This instruction sheet covers the use of “T”–HEAD
Crimping Tools 59170, 59250, 59275, 59300,
69692–1, and 69693–1. See Figure 1. These tools
crimp:
S
PIDG* vinyl and nylon terminals and splices on
stranded copper wire sizes 26 through 14.
S
STRATO–THERM* terminals on stranded
copper wire sizes 26 through 14.
S
PIDG Insulation Restricting Nylon Terminals on
stranded copper wire sizes 26 through 14.
Reasons for reissue of this sheet are provided in
Section 9, REVISION SUMMARY.
2.DESCRIPTION
The handles of the crimping tools are color–coded to
match the color coding of the product to be applied.
The insulation adjustment indicator is used to control
crimp height of the insulation barrel. It can be set at
any of four positions corresponding to insulation
diameter.
Tools also feature a locator, quick take–up trigger, and
color code information.
The CERTI–CRIMP hand crimping tool ratchet control
ensures full crimping of the product. Once engaged,
the ratchet will not release until the handles have
been FULLY closed.
Note that tool handles and terminal, splice and cap
insulation are color coded for a given wire range as
listed in Figure 2. Crimp the color coded terminal,
splice or cap in the matching color coded portion of
the tool. For example, when using Hand Tool 59275,
yellow coded PIDG terminals and splices and red
coded pre–insulated seated splices must be crimped
in that portion of tool displaying the red and yellow
coded dots and yellow handle. See Figure 1.
2. Open crimping dies by closing handles until
ratchet releases. See Figure 1. Note, that once
ratchet is engaged, handles cannot be opened until
they are first fully closed.
4. Raise locator and place splice under locator as
shown in Figure 4. Splice window indent faces top
of tool.
5. Press quick take–up trigger and close handles
until terminal or splice is held firmly in place. Do
not deform terminal or splice wire barrel.
6. Insert stripped wire into terminal until conductor
butts against locator. See Figure 3. Insert stripped
wire into splice until conductor butts against splice
wire stop. See Figure 4.
NOTE
Donotallowwireinsulationtoenterwirebarrel.
i
7. Hold wire in position and complete crimp by
closing handles until the ratchet releases.
8. Refer to Section 6 and Figure 6 or 7 for terminal
or splice “Crimp Inspection” procedure.