T&S EC-3101, EC-3100, EC-3106, EC-3103, EC-3102 Installation And Maintenance Instructions Manual

Installation and
Maintenance
Instructions
EC-3100 Series
ChekPoint
ELECTRONIC FAUCET DECK-MOUNT & WALL-MOUNT GOOSENECK, SPOUT & 4” CENTERSET SENSOR OPERATED
Limited One Year Warranty
T&S warrants to the original purchaser (other than for purposes of resale) that such product is free from defects in material and workmanship for a period of one (1) year from the date of purchase. During this one-year warranty period, if the product is found to be defective, T&S shall, at its options, repair and/or replace it. To obtain warranty service, products must be returned to...
T&S Brass and Bronze Works, Inc. Attn: Warranty Repair Department
2 Saddleback Cove
Travelers Rest, SC 29690
Shipping, freight, insurance, and other transportation charges of the product to T&S and the return of repaired or replaced product to the purchaser are the responsibility of the purchaser. Repair and/or replacement shall be made within a reasonable time after receipt by T&S of the returned product. This warranty does not cover Items which have received secondary fi nishing or have been altered or modifi ed after purchase, or for defects caused by physical abuse to or misuse of the product, or shipment of the products. Any express warranty not provided herein, and any remedy for Breach of Contract which might arise, is hereby excluded and disclaimed. Any implied warranties of merchantability or fi tness for a particular purpose are limited to one year in duration. Under no circumstances shall T&S be liable for loss of use or any special consequential costs, expenses or damages. Some states do not allow limitations on how long and implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. Specifi c rights under this warranty and other rights vary from state to state.
P/N: 098-016361-45 Rev.6 Date: 04-22-14 Drawn: TEH Checked: GEF 05-07-14 Approved: JHB 05-07-14
EC-3100
EC-3101
EC-3102
EC-3103
EC-3106
3
2
1
4
5
10
8
6
9
7
Exploded View
2
EC-3100
1
2
3
4
6
7
9
8
5
10
Exploded View
3
EC-3101
1
3
5
6
7
2
8
4
Exploded View
4
EC-3102
1
3
4
5
6 7
2
8
Exploded View
5
EC-3103
6
5
4
3
2
1
Exploded View
6
EC-3106
Part Number Guide
7
EC-3100 & EC-3101 Electronic Faucets
1 Aerator, Vandal Resistant B-0199-06 2 Adapter for Non-Splash Aerator 044A 3 O-Ring 006575-45 4 Angled Sensor w/ Cable 017195-45 5 Inlet Hose for use with EC-3100 1/2” NPSM-F x 1/4” NPSM-F x 18” Long 016297-45 5 Inlet Hose for use with EC-3101 1/2” NPSM-F x 3/8” NPSM-F x 30” Long 016325-45 6 Electronic Module 016647-45 7 A/C Transformer 5EF-0002 8 Manual Mixing Valve 5EF-0006 9 Supply Hose, 9/16-24 UN Female x 1/2” NPSM 5EF-0005 10 Vandal Resistant Key Q015425-45
EC-3102 & EC-3103 Electronic Faucets
1 Aerator, Vandal Resistant, 2.2 GPM 016355-45 2 Angled Sensor w/ Cable 017195-45 3 Inlet Hose, Faucet, 1/2” NPSM-F x 1/4” NPSM-F 016297-45 4 Electronic Module 016647-45 5 A/C Transformer 5EF-0002 6 Manual Mixing Valve 5EF-0006 7 Supply Hose, 9/16-24 UN Female x 1/2” NPSM 5EF-0005 8 Vandal Resistant Key Q015425-45
EC-3106 Electronic Faucet
1 ChekPoint Module (Blue) with Bypass Tee 017493-45 2 A/C Transformer 5EF-0002 3 Manual Mixing Valve 5EF-0006 4 Supply Hose, 9/16-24 UN Female x 1/2” NPSM 5EF-0005 5 VR Aerator with Key B-0199-09 6 Vandal Resistant Key Q015425-45
8
General Instructions
Important:
· ALL ELECTRICAL WIRING IS TO BE INSTALLED IN ACCORDANCE WITH NATIONAL/LOCAL CODES AND REGULA­TIONS.
· ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS.
· USE APPROPRIATE PRECAUTIONS WHILE CONNECTING TRANSFORMER TO 120 VAC POWER SOURCE.
· DO NOT PLUG TRANSFORMER INTO POWER SOURCE (RECEPTACLE) UNTIL ALL WIRING IS COMPLETED.
· FLUSH ALL WATER LINES UNTIL WATER IS CLEAR BEFORE CONNECTING FAUCET TO SUPPLY STOPS.
Tools Required For Installation of Faucets
· 8” (200mm) adjustable wrench
· 1/8” hex key wrench
· Basin wrench
· Slotted screwdriver, 3/16”
· Phillips head screwdriver, #1
· Pliers
Prior to Installation:
Prior to installing the T&S ChekPoint Series Faucet, install the items listed on next column. Also, refer to Figure 1.
· Provide electrical receptacle within
approximately 6’ from sink for plug-in transformer — 120 VAC, 2 amp service for each plug-in transformer used.
· Scrub or wash-up sink
· Drain line
· Hot and cold water supply lines
Mixing Valve
When installing the faucet with the mix­ing valve the Installation Instructions MUST be followed.
Figure 1
Deck-Mount
Wall-Mount
9
General Instructions
Installation of ChekPoint Faucets
The T&S ChekPoint Sensor Operated Faucet is a pre-tempered faucet. A mixing valve (supplied) must be used in conjunction with the faucet. Water temperature can be controlled by adjusting the mixing valve.
Install Faucet Assembly (Figures 2A, 2B, 2C and 2D)
TO MOUNT ON A SURFACE UP TO 1” (25mm) THICK
Insert faucet cable and spout shank through base gasket and then through the mount­ing hole of scrub or wash-up sink. Secure using lockwasher and nut supplied.
Note: T&S Brass does NOT supply hardware necessary for mounting the faucet on surfaces thicker than 1” (25 mm) thick.
Figure 2A
Wall-Mount
(Front View)
Figure 2B
Single Hole Deck-Mount
(Front View)
(Back View)
(Bottom View)
(Front View)
Figure 2C
4” Deck-Mount
(Bottom View)
Figure 2D
EC-3106
10
General Instructions
OPTIONAL ANTI-ROTATION FEATURE
Wall-Mount Model: EC-3101
(Figure 2D)
Note: The anti-rotation feature uses a set screw to anchor the faucet in the vertical position and is intended for use ONLY on stainless steel sinks.
Use the mounting hole diagram or fau­cet base gasket as a template by placing it in position over the faucet mounting hole. Mark the stainless steel mounting surface at the center of the small notch at the bottom of the base gasket. Drill a 9/32” (7.14 mm) diameter hole through the stainless steel mounting surface. Extend the 1/4-20 set screw installed in the back of the faucet body by unscrew­ing it (counterclockwise) with a 1/8” hex key wrench. Unscrew it far enough that it protrudes past the base gasket and into the 9/32” drilled hole. Assemble the washer and nut to secure the faucet in place.
OPTIONAL ANTI-ROTATION FEATURE
Deck-Mount Models: EC-3100 & EC-3102
(Figure 2E)
Note: The anti-rotation feature uses a pin to anchor the faucet in position and is intended for use ONLY on stainless steel sinks.
Use the mounting hole diagram or the faucet base gasket as a template by placing it in position over the faucet mounting hole. Mark the stainless steel mounting surface at the center of the small hole at the bottom of the base gasket. Drill a 5/32” (4 mm) diameter hole through the stainless steel mounting surface. Install the faucet aligning the pin with the small hole. Assemble the washer and nut to secure the faucet in place.
Note: The pin can be removed with pliers if not needed.
Figure 2D
Figure 2E
EC-3101 MOUNTING HOLE
DIAGRAM
Ø1” THRU
1 9/32”
Ø9/32” For Anti-Rotation
EC-3100 & EC-3102
MOUNTING HOLE
DIAGRAM
Ø1” THRU
Ø5/32” For Anti-Rotation
1”