Tweco 9-9436 User Manual

Manual 0-4743
82 Benning Street, West Lebanon, NH 03784 USA
(603) 298-5711 • www.thermal-dynamics.com
General Information
This kit accepts preflow, plasma, and shield gases and water from the Gas Control Module and supplies these gases to the Torch.
Supplied Parts
• Torch Valve Assembly
• Installation Instructions
Torch Valve Kit No. 9-9436
Installation Instructions
Installation
®
WARNING
Disconnect primary power at the source.
1. Mount the Valve Kit as close as possible to the Torch. The valve kit can be mounted in any convenient posi­tion, provided the outlet side (with two fittings) is closer to the torch than the inlet side (with three fittings and a control cable connector).
2. Connect the Valve Kit outlets to the torch leads as shown.
2.06 in 52 mm
3.72 in 95 mm
4.63 in
118 mm
3.34 in 85 mm
Art # A-04760
Do not remove brass plugs
Right-hand Thread:
To Torch Shield Gas fitting
Left-hand Thread:
Art # A-04761
To Torch Plasma Gas fitting
Outlet Side
© 2005 Thermadyne Corp.
April 4, 2006 1 Manual 0-4743 Rev. AA
3. Connect the gas supply lines and the control cable con­nector from the Gas Control Module to the Valve Kit as shown. Hold the check valves stationary while at­taching the gas lines.
Control Cable
Water Inlet
Shield Gas Inlet
Preflow Gas Inlet
Plasma Gas Inlet
Art # A-07028
Operation
Operation of the Torch Valve is controlled by the Gas Con­trol Module. The Torch Valve does not require any adjust­ment or calibration.
Control Connector Pinout Diagram
1
12
3: Ground
6: To SV14 (Bottom)
14
13
NOTE
2: To SV16 (Top)
5: To SV14 (Top)
4: To SV16 (Bottom)
8: To SV15 (Top)
9: To SV15 (Bottom)
Art # A-07426
Every effort has been made to provide complete and accurate information in this manual. How­ever, the publisher does not assume and hereby disclaims any liability to any party for any loss or damage caused by errors or omissions in this Manual, whether such errors result from negligence, accident, or any other cause.
7
11
10
April 4, 2006 2 Manual 0-4743 Rev. AA
Loading...