1.
The best method is to disconnect all network connections from your laptop, manually assign it an IP address (such as 192.168.1.10), and then connect it directly to the IVS Device. Then each IVS Device can be assigned a unique address such as 192.168.1.7 for IVS Device 1, 192.168.1.8 for IVS Device 2, and 192.168.1.9 for IVS Device
3.
In this section, you will:
Set a static IP address on your laptop
Connect a IVS Device to your laptop
Set the IP address for the IVS Device.
Laptop Requirements
The following is required to run IVS software.
®
Use Microsoft browser.
Java Runtime JRE 1.6 update 10 (http://www.java.com video.
IE6+ or Mozilla® Firefox® 3+ web
). Required to view live
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
18 of 23
Page 19
Set a Static IP Address on Your Laptop
IMPORTANT! Set the static IP address
on your computer BEFORE connecting the IVS Device to it.
IMPORTANT! Disconnect the Ethernet
(Cat5) cable from your laptop and disable any wireless connections. No other network connections can be active during this process.
1. Disconnect the Ethernet (Cat5) cable from your laptop and disable any wireless connections.
2. From your computer desktop, click Start and select Control Panel. The Control Panel opens.
3. Double-click Network Connections. The
Network Connections window appears.
Note: The network cable connection my have a different name in some systems such as “Laptop ethernet port”.
4. Double-click Local Area Connection. The
Local Area Connection Properties dialog box appears.
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
19 of 23
Page 20
5. Select Internet Protocol (TCP/IP) and click Properties. The Internet Protocol (TCP/IP) Properties dialog box appears.
IMPORTANT! Write down the current
settings in Internet Protocol (TCP/IP) Properties dialog box so that you can re-establish them after you set the network parameters on the IVS Device.
Select Use the following IP address and
type an IP address for your computer to use. For example: 192.168.1.10.
Type 255.255.255.0 in the Subnet Mask
field.
Click OK.
6. On the Internet Protocol (TCP/IP) box, click OK. Then click the X in the top-right corner to close the window.
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
20 of 23
Page 21
Set the IP Address of the IVS Device
Once you have set the IP address on your PC and have connected the IVS Device and PoE injector to your PC, you are ready to set the IP address of the IVS Device.
Complete the following steps to set the IP address of the IVS Device:
1. Re-connect your laptop to Wi-Fi.
2. Open a web browser and in the address bar type http://192.168.1.7 CLARITY Basic Configuration screen appears.
. Press Enter. The
8. To save your changes, click Save.
CAUTION: If you change the IP address on a IVS Device
and click
Save, you will lose access to that IVS device for several seconds while the IVS device sets itself with the new IP Address. You will have to type the new IP address into the address bar of the browser and press enter to reload the application.
CAUTION: If you are assigning the IP to a new subnet, you will lose access to the IVS device until you connect the IVS device to the assigned subnet or until you modify the PC Network settings to include the new subnet.
The IVS device is now ready to be connected to the network using its new IP address and network configuration. Disconnect all cables from the IVS device and laptop.
Complete the steps in this section for each additional IVS device to be installed.
When done, set your laptop’s network configuration back to its original settings.
3. Assign the IVS Device a fixed IP address by selecting No from the DHCP Enabled field.
4. The network administrator may assign the IP address for the IVS Device. Type the IP address the IVS Device will use on your network in the IP Address field.
5. Type the Network Mask, Default Gateway, and DNS Server (optional) addresses for the network used by the IVS device.
6. Click the Link Speed drop-down arrow and select a network speed for the IVS device. If you have not been told to set the Link Speed, leave the speed set to Auto Detect.
7. If you have any of the identification information (Site ID, Site name, Device ID, Device Name), type the information into the appropriate fields.
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
21 of 23
Page 22
Specifications
Electrical
Primary Input ................................................ 48Vdc, 0.5A
Power consumption .......................................... 14W Max
Certified Limited Power Source
Network
Cabling ......................................................... Category 5e
Ethernet ................. Dual channel 100Mb Ethernet switch
Power .............................................. IEEE 802.3af Power
Addressing........................................... DHCP or Static IP
Environmental
Operating Temperature: ...........0° to 45°C (32° to 113°F)
Enclosure.....................................................IP20 Nema 1
Mechanical
Dimensions............................... 64mm x 155mm x 33mm
(2.5in x 6.1in x 1.3in)
Lens.......................................................................2.0mm
Enclosure material ................................................. Plastic
Weight ....................................................0.23kg (0.5 lbs.)
Declarations
Regulatory Compliance
EMC ....................................................... 47 CFR, Part 15
FCC COMPLIANCE: This equipment complies with Part 15 of the FCC rules for Class A digital devices when installed and used in accordance with the instruction manual. Following these rules provides reasonable protection against harmful interference from equipment operated in a commercial area. This equipment should not be installed in a residential area as it can radiate radio frequency energy that could interfere with radio communications, a situation the user would have to fix at their own expense.
CANADIAN COMPLIANCE: This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
EQUIPMENT MODIFICATION CAUTION: Equipment changes or modifications not expressly approved by Sensormatic Electronics Corporation, the party responsible for FCC compliance, could void the user's authority to operate the equipment and could create a hazardous condition.
Other Declarations
WARRANTY DISCLAIMER: Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Further, Sensormatic Electronics Corporation reserves the right to revise this publication and make changes from time to time in the content hereof without obligation of Sensormatic Electronics Corporation to notify any person of such revision or changes.
LIMITED RIGHTS NOTICE: For units of the Department of Defense, all documentation and manuals were developed at private expense and no part of it was developed using Government Funds. The restrictions governing the use and disclosure of technical data marked with this legend are set forth in the definition of “limited rights” in paragraph (a) (15) of the clause of DFARS 252.227.7013. Unpublished - rights reserved under the Copyright Laws of the United States.
TRADEMARK NOTICE: Sensormatic is a registered trademark of Sensormatic Electronics Corporation. The SD Logo (below) is a trademark of SD-3C, LLC. Other product names mentioned herein may be trademarks or registered trademarks of Sensormatic or other companies.
No part of this guide may be reproduced in any form without written permission from Sensormatic Electronics Corporation.
MDR 2/2010
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
22 of 23
Page 23
Appendix A: Site Survey Form
General Information
Customer Name Site Name and Number
Site Address
Site Telephone Number
Hours Of Operation
Local Contact Name Contact Telephone Survey Performed By Survey Date and Time
Ceiling Height IVS Device Mounting
Ceiling Composition Ceiling Slope Ceiling Access
Additional Considerations
Mon Tue Wed Thu Fri Sat Sun
Ceiling Information
Height
Door Information
Door Width Door Type Pedestals (yes/no)
Additional Considerations
Other Information
Floor Slope Distance to Head End Head-End Power? Ceiling Power? Network Switch Type Num. Ports Available
Sketch
BIS-4170 IVS PEOPLE COUNTER 8200-2702-01, REV. 4A INSTALLATION AND PLANNING GUIDE
23 of 23
Loading...